Abstract
Background
Myopia is a condition in which the focusing power (refraction) of the eye is greater than that required for clear distance vision. There are two main types of surgical correction for moderate to high myopia; excimer laser and phakic intraocular lenses (IOLs). Excimer laser refractive surgery for myopia works by removing corneal stroma to lessen the refractive power of the cornea and to bring the image of a viewed object into focus onto the retina rather than in front of it. Phakic IOLs for the treatment of myopia work by diverging light rays so that the image of a viewed object is brought into focus onto the retina rather than in front of the retina. They can be placed either in the anterior chamber of the eye in front of the iris or in the posterior chamber of the eye between the iris and the natural lens.
Objectives
To compare excimer laser refractive surgery and phakic IOLs for the correction of moderate to high myopia by evaluating postoperative uncorrected visual acuity, refractive outcome, potential loss of best spectacle corrected visual acuity (BSCVA) and the incidence of adverse outcomes.
Search methods
We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 1), Ovid MEDLINE, Ovid MEDLINE In‐Process and Other Non‐Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to February 2014), EMBASE (January 1980 to February 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled‐trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 11 February 2014.
Selection criteria
We included randomised controlled trials (RCTs) comparing excimer laser refractive surgery and phakic IOLs for the correction of myopia greater than 6.0 diopters (D) spherical equivalent.
Data collection and analysis
Two authors independently assessed trial quality and extracted data. We performed data analysis. We summarised data for outcomes using odds ratios. We used a fixed‐effect model as only three trials were included in the review.
Main results
This review included three RCTs with a total of 228 eyes. The range of myopia of included patients was ‐6.0 D to ‐20.0 D of myopia with up to 4.0 D of myopic astigmatism. The percentage of eyes with uncorrected visual acuity (UCVA) of 20/20 or better at 12 months postoperative was not significantly different between the two groups. Phakic IOL surgery was safer than excimer laser surgical correction for moderate to high myopia as it results in significantly less loss of best spectacle corrected visual acuity (BSCVA) at 12 months postoperatively. However there is a low risk of developing early cataract with phakic IOLs. Phakic IOL surgery appears to result in better contrast sensitivity than excimer laser correction for moderate to high myopia. Phakic IOL surgery also scored more highly on patient satisfaction/preference questionnaires.
Authors' conclusions
The results of this review suggest that, at one year post surgery, phakic IOLs are safer than excimer laser surgical correction for moderate to high myopia in the range of ‐6.0 to ‐20.0 D and phakic IOLs are preferred by patients. While phakic IOLs might be accepted clinical practice for higher levels of myopia (greater than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism), it may be worth considering phakic IOL treatment over excimer laser correction for more moderate levels of myopia (less than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism). Further RCTs adequately powered for subgroup analysis are necessary to further elucidate the ideal range of myopia for phakic IOLs. This data should be considered alongside comparative data addressing long‐term safety as it emerges.
Plain language summary
Excimer laser versus phakic intraocular lenses for the correction of moderate to high short‐sightedness
Background Myopia is a condition in which the focusing power (refraction) of the eye is greater than that required for clear vision of distant objects. Myopia is a common cause of visual disability throughout the world. The World Health Organization (WHO) has grouped myopia and uncorrected refractive error among the leading causes of blindness and vision impairment in the world. The overall power of the lens that would be needed to correct the myopia is expressed in diopters (D) of a sphere. Most people have some degree of astigmatism where the eye is better at focusing light in one meridian than it is at another. It is possible to combine the effect of any astigmatism with the overall focusing power of the eye as a spherical equivalent in diopters. There are two main types of surgical correction for moderate to high myopia; excimer laser and phakic intraocular lenses (IOLs). Excimer laser refractive surgery for myopia works by removing corneal stroma to lessen the refractive power of the cornea and to bring the image of a viewed object into focus onto the retina rather than in front of it. Phakic IOLs for the treatment of myopia work by diverging light rays so that the image of a viewed object is brought into focus onto the retina rather than in front of it. They can be placed either in the anterior chamber of the eye in front of the iris or in the posterior chamber of the eye between the iris and the natural lens.
Study characteristics This review included three randomised controlled trials with a total of 228 eyes. The range of myopia of included patients was ‐6.0 D to ‐20.0 D with up to 4.0 D of myopic astigmatism.
Key results The results of this review showed that the chance of the uncorrected visual acuity being 20/20 or better was not different between the two groups. Phakic IOL surgery was safer than excimer laser surgical correction for moderate to high myopia as it results in significantly less loss of best spectacle corrected visual acuity (BSCVA) at 12 months postoperatively. Phakic IOL surgery appears to result in better contrast sensitivity than excimer laser correction for moderate to high myopia. Phakic IOL surgery also scored more highly on patient satisfaction/preference questionnaires. Neither technique resulted in any complication that caused a loss of final BSCVA.
Quality of the evidence Only studies that fulfilled the proper requirements were selected for inclusion in the analysis. The limitations of the studies that we included were the relatively short follow up period of one year as well as the fact that many of the interventions studied have now been superseded by more technologically advanced alternatives. In the present day the technology available for both excimer laser and phakic IOL surgical correction of high myopia is better than during the period of the included studies.
Conclusion This review showed that phakic IOLs for the treatment of high myopia were safer and preferred by patients when compared with excimer laser. Studies looking at more up to date technology with longer follow to determine long term safety issues are needed.
Background
Description of the condition
Myopia is also known as short‐sightedness or near‐sightedness. It is a condition in which the focusing power (refraction) of the eye is greater than that required for clear distance vision. The ocular determinants of refraction are the focusing power of the cornea and crystalline lens and the length of the eye (Fredrick 2002). In myopia, light from distant objects is focused in front of the retina instead of directly onto it. This occurs because the corneal curvature is too strong, the lens power is too strong, the eye is too long or a combination of these factors. As a result objects in the distance appear blurred. Near objects appear less blurred or may be seen clearly, depending on the degree of myopia. When the myopia is corrected (see 'Description of the intervention' below) the aim is normally to focus light directly onto the retina. When light is focused directly onto the retina the eye is described as being emmetropic.
Most cases of myopia present in children of school age and young adults. The presenting complaint is difficulty reading objects at a distance. Diagnosis is based on the results of refraction (spectacle testing). The overall power of the lens that would be needed to correct the myopia is expressed in diopters (D) of a sphere. Most people have some degree of astigmatism where the eye is better at focusing light at one angle than it is at another. It is possible to combine the effect of any astigmatism with the overall focusing power of the eye as a spherical equivalent in diopters.
Myopia is a common cause of visual disability throughout the world. The World Health Organization (WHO) has grouped myopia and uncorrected refractive error among the leading causes of blindness and vision impairment in the world (Fredrick 2002;Pararajasegaram 1999). The prevalence of myopia varies with age, country, ethnic group, level of education and occupation. The prevalence of myopia in Western populations is estimated to be approximately 25% (Kempen 2004; Sorsby 1960; Sperduto 1983). In some Asian populations myopia prevalence is as high as 70% to 90% (Chow 1990; Wong 2000). According to epidemiological evidence the prevalence of myopia is increasing, especially in Asian populations (Rajan 1995; Tay 1992).
There is substantial evidence that both genetic and environmental factors play a role in its aetiology (Fredrick 2002; Mutti 1996). People with myopia can be broadly classified into two groups:1) those with low to moderate myopia (less than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism) and 2) those with high myopia (greater than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism) (FDA 1997).
Description of the intervention
The most commonly used methods for correcting myopia are spectacle correction and contact lens wear. These conservative optical methods provide temporary correction of myopia. Surgical procedures have been developed in an attempt to permanently correct myopia. There are a variety of reasons why patients with myopia request refractive surgery as an alternative to contact lenses or spectacles. These reasons include:
Contact lenses may be inconvenient, not tolerated or may be deemed unsafe.
Spectacles may be associated with unacceptable aberrations, glare and/or reduction of visual field.
Spectacles may be cosmetically unacceptable or inconvenient.
The goal of refractive surgery is to safely and predictably create a stable and desired refractive state without causing new optical problems. In order to correct myopia the refractive power of the eye must be decreased, either by increasing the anterior radius of curvature of the cornea (flattening the curvature of the anterior corneal surface) or by insertion of a synthetic intraocular lens (IOL) of appropriate power. There are several surgical techniques available for the treatment of myopia. These techniques are, broadly speaking, divided into two groups; those involving surgery on the cornea (corneal refractive surgery) and those involving surgery on the lens (lenticular refractive surgery). These techniques are outlined below.
Corneal refractive surgery
Corneal ablation by excimer laser
Laser assisted stromal in‐situ keratomileusis (LASIK).
Epithelial laser assisted in‐situ keratomileusis (Epi‐LASIK).
Photorefractive keratectomy (PRK).
Laser assisted subepithelial keratomileusis (LASEK).
Corneal addition procedures
Intracorneal ring segments (e.g. INTACS); most commonly used to treat keratoconus.
Epikeratophakia (removal of epithelium and placement of a donor lenticule of Bowman’s layer and anterior stroma).
Keratophakia (intrastromal placement of a donor lenticule of corneal stroma after raising a microkeratome flap or by creating a stromal pocket by lamellar dissection).
Intracorneal lens (placement of hydrogel lens inside the corneal stroma).
Compression sutures (steepen the cornea to reduce astigmatism).
With the exception of intracorneal ring segments, the other corneal addition procedures are not currently in widespread use.
Corneal relaxation procedures
Radial keratotomy (peripheral deep stromal radial incisions) has been generally abandoned in favour of laser surgery.
