Table 1.
Summary of patients
| Case | Age, y | Sex | Lesion | A2/P2, mm | Ring, mm | Loop |
CPB, min | AXC, min | Expected coaptation depth‡, mm | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| ∗ | mm† | ||||||||||
| 1 | 64 | F | P2 | 26.0/24.0 | PF | 30 | 2 × 2 | A19, P19 | 144 | 98 | 10.5 |
| 2 | 53 | M | P2 lateral | 28.1/24.7 | CG | 34 | 1 × 3 | A18 | 143 | 99 | 10.3 |
| 3 | 61 | F | P2 lateral | 25.9/22.5 | PF | 30 | 1 × 2 | A20 | 107 | 67 | 10.5 |
| 4 | 59 | M | P2 | 26.4/23.8 | PF | 32 | 2 × 2 | A24, P22 | 122 | 68 | 10.1 |
| 5§ | 75 | M | P2 medial | 26.7/19.8 | PF | 30 | 1 × 2 | P19 | 144 | 104 | 10.9 |
A2/P2, Leaflet height of A2/P2 segment; CPB, cardiopulmonary bypass time; AXC, aortic crossclamp time; F, female; PF, Physio Flex annuloplasty ring (Edwards Lifesciences); M, male; CG, CG Future annuloplasty band (Medtronic).
Data are shown as number of bundles × number of loops. 2 × 2 means that a total of 4 loops were used.
The length of loops fixed to the anterior papillary muscle is shown as A00, whereas that fixed to the posterior papillary muscle is shown as P00.
Expected coaptation depth = (“anterior leaflet height” + “functional posterior leaflet height after repair [15 mm]” – “anteroposterior diameter of the band [roughly 2/3 of the labeled size]”)/2.
Concomitant aortic valve replacement.