Table 2.

Summary of colorimetric sensing of breath biomarkers.

Breath biomarkers Clinical correlation Related diseases Sensing probes Substrates Humidity concerns
Oxygen (O2) Oxygen consumption related to metabolism. Oxygen uptake, metabolic rate.95 Lignin95 Paper95 The sensor is capable of selectively detecting oxygen in human breath at high humidity (100%).95
Carbone dioxide (CO2) CO2 production related to metabolism. COPD (chronic obstructive pulmonary disease), asthma,96 and capnography.46, 97 pH indicators, such as mcresol purple,98 cresol red,98 phenol red,46 and thymol blue.96 Hydrophobic plastic film (ethyl cellulose) incorporated with a phase-transfer agent (tetraoctyl ammonium hydroxide)46 The colorimetric CO2 sensor showed stable performance at 37°C and 100% humidity.46
Acetone Breath acetone is correlated with blood glucose (BG) and blood ketone levels.99, 100 Diabetes99, 100 Resorcinol35, 101 Nafion membrane35, 101 The incorporated organic acids played an important role in mitigating the humidity interference to the Nafion membrane catalysts in humid breath environment.35
Nitric oxide (NO) NO level is elevated in asthma with inflammatory. Asthma102, 103 Cobalt tetraphenylpor phyrin (CoTPP)104 and phenylenediam ine derivatives.105 Polystyrene (PSt), ethylcellulose (EC), polycyclohexyl methacrylate (PCHMA),104 and microporous cellulose membrane.105 The hydrophobic polymer matrix significantly improved the humidity resistance.104 A Nafion tubing was integrated to avoid the humidity interference.105
Hydrogen sulfide (H2S) An endogenous gaseous signaling molecule and potential therapeutic agent.106 Bad breath107 Lead(II) acetate,10 silver nanoparticles,108 and copper(II) complex.107 Polyacrylonitrile nanofibers,10 nylon membrane,108 and Prozorb substrate.107 Sensor can detect sub-ppm H2S gas in high relative humidity (~90% RH).10 The sensitivity of the sensor is retained in 50–96% RH, but decreased at low humidity level, e.g. 20% RH.108
Ammonia (NH3) Associated with blood urea nitrogen Renal failure109111 pH indicators109,110 Hydrogel film (with the combination of polyvinyl alcohol, titanium oxide nanoparticles, and hydroquinone)109 The hydrogel film with the combination of other chemicals provides a versatile matrix to minimize the environmental interference.109
VOCs Volatile organic compounds (VOCs) related to metabolic changes within cancer cells. Lung cancer8,91, 92 Metalloporphyr ins, pH indicators, and dyes with large permanent dipoles.8, 91, 92 Poly(vinylidene fluoride) membrane92 Sensor is stable against humidity because of the high hydrophobicity of polyvinylidene fluoride.92