Arcuate keratotomy (paired peripheral stromal incisions parallel to the limbus); most often used to treat astigmatism after corneal graft surgery.
Limbal relaxing incisions (deep limbal incisions of varying arc) are used during cataract surgery to reduce pre‐existing corneal astigmatism.
Corneal thermocoagulation
Thermokeratoplasty (heating the peripheral cornea to shrink collagen and steepen the central corneal curvature) can be used to treat hyperopia or presbyopia.
Lenticular refractive surgery
Refractive lens exchange
This is extraction of the natural lens and insertion of a posterior chamber IOL i.e. ‘cataract surgery’ in the absence of a visually significant cataract.
Phakic IOL
This is the insertion of an additional synthetic lens in front of the natural lens, placed either behind the iris in the ciliary sulcus or clipped to the iris in the anterior chamber.
Multifocal lens
These lenses have concentric ring segments that have two different focal lengths for distance and near vision.
Toric lens
These lenses have a cylindrical power to address astigmatism.
How the intervention might work
Excimer laser refractive surgery for myopia works by removing corneal stroma to lessen the refractive power of the cornea and to bring the image of a viewed object into focus onto the retina rather than in front of it.
Phakic IOLs for the treatment of myopia work by diverging light rays so that the image of a viewed object is brought into focus onto the retina rather than in front of the retina. They can be placed either in the anterior chamber of the eye in front of the iris or in the posterior chamber of the eye behind the iris and in front of the natural lens in the ciliary sulcus.
Why it is important to do this review
In recent years excimer laser refractive surgery has been the preferred refractive surgical procedure for most patients seeking spectacle independence (Chang 2006; Duffey 2004). Excimer laser refractive surgery has the benefit of rapid visual recovery, excellent visual outcomes and relatively painless postoperative recovery. For patients with moderate to high degrees of myopia, excimer laser refractive surgery may be less predictable and less safe. Iatrogenic keratectasia, optical aberrations, severe night glare, flap‐related complications and significant loss of spectacle corrected visual acuity have been reported (el Danasoury 1998; Knorz 1998; Seiler 1998; Stulting 1999).
Phakic IOLs, approved by the US Food and Drug Administration (FDA) in September 2004, represent a new alternative surgical treatment for moderate to high myopia. Phakic IOLs have the benefit of being a reversible procedure. Their insertion requires intraocular surgery which carries the risk of endophthalmitis, surgically induced astigmatism, corneal endothelium loss, chronic uveitis, pupillary block glaucoma, pigment dispersion syndrome and cataracts. In addition, the lens power calculation and surgical implantation of phakic IOLs require special techniques and the long term outcomes of several types of phakic IOLs are unknown (Espandar 2008).
Which of these two methods for correction of moderate to high myopia is more accurate, more stable and more safe than the other has not been assessed to date by a systematic review. This review will evaluate data from randomised controlled trials (RCTs) in order to address this question.
Objectives
To compare excimer laser refractive surgery and phakic IOLs for the correction of moderate to high myopia by evaluating postoperative uncorrected visual acuity, refractive outcome, potential loss of best spectacle corrected visual acuity (BSCVA) and the incidence of adverse outcomes.
Methods
Criteria for considering studies for this review
Types of studies
We included all RCTs that met the inclusion criteria.
Types of participants
We included trials in which the participants were males and females over 21 years of age and under 60 years of age undergoing excimer laser refractive surgery or phakic IOL insertion for myopia greater than 6.0 D of spherical equivalent. We excluded participants under 21 years of age due to the frequent change in refractive error still occurring in this age group. We excluded participants over 60 years of age on the basis that some degree of cataract is observed in the majority of these patients and corneal refractive procedures will not correct aberrations or reduced visual acuity caused by cataract. We also excluded participants with myopia that is lower than 6.0 D as there is currently little evidence to support the use of phakic IOLs in such patients. We excluded participants undergoing LASIK for correction of refractive errors other than primary myopia, for example post corneal graft, and participants with any other simultaneous ocular disease.
Types of interventions
We included studies in which excimer laser refractive surgery was compared with phakic IOL insertion for correction of moderate to high myopia.
Types of outcome measures
Primary outcomes
Percentage of eyes with uncorrected visual acuity (UCVA) of 20/20 or better at 12 months post‐treatment.
Secondary outcomes
Percentage of eyes with UCVA of 20/20 or better at six months post‐treatment.
Percentage of eyes within ±0.50 D of target refraction at six months post‐treatment.
Percentage of eyes within ±0.50 D of target refraction at 12 months post‐treatment.
Percentage of eyes within ±1.00 D of target refraction at six months post‐treatment.
Percentage of eyes within ±1.00 D of target refraction at 12 months post‐treatment.
Percentage of eyes that lost 2 or more lines of BSCVA at six months post‐treatment.
Percentage of eyes that lost 2 or more lines of BSCVA at 12 months post‐treatment.
Percentage of eyes that lost 1 or more lines of BSCVA at six month post‐treatment.
Percentage of eyes that lost 1 or more lines of BSCVA at 12 months post‐treatment.
Percentage of eyes with UCVA of 20/40 or better at six months post‐treatment.
Percentage of eyes with UCVA of 20/40 or better at 12 months post‐treatment.
The secondary outcome measures listed above have been modified slightly from those initially set out in the protocol. We have added the percentage of eyes within ±1.0 D of target refraction at six and 12 months post‐treatment as this provides further important information on the accuracy of the procedure. We have also added the percentage of eyes that lost 1 or more lines of BSCVA at six and 12 months post‐treatment in order to provide more information on potential safety measures for the two procedures. The 12 month time point for both of these additions is reported by all three RCTs and therefore allows us to adequately address the diversity of outcomes reported in the individual trials.
Adverse effects
We examined the incidence of severe complications, that is, those leading to significant permanent visual loss (loss of 2 or more lines from pre‐treatment best corrected visual acuity) within 24 months of treatment, arising directly as a result of undergoing treatment. We examined the incidence of flap related complications (whether or not they resulted in significant visual loss) in patients undergoing LASIK. We examined the incidence of corneal endothelial cell loss, pupillary block glaucoma, pigment dispersion syndrome, uveitis, large visually significant iridectomies, need for IOL exchange and endophthalmitis in the phakic IOL group. We assessed minor complications such as dry eye symptoms, glare or haloes under quality of life measures using suitable patient satisfaction questionnaires, and we also assessed changes in contrast sensitivity. For paired eye studies it was not possible to look at such quality of life issues and we needed to restrict the quality of life analysis to studies where the separate interventions were performed on separate individuals.
Search methods for identification of studies
Electronic searches
We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 1), Ovid MEDLINE, Ovid MEDLINE In‐Process and Other Non‐Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to February 2014), EMBASE (January 1980 to February 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled‐trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 11 February 2014.
See: Appendices for details of search strategies for CENTRAL (Appendix 1), MEDLINE (Appendix 2), EMBASE (Appendix 3), LILACS (Appendix 4), mRCT (Appendix 5), ClinicalTrials.gov (Appendix 6) and the ICTRP (Appendix 7).
Searching other resources
We searched the reference lists of the studies included in the review for information about further trials. We contacted experts in the field for further information. We used the Science Citation Index to search for papers that cite any studies included in this review. We did not handsearch journals or conference proceedings specifically for this review.
Data collection and analysis
Selection of studies
Both authors independently assessed the titles and abstracts resulting from the searches and screened the full copies of all relevant studies against the inclusion criteria. We dealt with potential discrepancies and unclear studies by contacting the authors for clarification and additional information.
Data extraction and management
Both authors extracted data independently using a standard data collection form. We compared the results and resolved any disagreements by discussion. One author entered data into RevMan (RevMan 2012) and then both authors independently checked the data entered. We extracted the following details from the studies: methods, participants, interventions, outcomes and notes.
Assessment of risk of bias in included studies
Both review authors assessed studies that met the inclusion criteria for methodological quality. We considered the following domains of quality: random sequence generation (to determine whether the sequence allocation was adequately generated), allocation concealment, masking (blinding) of outcome assessors (to determine whether knowledge of the allocated intervention was adequately prevented during the study), incomplete outcome data, selective outcome reporting and other sources of bias. As the two treatments concerned are inherently different, masking of participants and providers was not possible and was not assessed. We graded each domain of trial quality as: low risk of bias, high risk of bias or unclear. We resolved any disagreements between the review authors by discussion. We contacted the trial authors for clarification on any domain assessed as unclear. We did not perform sensitivity analyses as there were too few RCTs included to make this worthwhile. Furthermore we included all trials in our analysis as none were graded as high risk of bias on 'allocation concealment and concealment approach'.
Measures of treatment effect
All outcome measures stated are dichotomous, with the exception of "postoperative patient satisfaction scores" which are ordinal. For dichotomous outcomes we calculated an odds ratio. Ordinal outcomes included a large enough number of categories to assume similar characteristics to continuous outcomes and therefore we calculated a standardized mean difference.
Unit of analysis issues
The preferred unit of analysis were outcomes for eyes rather than individuals, since some individuals might have had unilateral treatment or different treatments in each eye. Paired eye studies, where one eye had been randomised to one intervention and the second eye had by default gone on to receive the other intervention, were included as carry‐over and period effects were not thought likely to be a problem. Similarly we included paired eye cluster studies where both eyes were randomised to the same intervention. We included the effect estimate for these paired studies in the meta‐analysis using the generic inverse‐variance method.
Dealing with missing data
Where we were unable to extract all the information we were interested in from published reports, both with regard to the details of the study and its numerical results, we requested the missing data from the original investigators.
