Table 1.

Summarized data of the included studies—patients rehabilitated with implant-supported prosthesis on zirconia implants

Variable
  Patients (n)/implants (n) 2083/4017
  Age (years), mean ± SD (min–max) 51.2 ± 14.7 (1890)
Sex, n (%)
  Men/women 851 (42.4) /1,157 (57.6)
  Not available 75
  Implants per patient (n), mean ± SD (min–max) 1.91 ± 1.51 (114)
Implant type, n (%)
  One-piece 3818 (95.0)
  Two-piece 199 (5.0)
Implant location, n (%)
  Jaw
  Maxilla 2264 (58.1)
  Mandible 1,632 (41.9)
  Not available 121
Region
  Anterior 850 (24.8)
  Posterior 2572 (75.2)
  Not available 595
  Healing time (months), mean ± SD (min–max) 2.66 ± 1.79 (011)
  Immediate loading, number implants (%) 980 (24.4)
  0.5–3 months, number implants (%) 2097 (52.2)
  4–6 months, number implants (%) 911 (22.7)
  > 6 months, number implants (%) 29 (0.7)
Prosthesis type, n (%)
  Single crown 1326 (85.0)
  FDP (2–5 units) 150 (9.6)
  Overdenture 84 (5.4)
  Not available 2457
Follow-up (months), mean ± SD (min–max)
  Implants 68.8 ± 52.5 (0.3180.0)
  Prostheses 66.8 ± 52.4 (1.0177.0)
Preparation of the implant coronal part, n (%)
  No 3253 (81.0)
  Yes 764 (19.0)
Implant failure (n), failure/total (%)
  Implant level 172/4017 (4.3)
  Patient level 141/2083 (6.8)
  One-piece implant 157/3,818 (4.1)
  Two-piece implant 15/199 (7.5)
  Commercially available 78/3,182 (2.5)
  Not commercially availablea 94/835 (11.3)
Preparation of the implant coronal part
  No 115/3,253 (3.5)
  Yes 57/764 (7.5)
  Time of failure (months), mean ± SD (min–max) 12.0 ± 16.1 (0.386.0)
  Early failuresb, number/total (%) 47/115 (40.9)
  Implant fracturec, number/total (%) 26 d/172 (15.1)
  One-piece implant 25/3,818 (0.7)
  Two-piece implant 1/199 (0.5)
  Implant coronal part not prepared 8/3,245 (0.2)
  Drill-prepared coronal part 18/746 (2.4)
  Lost implant replaced by a new onee, number/total (%) 36/54 (66.7)
Implant location e, n (%)
  Maxilla anterior 41 (26.8)
  Maxilla posterior 45 (29.4)
  Mandible anterior 26 (17.0)
  Mandible posterior 41 (26.8)
Implant system, n (%)
  CeraRoot Ca 249 (6.2)
  CeraRoot ICE f 2114 (52.6)
  CeraRoot UC a 249 (6.2)
  Nobel Biocare ZiUnitea 122 (3.0)
  Own manufactureda 121 (3.0)
  Southern Implantsa 77 (1.9)
  Straumann PURE Ceramicf 374 (9.3)
  VITA ceramic.implantf 71 (1.8)
  VOLZIRKON1a 22 (0.6)
  VOLZIRKON2a 22 (0.6)
  White-SKYf 72 (1.8)
  Z-Look3a 338 (8.4)
  ZERAMEX Ta 49 (1.2)
  Ziraldent FR1f 53 (1.3)
  Ziteriona 16 (0.4)
  ZV3a 68 (1.7)

FDP, fixed dental prosthesis

aImplants that were discontinued by the manufacturers, namely, no longer produced. Or implants that were manufactured only for the study

bFailure up to the abutment connection; 57 out of the 172 failed implants were submitted to the immediate loading protocol

cPercentage from the implant cases that failed

dEighteen out of the 26 implant fractures (69.2%) were observed in the study of Roehling et al. [51]

eFor the cases with available information

fImplants commercially available