Assessment of heterogeneity
We endeavoured to identify differences between the studies which were likely to introduce heterogeneity. As some degree of heterogeneity always exists due to the clinical and methodological diversity of the studies, we employed the results of the Chi2 test as well as I2 statistic to quantify inconsistencies across studies.
Assessment of reporting biases
In order to investigate whether our review was subject to reporting biases, we examined the relevant funnel plots for signs of asymmetry in RevMan (RevMan 2012).
Data synthesis
We performed the data analysis according to Chapter 9 of the Cochrane Handbook for Systematic Reviews of Interventions (Deeks 2011) and summarised data for outcomes using odds ratios. We used a fixed‐effect model for our analyses as only three trials were included.
Subgroup analysis and investigation of heterogeneity
As per our protocol, we did not perform subgroup analyses.
Sensitivity analysis
We did not perform a sensitivity analyses in order to evaluate how robust the results of the review were relative to decisions and assumptions made in the process of conducting the review. There were too few RCTs included to make this worthwhile. Furthermore we included all trials in our analysis as none were graded as high risk of bias on 'allocation concealment and concealment approach'.
Results
Description of studies
Results of the search
The electronic searches identified 221 reports of trials. Of these, seven were retrieved for further assessment of which three studies were included and four studies were excluded.
An update search was done in November 2011. After deduplication the search identified a total of 53 references. The Trials Search Co‐ordinator scanned the search results and removed any references which were not relevant to the scope of the review. We reviewed the remaining three references but they did not meet the inclusion criteria for the review.
An update search run in February 2014 identified a further 90 references (Figure 1). The Trials Search Co‐ordinator removed 27 duplicates and screened the remaining 63 references, of which 46 were not relevant to the scope of the review. We reviewed the remaining 17 reference and obtained one full‐text report (Albarran‐Diego 2012) for potential inclusion in the review. However, the trial did not meet the inclusion criteria and we excluded the study.
1.
Results from searching for studies for inclusion in the review.
Included studies
The following is a summary of the characteristics of the three RCTs that met the review inclusion criteria (el Danasoury 2002; Malecaze 2002; Schallhorn 2007). Further details can be found in the 'Characteristics of included studies' table.
Types of participants
The three RCTs included a total of 228 eyes of 132 consecutive patients. The age range of all included patients was 21 to 52 years. All included patients had a stable refraction for at least 12 months prior to inclusion. The range of myopia of included patients was 6.0 D to 20.0 D with up to 4.0 D of myopic astigmatism. One study included patients with between 9.0 and 19.5 D of myopia and refractive astigmatism less than 3.0 D (el Danasoury 2002). One study included patients with bilateral myopia between 8.0 and 12.0 D with an astigmatism less than 1.5 D (Malecaze 2002). One study included patients with myopia between ‐6.0 to ‐20.0 D and astigmatism in the range of 1.0 to 4.0 D (Schallhorn 2007). Exclusion criteria included: previous refractive surgery, keratoconus or keratoconus suspected by videokeratography, active ocular disease, dry eyes, systemic disease likely to affect corneal wound healing (such as connective tissue disease) and inability to achieve the follow‐up schedule given to the patients before surgery.
Types of interventions
Two of the studies compared LASIK with the Artisan phakic IOL (el Danasoury 2002; Malecaze 2002). The Artisan phakic IOL is an iris claw‐fixated anterior chamber lens. One study compared PRK and mitomycin C (MMC) augmentation with the Visian Toric Implantable Collamer Lens (Schallhorn 2007). The Visian Toric Implantable Collamer Lens (STAAR Surgical) has a toric anterior surface and is designed to vault anteriorly to the crystalline lens in the ciliary sulcus. The excimer laser platforms and nomograms used varied between studies but not within individual studies. For LASIK procedures the microkeratomes used for flap creation varied between studies but not within studies. For all surgery the refractive aim was emmetropia.
Types of outcome measures
The primary and secondary outcomes, as well as adverse outcomes, are set out above. All three trials reported data for some of the primary and secondary outcome measures. No trial reported data for every outcome measure. The studies involving the Artisan phakic IOL provided data on corneal endothelial cell counts. All studies provided data on patient satisfaction questionnaires.
Excluded studies
One trial was excluded because the minimum follow up was less than one year (Soliman 1999). A further two studies were excluded because the eyes were not randomised to treatments (Morara 1999; Sanders 2003). In Morara 1999 there was no specific mention of randomisation. We attempted contact with the various authors involved to confirm that there was no randomisation to treatments but no response was forthcoming. We, therefore, assumed that randomisation was not performed. We contacted the authors of Kamiya 2008 and they confirmed that the two groups were not randomised and therefore this study was not included.
In the latest update of this review (2014), we excluded one study (Albarran‐Diego 2012) because there were several limitations with this study. Firstly the fact that two eyes of each participant were randomised to the same intervention is a source of bias. Secondly the fact that the upper limit cut off of myopia was only ‐9.0 in this study excludes the results from a meaningful analysis. The really relevant participants are those with more than ‐9.0 of myopia which were included in all of the original studies that were part of our meta‐analysis. Finally the laser technology used (the VisX S2) is essentially out of date technology.
See the 'Characteristics of excluded studies' table for further details.
Risk of bias in included studies
2.
Risk of bias graph: review authors' judgements about each risk of bias item presented as percentages across all included studies.
3.
Risk of bias summary: review authors' judgements about each risk of bias item for each included study.
One of the studies randomised each eye involved to the individual treatments being compared (el Danasoury 2002) such that some participants had LASIK in one eye and phakic IOL in the other and some had bilateral phakic IOL or bilateral LASIK. Another study (Schallhorn 2007) did not specify whether eyes or participants were randomised to the individual treatments. The authors were contacted regarding this and kindly responded stating that where participants underwent bilateral treatment, both eyes were randomised to the same treatment. The third study (Malecaze 2002) used a paired eye comparison where one eye was randomised to an individual treatment and the other eye received the other treatment by default. We have no reason to believe that surgery on one eye could influence the outcome of the surgery on the other eye or vice versa and therefore we did not consider carry‐over and period effects to be a problem.
Allocation
The method of sequence generation for one of the studies was not specified (Schallhorn 2007). A random number table was used for the other two studies (el Danasoury 2002, Malecaze 2002). All three studies were graded as unclear on allocation concealment.
Blinding
As the two treatments concerned are inherently different, masking of participants and providers was not possible and was therefore deemed to have not been done in all studies. One study, Malecaze 2002, masked the assessors and we therefore graded it as low risk of bias for this parameter. We graded the other two studies (el Danasoury 2002; Schallhorn 2007) as unclear on masking of assessors.
Incomplete outcome data
This was assessed as low risk of bias in all studies. Losses to follow up were reported and were equal in both groups of each study.
Selective reporting
All of the studies reported on all of the pre‐specified primary and secondary outcomes. However, none of the studies provided information on whether the methods used in the statistical analysis were pre‐specified or not and therefore we graded all studies as unclear for selective reporting.
Other potential sources of bias
We did not identify any other potential threats to validity for the included studies.
Effects of interventions
1. Visual acuity
a. Percentage of eyes with uncorrected visual acuity (UCVA) of 20/20 or better at 12 months post‐treatment (primary outcome) (see Analysis 1.1)
1.1. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 1 Uncorrected visual acuity of 20/20 or better at 12 months post‐treatment.
Data were available for analysis for a total of 166 eyes in two trials (el Danasoury 2002; Schallhorn 2007). Analysis of the data showed no difference between the two groups (odds ratio (OR) 1.33, 95% confidence interval (CI) 0.08 to 22.55, P = 0.84).
b. Percentage of eyes with UCVA of 20/20 or better at six months post‐treatment (secondary outcome) (see Analysis 1.2)
1.2. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 2 UCVA of 20/20 or better at 6 months post‐treatment.
Data were available for analysis for a total of 157 eyes in two trials (el Danasoury 2002; Schallhorn 2007). Analysis of the data showed no difference between the two groups (OR 0.99, 95% CI 0.25 to 3.91, P = 0.99).
c. Percentage of eyes with UCVA of 20/40 or better at six months post‐treatment (secondary outcome) (see Analysis 1.3)
1.3. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 3 UCVA of 20/40 or better at 6 months post‐treatment.
Data were available for analysis for a total of 125 eyes in two trials (el Danasoury 2002; Malecaze 2002). Analysis of the data showed no difference between the two groups (OR 0.71, 95% CI 0.36 to 1.39, P = 0.32).
d. Percentage of eyes with UCVA of 20/40 or better at twelve months post‐treatment (secondary outcome) (see Analysis 1.4)
1.4. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 4 UCVA of 20/40 or better at 12 months post‐treatment.
Data were available for analysis for a total of 134 eyes in two trials (el Danasoury 2002; Malecaze 2002). Analysis of the data showed no difference between the two groups (OR 0.66, 95% CI 0.36 to 1.22, P = 0.18).
2. Refraction (accuracy)
a. Percentage of eyes within ±0.50 D of target refraction at six months post‐treatment (secondary outcome) (see Analysis 1.5)
1.5. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 5 Percentage of eyes within ±0.50 D of target refraction at six months post‐treatment.
One study (Schallhorn 2007) reported data for this outcome. In this study there was significantly greater accuracy in the phakic IOL group (P = 0.02). We included subtotals only in the meta‐analysis.
b. Percentage of eyes within ±0.50 D of target refraction at 12 months post‐treatment (secondary outcome) (see Analysis 1.6)
1.6. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 6 Percentage of eyes within ±0.50 D of target refraction at 12 months post‐treatment.
Data were available for analysis for a total of 216 eyes in three trials (el Danasoury 2002; Malecaze 2002; Schallhorn 2007). Analysis of data showed no difference between the two groups (OR 0.72, 95% CI 0.40 to 1.29, P = 0.27).
c. Percentage of eyes within ±1.00 D of target refraction at six months post‐treatment (secondary outcome) (see Analysis 1.7)
1.7. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 7 Percentage of eyes within ±1.00 D of target refraction at six months post‐treatment.
One study (Schallhorn 2007) reported data for this outcome. In this study there was significantly greater accuracy in the phakic IOL group (P = 0.03). We included subtotals only in the meta‐analysis.
d. Percentage of eyes within ±1.00 D of target refraction at 12 months post‐treatment (secondary outcome) (see Analysis 1.8)
1.8. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 8 Percentage of eyes within ±1.00 D of target refraction at 12 months post‐treatment.
Data were available for analysis for a total of 216 eyes in three trials (el Danasoury 2002; Malecaze 2002; Schallhorn 2007). Analysis of data showed no difference between the two groups (OR 1.01, 95% CI 0.42 to 2.45, P = 0.98).
3. Safety measures
a. Percentage of eyes that lost 2 or more lines of BSCVA at six months post‐treatment (secondary outcome)
Only one study (Schallhorn 2007) reported data for this outcome. In this study there were no patients in either group who lost 2 or more lines of BSCVA and it was therefore not possible to generate an odds ratio for this outcome.
b. Percentage of eyes that lost 2 or more lines of BSCVA at 12 months post‐treatment (secondary outcome) (see Analysis 1.9)
1.9. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 9 Percentage of eyes that lost 2 or more lines of BSCVA at 12 months post‐treatment.
Data were available for analysis for a total of 216 eyes in three trials (el Danasoury 2002; Malecaze 2002; Schallhorn 2007). Analysis of data showed that the phakic IOL group were less likely to lose 2 or more lines of BSCVA at 12 months post‐treatment than the excimer laser group and this effect was statistically significant (OR 0.35, 95% CI 0.19 to 0.66, P = 0.001).
c. Percentage of eyes that lost 1 or more lines of BSCVA at six months post‐treatment (secondary outcome) (see Analysis 1.10)
1.10. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 10 Percentage of eyes that lost 1 or more lines of BSCVA at 6 months post‐treatment.
One study reported data for this outcome (Schallhorn 2007). In this study there was no difference between the two groups (P = 0.12). We included subtotals only in the meta‐analysis.
d. Percentage of eyes that lost one or more lines of BSCVA at 12 months post‐treatment (secondary outcome) (see Analysis 1.11)
1.11. Analysis.
Comparison 1 Excimer laser versus phakic IOL, Outcome 11 Percentage of eyes that lost 1 or more lines of BSCVA at 12 months post‐treatment.
Data were available for analysis for a total of 216 eyes in three trials (el Danasoury 2002; Malecaze 2002; Schallhorn 2007). Analysis of data showed that the phakic IOL group were less likely to lose 1 or more lines of BSCVA at 12 months post‐treatment than the excimer laser group and this effect was statistically significant (OR 0.41, 95% CI 0.33 to 0.51, P = 0.00001).
Safety Index
Although Malecaze 2002 did not report data directly on loss of BSCVA at six months it does give a measure of safety as a safety index which is expressed as the ratio of the mean postoperative BSCVA over the mean preoperative BSCVA. In this study at three, six and 12 months postoperatively they show that the safety index was significantly higher in the phakic IOL treated eyes than in the excimer laser treated eyes at all periods (three, six and 12 months postoperative) except at one month.
4. Adverse effects
Due to inconsistency between studies it was not possible to combine data for adverse effects and hence a descriptive account of the findings is provided.
a. Incidence of flap/interface/decentered ablation/haze related complications in laser treated eyes
One study (el Danasoury 2002) reported a single case of diffuse lamellar keratitis which completely resolved with topical steroid treatment. There were no other cases reported of flap, interface complications or haze and there were no studies that reported decentered ablations. These results are summarised in Table 1.
1. Flap/interface/decentered ablation related complications in excimer laser treated eyes.
Study | Complication rate | Flap/interface complication | Management | Outcome |
el Danasoury 2002 | 1 interface complication in 45 LASIK treatments. No other flap/decentered ablation complications | Diffuse lamellar keratitis 3 days after uneventful LASIK | Topical steroid therapy | Inflammation completely resolved within one week |
Malecaze 2002 | 0 flap/interface/decentered ablation complications in 25 LASIK treatments | N/A | N/A | N/A |
Schallhorn 2007 | Flap/interface complications N/A as all treatments PRK. No decentered ablations or haze reported in 45 laser treatments | N/A | N/A | N/A |
LASIK: laser assisted stromal in‐situ keratomileusis PRK: photorefractive keratectomy
b. Endothelial cell loss
Two studies examined endothelial cell loss (el Danasoury 2002; Malecaze 2002). Both of these studies found no significant difference between endothelial cell loss in the two groups. These results are summarised in Table 2.
2. Endothelial cell loss.
Study | Follow‐up | Findings |
el Danasoury 2002 | One year | The mean endothelial cell loss 0.7% ± 1.1% (range ‐3.1% to 1.7 %) at 1 year in the Artisan group and mean 0.3% ± 0.9% (range ‐1.9% to 1.8%) at 1 year in the LASIK group. There was no statistically significant difference between endothelial cell loss in the 2 groups |
Malecaze 2002 | One year | The differences between mean endothelial cell loss in LASIK treated eyes and Artisan‐treated eyes was not statistically different at either 3 months (P = 0.73) or 1 year (P = 0.60) postoperatively |
Schallhorn 2007 | Endothelial cell loss was not reported. | N/A |
LASIK: laser assisted stromal in‐situ keratomileusis
c. Incidence of cataract in the phakic IOL group
One study (Schallhorn 2007) reported, at two years postoperatively, the presence of an anterior subcapsular cataract in one (2.3%) phakic IOL patient who was lost to follow up until two years postoperatively. The patient's BCVA had reduced to 20/50‐1. The patient underwent successful removal of the phakic IOL and cataract with implantation of a posterior chamber pseudophakic IOL. One month after surgery the BSCVA was 20/20. In the same study there was one further patient who was noted to have a visually insignificant anterior lens opacity throughout the follow‐up period. The other two studies, which used anterior chamber phakic IOLs, did not report any cases of lens opacification or cataract.
d. Incidence of glaucoma/uveitis in the phakic IOL group
One study (Malecaze 2002) measured intraocular pressure (IOP) preoperatively and at one, three, six and 12 months postoperatively. There was no significant change in IOP in the phakic IOL group. In the LASIK group there was a significant reduction in apparent IOP (P < 0.001). The same study measured flare and did not find any significant difference between preoperative and postoperative patients in both groups. One other study (el Danasoury 2002) reported two (4.4%) cases of transient ocular hypertension that responded to topical therapy and resolved upon discontinuation of the topical steroid. There were no cases of glaucoma or uveitis reported in any study.
e. Need for IOL exchange in the phakic IOL group
Two studies (el Danasoury 2002; Schallhorn 2007) reported the need for IOL exchange in the phakic IOL group. The rate of incidence ranged from 2.2% to 2.3%. In both studies a BSCVA of 20/20 was restored following IOL exchange. These results are summarised in Table 3.
3. Need for IOL exchange in the phakic IOL group.
Study | IOL exchange rate | Indication for IOL exchange | Management | Outcome |
el Danasoury 2002 | 1 eye (2.2%) | Severe night glare in a patient with a preoperative pupil at dim illumination of 5mm who received a 5 mm Artisan lens | Lens was removed and exchanged for a 6 mm Artisan lens | Night glare completely resolved. UCVA was 20/40 correcting to 20/20 |
Malecaze 2002 | 0 cases reported of IOL exchange | N/A | N/A | N/A |
Schallhorn 2007 | 1 eye (2.3%) | Anterior subcapsular cataract resulting in BCVA 20/50‐1 | Phakic IOL and cataract were removed and replaced with pseudophakic IOL | BSCVA of 20/20 |
BCVA: best corrected visual acuity BSCVA: best spectacle corrected visual acuity IOL: intraocular lens UCVA: uncorrected visual acuity
f. Changes in contrast sensitivity
All three studies reported contrast sensitivity outcomes. In Malecaze 2002 there is an apparent slight benefit to Artisan over LASIK but this is not statistically significant. Similarly, in el Danasoury 2002 there is an apparent advantage to Artisan IOL over LASIK but the trialists do not report whether this is statistically significant or not. Schallhorn 2007 shows the phakic IOL group to be significantly better than the excimer laser treated group for both scotopic and mesopic contrast sensitivity at most time points postoperatively. These results are summarised in Table 4.
4. Changes in contrast sensitivity.
Study | Method | Findings |
el Danasoury 2002 | Measured using the Vision Contrast Test System (VCTS‐6000, Vistech consultants, Inc. Dayton, OH) performed under normal room lighting | One year after surgery the contrast sensitivity curve of each eye was compared to its baseline curve. Two Artisan eyes (4.7%) and six LASIK eyes (14.6%) lost 2 or more lines, three Artisan eyes (7.0%) and nine LASIK eyes (22.0%) lost 1 line, four Artisan eyes (9.3%) and no LASIK eyes gained 2 or more lines, and seven Artisan eyes (16.3%) and five LASIK eyes (12.2%) gained 1 line. The contrast sensitivity did not change in 27 Artisan eyes (62.8%) and 21 LASIK eyes (51.2%). There was no comment on whether this difference was statistically significant or not |
Malecaze 2002 | Not described | Pre‐operative contrast sensitivity measurements to one year postoperative measurements were slightly reduced in the LASIK group and slightly improved in the phakic IOL group. However this difference was not statistically significant at all 4 spatial frequencies (P = 0.66, 0.70, 0.06 and 0.29 for 3, 6, 12 and 18 cycles per degree cyc/deg respectively) |
Schallhorn 2007 | Photopic contrast sensitivity was conducted with a back‐illuminated chart (5% ETDRS Chart, 9x14, Model 2186; Precision Vision, LaSalle, ILL) with room lights off. Mesopic testing was conducted with a 25% ETDRS chart (Precision Vision) behind two neutral density filters and room lights off | 5% photopic level: The mean BSCVA (logMAR) was significantly better in the phakic IOL group than the PRK laser group at all time points postoperatively (P = 0.002 at one week and P = <0.001 at all other time points). Loss of 2 or more lines of BSCVA was significantly higher in the PRK group at all time points except six months. Improvement in BSCVA by 2 or more lines and 1 or more lines was significantly better in the phakic IOL group from 1 to 12 months postoperatively 25% mesopic level: The mean BSCVA (logMAR) was significantly better in the phakic IOL group than the PRK laser group at all time points postoperatively (P = 0.048 at one week and P = <0.001 at all other time points). Improvement in BSCVA (2 or more lines) was significantly better in the phakic IOL group at all time points from 1 to 12 months. Losses of 1 or more lines of BSCVA was significantly higher in the PRK group at all time points after one week. Improvement of one or more lines of BSCVA was better in the phakic IOL series at 1, 3 and 12 months |
BSCVA: best spectacle corrected visual acuity ETDRS: Early treatment diabetic retinopathy study IOL: intraocular lens LASIK: laser assisted stromal in‐situ keratomileusis PRK: photorefractive keratectomy
g. Subjective evaluation and quality of vision
All three studies report subjective evaluation and quality of vision outcomes. Of the patients who received Artisan in one eye and LASIK in the other, Artisan was the preferred procedure. Schallhorn 2007 showed that the phakic IOL group scored significantly higher for a number of satisfaction parameters. All three studies show that glare and halos are more of a problem with excimer laser than with phakic IOLs. The results are summarised in Table 5.
5. Subjective evaluation and quality of vision.
Study | Methods | FIndings |
el Danasoury 2002 | Patient satisfaction and preference questionnaire at 12 months postoperatively. This was only given to the 18 patients that had Artisan in one eye and LASIK in the other eye | There was no significant difference in the satisfaction levels between the two groups. 11 patients (61.1%) experienced more night glare or halos with their LASIK eye, 3 patients (16.7%) had more night glare with their Artisan eye, 1 patient (5.6%) reported equal glare in both eyes and 3 patients (16.7%) said that they had no glare with either eye (P = 0.001) Patient preference for Artisan was significantly higher (P = 0.0001) mainly because of better reported quality of vision |
Malecaze 2002 | Patient satisfaction questionnaire at 12 months postoperatively | There was a slightly significantly increased frequency of halos following LASIK (P = 0.05) and non‐significantly increased frequency of halos following Artisan (P = 0.19). Both groups showed a significantly increased frequency of glare (P = 0.02 for LASIK and P = 0.01 for Artisan) but there was no statistically significant difference between the two groups (P = 0.30 for halos and P = 0.20 for glare). The satisfaction levels were not statistically different (P = 0.40) between the two groups. Concerning preference for one of the two techniques: 16% of patients preferred LASIK, 44% preferred Artisan and 40% had no preference |
Schallhorn 2007 | Psychometric questionnaire was given preoperatively and 3, 6 and 12 months postoperatively. The questionnaire assessed subjective quality of vision (glare, halos, night vision, need for artificial tears) and satisfaction after the surgery | The PRK group showed significantly more need for artificial tears (P = 0.002) and more visual fluctuation (0.001) at the 3 and 6 month postoperative time periods. The PRK group had more glare symptoms at night (P = 0.033) and more trouble with oncoming car headlights at night (P = 0.014). All other questions at 3 and 6 months showed no difference between the two groups. The 12‐month questionnaire showed similar subjective visual results between the two groups with the exception of greater use of artificial tears in the PRK group (P = 0.008) and greater glare when watching television or computer monitors (P = 0.043) |
LASIK: laser assisted stromal in‐situ keratomileusis PRK: photorefractive keratectomy
Discussion
Summary of main results
The percentage of eyes with UCVA of 20/20 or better at 12 months postoperatively was not significantly different between the two groups.
Phakic IOL surgery is safer than excimer laser surgical correction for moderate to high myopia. It results in significantly less final loss of BSCVA.
There is a low risk of developing early cataract with phakic IOLs.
Phakic IOL surgery appears to result in better contrast sensitivity than excimer laser correction for moderate to high myopia. Phakic IOL surgery also scores more highly on patient satisfaction/preference questionnaires.
Overall completeness and applicability of evidence
Three RCTs met the review inclusion criteria (el Danasoury 2002; Malecaze 2002; Schallhorn 2007). All three trials reported data for some of the primary and secondary outcome measures. No trial reported data for every outcome measure and hence not all of the trials could be included in each of the outcome analyses. The studies involving the Artisan phakic IOL provided data on corneal endothelial cell counts. All studies provided data on patient satisfaction questionnaires. Incomplete outcome data were adequately addressed in all studies. Losses to follow‐up were reported and were equal in both groups of each study. All of the studies reported on all of the pre‐specified primary and secondary outcomes.
It should be noted that all systematic reviews are subject to the potential problem of multiplicity due to problems such as selective reporting of results or analyses by individual trials. For instance, when the results of a study are presented, it is not always possible to know how many tests or analyses were done. It is likely that in some studies interesting findings were selected for presentation or publication in relation to statistical significance, and other 'uninteresting' findings omitted, leading to misleading results and spurious conclusions (Deeks 2011).
There is some heterogeneity of the results between the studies for some of the outcomes. There are a variety of potential explanations as to why this might be. All three studies included patients with slightly different degrees of myopia and myopic astigmatism. None of the studies break down the treatment effect into subgroups with different levels of baseline refractive error and therefore it is not possible to take these potential differences into account when combining the studies into the analysis. Furthermore the excimer laser procedures are able to address myopic astigmatic error with a toric ablation profile but the Artisan lens used in el Danasoury 2002 and Malecaze 2002 could not address myopic astigmatism. It is possible that in these studies the potential benefit from phakic IOLs has been underestimated given that toric phakic IOLs are now readily available. The toric IOL used in Schallhorn 2007 was able to address myopic astigmatism and therefore may represent a more fair comparison of the two techniques. Another potential reason for heterogeneity is the issue of enhancement LASIK procedures that were administered in el Danasoury 2002, four to six months after the primary procedure, to patients in either group who had a residual refractive error of more than 1.0 D at the three month examination. It is possible that this could again result in an underestimation of the difference between the two groups. Another potential source of heterogeneity between the studies is due to Schallhorn 2007 being more contemporaneous than the other two studies, and it is possible that the excimer laser treatment nomograms as well as the IOL calculation formulae were more advanced in this study.
Studies looking at risk factors for progression to ectasia after excimer laser refractive surgery (Randleman 2008) recommend not performing LASIK on myopia greater then 14 D. However excimer laser surface ablation such as PRK may be safer on higher levels of myopia but this has not been properly established in clinical trials. All of the studies include a relatively high range of myopia and myopic astigmatism. None of the studies attempted to perform a subgroup analysis on smaller ranges of myopia in order to specifically determine exactly what population of moderate to highly myopic patients would most benefit from phakic IOLs.
Quality of the evidence
A major issue with this review is trial quality according to established modern criteria. In the presence of such concern, emphasis on the evidence of effectiveness must be cautious, as it is possible that systematic bias in the studies has led to overestimation of effect. The methodological quality of the trials that were included is in some cases unclear. For example, there is uncertainty about the allocation concealment in all three studies.
Potential biases in the review process
The mixture of study designs (unilateral versus bilateral treatment) posed a problem with data synthesis. In order to include data from all study types it was assumed that the response of any eye to one treatment was in no way related to or predictable from the response of the fellow eye. Paired eye studies, where one eye had been randomised to one intervention and the second eye had by default gone on to receive the other intervention, were therefore included. Similarly we included paired eye cluster studies where both eyes were randomised to the same intervention. We included the effect estimate for these paired studies in the meta‐analysis using the generic inverse variance method. If we had analyzed the paired and unpaired data separately, there would have only been one trial with paired data, one trial with unpaired data and one trial with some paired and some unpaired data. Given that all trials did not report on all the outcomes and at all time points it would not otherwise have been possible to combine the studies into an analysis in a meaningful way.
The secondary outcome measures listed above were modified slightly from those initially set out in the protocol by the addition of new outcomes. Care must be taken in not placing too much weight on these additional secondary outcomes so as not to result in selective outcome reporting. Furthermore the review process is subject to the potential problem of multiplicity because of multiple outcomes in the review. The primary outcome for this study was the percentage of eyes with UCVA of 20/20 or better at 12 months post‐treatment. The review revealed no significant difference in this outcome. This review shows that phakic IOLs are more accurate and safe than excimer laser. However the accuracy conclusion relates to only a single trial outcome (Schallhorn 2007). The safety outcomes are representative of lines of BSCVA lost. Adverse events were examined separately. One potential limitation of meta‐analysis of RCTs is insufficient evidence to comment on serious rare adverse events. The reason for this which is certainly applicable in the trials analyzed in this review is the relatively short follow up and small numbers in each trial. It is important to acknowledge that accuracy and safety were secondary outcomes and some of the secondary outcomes were added post protocol submission.
Agreements and disagreements with other studies or reviews
The largest study that has been conducted comparing phakic IOL and LASIK (Sanders 2003) was excluded as the participants were not randomised to individual treatments. This study compared the results of 559 eyes that underwent LASIK and 210 eyes that underwent posterior chamber phakic IOL insertion (also known as the implantable contact lens, STAAR Surgical, Monrovia, CA). These series were concurrently operated on with 8.0 D to 10.0 D of preoperative myopia and were examined at one day, one week, one month, six months and one year postoperatively. Results from this study showed that every index of BSCVA, UCVA and predictability of refraction studied favoured the phakic IOL over LASIK. This study did not include subjective evaluation and quality of vision questionnaires. During the one year course of the study there was one phakic IOL‐related secondary surgery; a lens repositioning at two weeks postoperatively. There were no reported clinically significant lens opacities. 4.3% of the phakic IOL group required an additional LASIK procedure. 23% of the LASIK treated eyes required an enhancement with further LASIK treatment. Diffuse lamellar keratitis occurred in 3% of eyes, and 2.1% of eyes required a flap lift to smooth out flap related striae.
The results of this review also seem to favour phakic IOL over excimer laser surgical correction for moderate to high myopia (the range in this review was ‐6.0 to ‐20.0 D) particularly for the following parameters of accuracy and safety; refraction ± 0.50 D at six months and ± 1.00 D at six months, the percentage of eyes that lost 1 or more lines of BSCVA at 12 months post‐treatment and the percentage of eyes that lost 2 or more lines of BSCVA at 12 months post‐treatment. The subjective evaluation as well as quality of vision questionnaires in the individual studies favour phakic IOL over excimer laser surgical correction for moderate to high myopia.
Authors' conclusions
Implications for practice.
The results of this review suggest that phakic IOLs are more accurate and safe than excimer laser surgical correction for moderate to high myopia in the range of ‐6.0 to ‐20.0 D. While this is accepted clinical practice for higher levels of myopia (greater than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism), it may be worth considering phakic IOL treatment over excimer laser correction for more moderate levels of myopia (less than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism). It is possible that the reason that phakic IOL surgery is not in more common use for moderate myopia may reflect the greater level of surgical complexity and skill required to perform it safely.
Patients undergoing posterior chamber phakic IOLs should be counselled about the risk of cataract and the potential need for further surgical intervention. Furthermore there may be more long term risks unique to patients with phakic IOLs, such as continued endothelial cell loss and cataract formation, that are not apparent in only one year of follow‐up.
The poor quality of the presented evidence means that any interpretation must be cautious.
Implications for research.
Further trials comparing phakic IOLs (ideally toric phakic IOLs) and excimer laser surgical correction exclusively for moderate myopia may be warranted. The same primary and secondary outcome measures together with specified time points as those used in this review would be appropriate. It would also be helpful to have more long term outcome data to carefully monitor late adverse events. Furthermore any future trials should utilise a more standardized vision related quality of life scoring system so that subjective results can be included in a meta‐analysis. In order to facilitate comparison between future trials in refractive surgery a standardized framework of outcome measures and follow‐up intervals should be developed and used. Future trials should follow CONSORT guidelines to ensure that reporting of RCTs is complete. A separate search strategy specifically looking at reports of serious rare adverse effects may be more helpful than meta‐analysis for providing this information.
What's new
Date | Event | Description |
---|---|---|
17 June 2014 | New citation required but conclusions have not changed | Issue 6, 2014: One RCT excluded, plain language summary updated |
17 June 2014 | New search has been performed | Issue 6, 2014: Searches updated |
History
Protocol first published: Issue 2, 2009 Review first published: Issue 5, 2010
Date | Event | Description |
---|---|---|
29 November 2011 | New citation required but conclusions have not changed | Issue 1 2012: Electronic searches were updated but no new studies were identified for inclusion in this update. |
29 November 2011 | New search has been performed | Issue 1 2012: Risk of bias assessment has been changed to reflect updated Cochrane methodology. |
Acknowledgements
The Cochrane Eyes and Vision Group created and executed the electronic search strategies. We would like to thank Anupa Shah, Richard Wormald, Alex Shortt, Catey Bunce and Vincenzo Maurino for their help and comments on this review.
Richard Wormald (Co‐ordinating Editor for CEVG) and Bruce Allan (Co‐Author) acknowledge financial support for research sessions from the Department of Health through the award made by the National Institute for Health Research to Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology for a Specialist Biomedical Research Centre for Ophthalmology. The views expressed in this publication are those of the authors and not necessarily those of the Department of Health.
Appendices
Appendix 1. CENTRAL search strategy
#1 MeSH descriptor Myopia #2 myop* #3 sight* AND (short or near*) #4 (#1 OR #2 OR #3) #5 MeSH descriptor Corneal Surgery, Laser #6 keratectom* #7 keratomileusis #8 LAS?K #9 PRK #10 laser* near/3 refractive near/3 surg* #11 laser* near/3 epithel* near/3 surg* #12 excimer near/3 laser* #13 (#5 OR #6 OR #7 OR #8 OR #9 OR #10 OR #11 OR #12) #14 MeSH descriptor Lenses, Intraocular #15 MeSH descriptor Lens Implantation, Intraocular #16 lens* or IOL* #17 (#14 OR #15 OR #16) #18 (#4 AND #13 AND #17)
Appendix 2. MEDLINE (OvidSP) search strategy
1. randomized controlled trial.pt. 2. (randomized or randomised).ab,ti. 3. placebo.ab,ti. 4. dt.fs. 5. randomly.ab,ti. 6. trial.ab,ti. 7. groups.ab,ti. 8. or/1‐7 9. exp animals/ 10. exp humans/ 11. 9 not (9 and 10) 12. 8 not 11 13. exp myopia/ 14. myop$.tw. 15. ((short or near) adj3 sight$).tw. 16. or/13‐15 17. exp corneal surgery, laser/ 18. keratectom$.tw. 19. keratomileusis.tw. 20. LAS?K.tw. 21. PRK.tw. 22. (laser$ adj3 refractive adj3 surg$).tw. 23. (laser$ adj3 epithel$ adj3 surg$).tw. 24. (excimer adj3 laser$).tw. 25. or/17‐24 26. exp lenses intraocular/ 27. lens implantation intraocular/ 28. (lens$ or IOL$).tw. 29. or/26‐28 30. 16 and 25 and 29 31. 12 and 30
The search filter for trials at the beginning of the MEDLINE strategy is from the published paper by Glanville et al (Glanville 2006).
Appendix 3. EMBASE (OvidSP) search strategy
1. exp randomized controlled trial/ 2. exp randomization/ 3. exp double blind procedure/ 4. exp single blind procedure/ 5. random$.tw. 6. or/1‐5 7. (animal or animal experiment).sh. 8. human.sh. 9. 7 and 8 10. 7 not 9 11. 6 not 10 12. exp clinical trial/ 13. (clin$ adj3 trial$).tw. 14. ((singl$ or doubl$ or trebl$ or tripl$) adj3 (blind$ or mask$)).tw. 15. exp placebo/ 16. placebo$.tw. 17. random$.tw. 18. exp experimental design/ 19. exp crossover procedure/ 20. exp control group/ 21. exp latin square design/ 22. or/12‐21 23. 22 not 10 24. 23 not 11 25. exp comparative study/ 26. exp evaluation/ 27. exp prospective study/ 28. (control$ or prospectiv$ or volunteer$).tw. 29. or/25‐28 30. 29 not 10 31. 30 not (11 or 23) 32. 11 or 24 or 31 33. exp myopia/ 34. exp high myopia/ 35. myop$.tw. 36. ((short or near) adj3 sight$).tw. 37. or/33‐36 38. exp keratectomy/ 39. exp photorefractive keratectomy/ 40. exp keratomileusis/ 41. exp laser epithelial keratomileusis/ 42. keratectom$.tw. 43. keratomileusis.tw. 44. LAS?K.tw. 45. PRK.tw. 46. (laser$ adj3 refractive adj3 surg$).tw. 47. (laser$ adj3 epithel$ adj3 surg$).tw. 48. (excimer adj3 laser$).tw. 49. or/38‐48 50. exp lens implant/ 51. exp lens implantation/ 52. (lens$ or IOL$).tw. 53. or/50‐52 54. 37 and 49 and 53 55. 32 and 54
Appendix 4. LILACS search strategy
myop$ or short sight$ or near sight$ and kerat$ or laser$ or LASIK or LASEK or PRK or photorefract$ and lens$ or IOL$
Appendix 5. metaRegister of Controlled Trials search strategy
myopia and IOL and refractive surgery
Appendix 6. ClinicalTrials.gov search strategy
Myopia AND IOL AND Refractive Surgery
Appendix 7. ICTRP search strategy
Myopia AND LASIK OR LASEK OR PRK AND Phakic OR Lens OR IOL
Data and analyses
Comparison 1. Excimer laser versus phakic IOL.
Characteristics of studies
Characteristics of included studies [ordered by study ID]
el Danasoury 2002.
Methods | Single centre, single surgeon prospective randomised trial | |
Participants | Setting: Magrabi Eye and Ear Centre, Abu Dhabi, United Arab Emirates Numbers randomised: 90 eyes of 61 consecutive patients Age: range 21 to 47 years (mean, 33.7+/‐ 7.1 years) Gender: 37 (60.7%) were female Inclusion criteria: Age of at least 21 years, documented stable refraction for 1 year, spherical equivalent refraction between 9.0 and 19.5 D of myopia, refractive astigmatism less than 3.0 D, spectacle‐corrected visual acuity of 20/40 or better, corneal thickness permitting the surgeon to leave at least 250 µm deep to the ablation, pupil size less than 6 mm in dim illumination for eyes with myopia of 15.50 D or less, and 5 mm for eyes with myopia greater than 15.50 D, and realistic expectations concerning the outcome Exclusion criteria: Previous refractive surgery, keratoconus or keratoconus suspected by videokeratography, active ocular disease, dry eyes, systemic disease likely to affect corneal wound healing (e.g. connective tissue disease) and inability to achieve the follow‐up schedule given to the patients before surgery |
|
Interventions | Emetropia was the refractive aim in all eyes Artisan phakic intraocular lens implantation: Lens power was calculated based on the refraction at the corneal plane according to a customised clinical nomogram based on the manufacturer's instructions and the authors previous experience with Artisan lens implantation LASIK: Nidek EC‐5000 excimer laser with mean ablation zone diameter 5.6 +/‐ 0.3 mm (range, 5.0 to 6.0 mm); and transition zone 1 mm. A personal customised clinical nomogram was used for all LASIK procedures. A Carriazo‐Barraquer microkeratome with a manually advanced turbine motor head was used to create a 160 µm flap for all LASIK procedures |
|
Outcomes | All patients were examined, at 1 day, 1 week, and 1, 3, 6 and 12 months postoperatively. Slit lamp microscopy, manifest refraction, uncorrected and spectacle corrected visual acuity were performed at all visits from one month onwards. Contrast sensitivity, videokeratography, and specular microscopy were done at the 1, 6 and 12 month examinations One year after surgery, a patient satisfaction questionnaire was given to the 18 patients (29.5%) who had Artisan lens in one eye and LASIK in the other eye |
|
Notes | LASIK enhancement procedures were performed in both groups 4 to 6 months after the primary procedure if there was a residual refractive error of more than 1.0 D at the 3 month examination. One Artisan eye (2.3%) and seven LASIK eyes (16.3%) had enhancement procedures | |
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | A random number table was used to generate the sequence |
Allocation concealment (selection bias) | Unclear risk | Not specified |
Blinding (performance bias and detection bias) Participants | High risk | Not mentioned but presumably not done as both procedures are inherently different and participants would know which procedure they were undergoing |
Blinding (performance bias and detection bias) Providers | High risk | Not mentioned but presumably not done as both procedures are inherently different and assessors would know which procedure had been performed |
Incomplete outcome data (attrition bias) All outcomes | Low risk | Losses to follow‐up were reported although no explanation was given as to why participants were lost to follow‐up |
Selective reporting (reporting bias) | Low risk | There was no evidence of selective outcome reporting |
Other bias | Low risk | No other sources of bias were detected |
Malecaze 2002.
Methods | Two surgeon, two centre prospective, single masked randomised trial with paired eye control | |
Participants | Numbers randomised: 25 consecutive patients (50 eyes) Age: range 31 to 52 years (mean 38.4 +/‐ 7.6 years) Gender: 17 (68%) were female Inclusion criteria: Stable myopia for 2 years and unsatisfactory correction by glasses or contact lenses. They had bilateral myopia between ‐8.0 and ‐12.0 with an astigmatism < 1.5 D. The anterior chamber depth was ≥ 3.0 mm, the endothelial cell count was ≥ 2000 cells/mm2, the corneal thickness was ≥ 530 µm and the mean keratometry was 42.0 to 45.0 D Exclusion criteria: Patients under the age of 30 years, corneal disease including keratoconus suspect with videokeratography, glaucoma, uveitis or a history of retinal detachment |
|
Interventions | Emmetropia was the target refraction in all eyes LASIK procedure: Keracor Technolas 217 C (Bausch & Lomb Surgical, Claremont, CA) was used. The software used was version 2.67, subgroup 036, with an ablation zone diameter of 5 mm and a peripheral treatment zone from 6 to 8.5 mm. The Hansotome (Bausch & Lomb Surgical, Claremont, CA) microkeratome was used to create a 160 µm flap Artisan procedure: The Artisan phakic intraocular lens, a convex‐concave, iris claw‐fixated lens with a 6 mm optical zone diameter (Artisan lens; Ophtec B.V., Groningen, Netherlands) was used. Patient refractive error, anterior chamber depth and keratometric values (Van der Heijde formula) were used to calculate the dioptric power of the lens |
|
Outcomes | The primary outcome measure was the postoperative spherical equivalent refraction at 1 year. The secondary outcome measure was safety measured by the percentage of eyes losing 2 or more Snellen lines of spectacle corrected visual acuity and the safety index Patients were examined postoperatively at 1 day, 1, 3 , 6 and 12 months after surgery. After day 1 postoperative all examinations included uncorrected and spectacle‐corrected visual acuity, refraction, slit‐lamp microscopy, applanation tonometry and corneal topography. At 3 months and 1 year postoperative an endothelial evaluation using a specular microscope was performed as well as contrast sensitivity. At 1 year postoperative a subjective evaluation and quality of vision score was calculated |
|
Notes | The evaluators did not participate in the surgical process. Both evaluators worked independently from any objective testing, such as slit‐lamp examination and corneal topography, which could have unmasked the surgical procedure. For this purpose independent evaluators performed objective tests | |
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | A random number table was used to generate the sequence |
Allocation concealment (selection bias) | Unclear risk | Not specified |
Blinding (performance bias and detection bias) Participants | High risk | Not mentioned but presumably not done as both procedures are inherently different and participants would know which procedure they were undergoing on each eye |
Blinding (performance bias and detection bias) Providers | Low risk | The evaluators did not participate in the surgical process. Both evaluators worked independently from any objective testing, such as slit‐lamp examination and corneal topography, which could have unmasked the surgical procedure |
Incomplete outcome data (attrition bias) All outcomes | Low risk | Losses to follow‐up were reported although no explanation was given as to why participants were lost to follow‐up |
Selective reporting (reporting bias) | Low risk | There was no evidence of selective outcome reporting |
Other bias | Low risk | No other sources of bias were detected |
Schallhorn 2007.
Methods | Single centre, uncertain number of surgeons, prospective randomised trial | |
Participants | Number randomised: 88 eyes of 46 patients Age: PRK group 32.6 +/‐ 7 years, Toric Implantable Collamer Lens (TICL) group 30.8 +/‐ 6 years Gender: PRK group 37% female, TICL group 44% female Inclusion criteria: Phakic patients with moderate to high myopia (‐6.0 to ‐20.0 D sphere) measured at the spectacle plane and astigmatism in the range of 1.0 to 4.0 D cylinder with a best spectacle‐corrected visual acuity of 20/40 or better in the eye to be treated. Patients had to be between the ages of 21 and 45 years and have a stable refraction for the last 12 months as documented by previous clinical records Exclusion criteria: Patients with a history of previous intraocular surgery, diabetes, glaucoma, ocular hypertension, amblyopia and any other serious ophthalmic or non‐ophthalmic conditions that may have precluded study completion |
|
Interventions | PRK: This was performed using a conventional PRK technique partnered with the use of mitomycin C (MMC). The VISX Star S3 (VISX Inc, Santa Clara, Calif) excimer laser was used with specifications of a 6.5 mm optical zone (major axis) with an 8.0 mm treatment zone TICL: The Visian TICL (STAAR Surgical) was implanted in all 43 eyes in the series. The TICL is designed to be placed behind the iris and to vault anteriorly to the crystalline lens. All TICL patients received iridotomies using an Nd:YAG laser 2 weeks prior to surgery. The TICL was inserted through a horizontal temporal 3 mm corneal incision then injected into the eye and dialled into position |
|
Outcomes | Visual measurements were collected to include uncorrected and best spectacle corrected vision and contrast sensitivity. Study follow up was 1 day, 1 week, and 1, 3, 6 and 12 months postoperatively. Additionally a psychometric subjective quality of vision and satisfaction after surgery questionnaire was given at the preoperative, 3 to 6 month and 12 month time points | |
Notes | ||
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Unclear risk | Not specified |
Allocation concealment (selection bias) | Unclear risk | Not specified |
Blinding (performance bias and detection bias) Participants | High risk | Not mentioned but presumably not done as both procedures are inherently different and participants would know which procedure they were undergoing |
Blinding (performance bias and detection bias) Providers | High risk | Not mentioned but presumably not done as both procedures are inherently different and assessors would know which procedure had been performed |
Incomplete outcome data (attrition bias) All outcomes | Low risk | Losses to follow‐up were reported although no explanation was given as to why participants were lost to follow‐up |
Selective reporting (reporting bias) | Unclear risk | There was no clear evidence of selective outcome reporting, however it should be noted that the one patient in the phakic IOL group who developed a cataract attended his one month postoperative visit and was then lost to follow up until 2 years after the surgery |
Other bias | Low risk | No other sources of bias were detected |
D: diopter LASIK: laser assisted stromal in‐situ keratomileusis IOL: intraocular lens PRK: photorefractive keratectomy
Characteristics of excluded studies [ordered by study ID]
Study | Reason for exclusion |
---|---|
Albarran‐Diego 2012 | Randomised controlled trial but several limitations including source of bias and out of date technology used |
Kamiya 2008 | The two groups were not randomised to treatment |
Morara 1999 | No randomisation to treatments |
Sanders 2003 | No randomisation to treatments |
Soliman 1999 | Minimum follow up less than one year |
Differences between protocol and review
We have added the percentage of eyes within ±1.00 D of target refraction at six and at 12 months post‐treatment as this provides further important information on the accuracy of the procedure. We have also added the percentage of eyes that lost 1 or more lines of BSCVA at six and at 12 months post‐treatment in order to provide more information on potential safety measures for the two procedures. The 12 month time point for both of these additions is reported by all three RCTs and therefore allows us to adequately address the diversity of outcomes reported in the individual trials.
Contributions of authors
AB conceived the review question and co‐ordinated the review, designed other search strategies, undertook manual searches, organised retrieval of full‐text copies, provided additional data about papers and entered data in to RevMan. BA provided general advice on review. AB and BA screened search results, screened retrieved papers against inclusion criteria, appraised quality of papers, extracted data from papers, wrote to authors for additional information, obtained and screened data on unpublished studies, performed analysis of data, provided methodological, clinical, policy and consumer perspective, wrote drafts of the review and responded to peer review comments and comments from the editorial base.
Update of review Issue 1, 2011 and Issue 6, 2014 AB and Cochrane Eyes and Vision Group (CEVG) Trials Search Co‐ordinator (TSC) screened search results. AB, CEVG Managing Editor and TSC updated the review (minor edits).
Declarations of interest
None
New search for studies and content updated (no change to conclusions)
References
References to studies included in this review
el Danasoury 2002 {published data only}
- Danasoury MA, Maghraby A, Gamali TO. Comparison of iris‐fixed Artisan lens implantation with excimer laser in situ keratomileusis in correcting myopia between ‐9.00 and ‐19.50 diopters: a randomized study. Ophthalmology 2002;109(5):955‐64. [DOI] [PubMed] [Google Scholar]
Malecaze 2002 {published data only}
- Malecaze FJ, Hulin H, Bierer P, Fournie P, Grandjean H, Thalamas C, et al. A randomized paired eye comparison of two techniques for treating moderately high myopia: LASIK and artisan phakic lens. Ophthalmology 2002;109(9):1622‐30. [DOI] [PubMed] [Google Scholar]
Schallhorn 2007 {published data only}
- Schallhorn S, Tanzer D, Sanders DR, Sanders ML. Randomized prospective comparison of visian toric implantable collamer lens and conventional photorefractive keratectomy for moderate to high myopic astigmatism. Journal of Refractive Surgery 2007;23(9):853‐67. [DOI] [PubMed] [Google Scholar]
References to studies excluded from this review
Albarran‐Diego 2012 {published data only}
- Albarrán‐Diego C, Muñoz G, Ferrer‐Blasco T, García‐Lázaro S, Belda‐Salmerón L. Foldable iris‐fixated phakic intraocular lens vs femtosecond laser‐assisted LASIK for myopia between ‐6.00 and ‐9.00 diopters. Journal of Refractive Surgery 2012;28(6):380‐6. [DOI] [PubMed] [Google Scholar]
Kamiya 2008 {published data only}
- Kamiya K, Shimizu K, Igarashi A, Komatsu M. Comparison of Collamer toric contact lens implantation and wavefront‐guided laser in situ keratomileusis for high myopic astigmatism. Journal of Cataract and Refractive Surgery 2008;34(10):1687‐93. [DOI] [PubMed] [Google Scholar]
Morara 1999 {published data only}
- Morara M, Scorolli LG, Scorolli L, Meduri R, Ricci R. LASIK and ICL (posterior chamber phakic lenses) for the correction of extreme myopia: A comparative study. Annali Di Ottalmologia e Clinica Oculistica 1999;125(9‐10):293‐301. [Google Scholar]
Sanders 2003 {published data only}
- Sanders DR, Vukich JA. Comparison of implantable contact lens and laser assisted in situ keratomileusis for moderate to high myopia. Cornea 2003;22(4):324‐31. [DOI] [PubMed] [Google Scholar]
Soliman 1999 {published data only}
- Soliman H, Maghraby A. Phakic ICL versus LASIK in treating high myopia. American Academy of Ophthalmology 1999:245. [Google Scholar]
Additional references
Chang 2006
- Chang DH, Davis EA. Phakic intraocular lenses. Current Opinion in Ophthalmology 2006;17(1):99‐104. [DOI] [PubMed] [Google Scholar]
Chow 1990
- Chow YC, Dhillon B, Chew PT, Chew SJ. Refractive errors in Singapore medical students. Singapore Medical Journal 1990;31(5):472‐3. [PubMed] [Google Scholar]
Deeks 2011
- Deeks JJ, Higgins JPT, Altman DG (editors). Chapter 9: Analysing data and undertaking meta‐analyses. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 (updated March 2011). The Cochrane Collaboration, 2011. Available from www.cochrane‐handbook.org.
Duffey 2004
- Duffy RJ, Leaming D. Trends in refractive surgery in the United States. Journal of Cataract and Refractive Surgery 2004;30(8):1781‐5. [DOI] [PubMed] [Google Scholar]
el Danasoury 1998
- Danasoury MA. Prospective bilateral study of night glare after laser in situ keratomileusis with single zone and transition zone ablation. Journal of Refractive Surgery 1998;14(5):512‐6. [DOI] [PubMed] [Google Scholar]
Espandar 2008
- Espandar L, Meyer JJ, Moshirfar M. Phakic intraocular lenses. Current Opinion in Ophthalmology 2008;19(4):349‐56. [DOI] [PubMed] [Google Scholar]
FDA 1997
- FDA. Discussion points for expansion of the “Checklist of Information Usually Submitted in an Investigational Device Exemption (IDE) Application for Refractive Surgery Lasers” draft document. www.fda.gov/medicaldevices/deviceregulationandguidance/guidancedocuments/ucm080208.htm (accessed 18 November 2008).
Fredrick 2002
- Fredrick DR. Myopia. BMJ 2002;324(7347):1195‐9. [DOI] [PMC free article] [PubMed] [Google Scholar]
Glanville 2006
- Glanville JM, Lefebvre C, Miles JN, Camosso‐Stefinovic J. How to identify randomized controlled trials in MEDLINE: ten years on. Journal of the Medical Library Association 2006;94(2):130‐6. [PMC free article] [PubMed] [Google Scholar]
Kempen 2004
- Kempen JH, Mitchell P, Lee KE, Tielsch JM, Broman AT, Taylor HR, et al. The prevalence of refractive errors among adults in the United States, Western Europe, and Australia. Archives of Ophthalmology 2004;122(4):495‐505. [DOI] [PubMed] [Google Scholar]
Knorz 1998
- Knorz MC, Wiesinger B, Liermann A, Seiberth V, Liesenhoff H. Laser In situ keratomileusis for moderate and high myopia and myopic astigmatism. Ophthalmology 1998;105(5):932‐40. [DOI] [PubMed] [Google Scholar]
Mutti 1996
- Mutti DO, Zadnik K, Adams AJ. Myopia. The nature versus nurture debate goes on. Investigative Ophthalmology and Visual Science 1996;37(6):952‐7. [PubMed] [Google Scholar]
Pararajasegaram 1999
- Pararajasegaram R. Vision 2020‐the right to sight: from strategies to action. American Journal of Ophthalmology 1999;128(3):359‐60. [DOI] [PubMed] [Google Scholar]
Rajan 1995
- Rajan U, Tan FT, Chan TK. Increasing prevalence of myopia in Singapore school children. Proceedings of the Fifth International Conference on Myopia. New York: Myopia Research Foundation, 1995:41‐6.
Randleman 2008
- Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk assessment for ectasia after corneal refractive surgery. Ophthalmology 2008;115(1):37‐50. [DOI] [PubMed] [Google Scholar]
RevMan 2012 [Computer program]
- The Nordic Cochrane Centre, The Cochrane Collaboration. Review Manager (RevMan). Version 5.2. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2012.
Seiler 1998
- Seiler T, Koufala K, Richter G. Iatrogenic keratectasia after laser in situ keratomileusis. Journal of Refractive Surgery 1998;14(3):312‐7. [DOI] [PubMed] [Google Scholar]
Sorsby 1960
- Sorsby A, Sheridan M, Leary GA, Benjamin B. Vision, visual acuity and ocular refraction of young men. Findings in a sample of 1,033 subjects. British Medical Journal 1960;1857(5183):1394‐8. [DOI] [PMC free article] [PubMed] [Google Scholar]
Sperduto 1983
- Sperduto RD, Seigel D, Roberts J, Rowland M. Prevalence of myopia in the United States. Archives of Ophthalmology 1983;101(3):405‐7. [DOI] [PubMed] [Google Scholar]
Stulting 1999
- Stulting RD, Carr JD, Thompson KP, Waring GO 3rd, Wiley WM, Walker JG. Complications of laser in situ keratomileusis for the correction of myopia. Ophthalmology 1999;106(1):13‐20. [DOI] [PubMed] [Google Scholar]
Tay 1992
- Tay MT, Au Eong KG, Ng CY, Lim MK. Myopia and educational attainment in 421,116 young Singaporean males. Annals of the Academy of Medicine, Singapore 1992;21(6):785‐91. [PubMed] [Google Scholar]
Wong 2000
- Wong TY, Foster PJ, Hee J, Ng TP, Tielsch JM, Chew SJ, et al. Prevalence and risk factors for refractive errors in an adult Chinese population in Singapore. Investigative Ophthalmology and Visual Science 2000;41(9):2486‐94. [PubMed] [Google Scholar]
References to other published versions of this review
Barsam 2008
- Barsam A, Allan BDS. Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia. Cochrane Database of Systematic Reviews 2010, Issue 5. [DOI: 10.1002/14651858.CD007679.pub2] [DOI] [PubMed] [Google Scholar]
Barsam 2012
- Barsam A, Allan BDS. Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia. Cochrane Database of Systematic Reviews 2012, Issue 1. [DOI: 10.1002/14651858.CD007679.pub3] [DOI] [PubMed] [Google Scholar]