Abstract
Objective
To develop and clinically evaluate a customizable active upper extremity (UE) assistive system with integrated functional electrical stimulation (FES) that improves function and independence of individuals during activities of daily living (ADLs).
Design
Single-arm, prospective, open-label cohort feasibility trial.
Setting
An academic research institution.
Participants
Subjects were 5 adults with a medical history of stroke resulting in distal UE impairment (N=5). The subjects volunteered from recruitment materials that detailed information about the study.
Interventions
A novel, wearable, lightweight, low-profile, and patient-tailored UE assistive system. It comprises a splint component and FES unit that may each be controlled by electromyography (EMG) signals, inertial measurement units (IMUs), manual control source (joystick), and/or voice control.
Main Outcome Measure(s)
Several occupational therapy outcome measures were used, including the Canadian Occupational Performance Measure (COPM), Action Research Arm Test (ARAT), The Box and Blocks Test (BBT), the ABILHAND-Manual Ability Measure, and Patient Reported Outcomes Measurement Information System (PROMIS) UE Short Form.
Results
All participants learned to use our UE assistive system to perform ADLs and were able to use it independently at home. Most participants experienced a clinically meaningful improvement in both performance and satisfaction for the majority of their COPM goals while using the system. All participants experienced improvement in hand grip and release as shown by their baseline and post assessment scores for hand function (BBT, ARAT) and patient-reported outcomes (ABILHAND, PROMIS).
Conclusions
The clinical outcomes suggest that our UE assistive system improves functional performance in patients with UE impairment, allowing them to engage more actively in ADLs. Further innovation including elbow and shoulder components will allow users to have more degrees of freedom during tasks.
KEYWORDS: Activities of daily living (ADLs), Hemiplegia, Neurological rehabilitation, Occupational therapy, Rehabilitation, Stroke
Stroke, spinal cord injury, muscular dystrophy, and other neurologic conditions frequently cause debilitating UE motor impairments that last beyond rehabilitation discharge.1 In adults, there is an enormous burden of cerebrovascular disease; each year, more than 795,000 people in the United States have a stroke.2 Over 75% of them will have permanent UE impairment at the chronic stage and difficulties performing activities of daily living (ADLs), which diminish quality of life.3, 4, 5 Occupational therapy (OT) and physical therapy are mainstays of rehabilitation for persons with chronic neurologic impairments and incorporate a variety of therapeutic approaches, such as activity-based therapy, neuromuscular and functional electrical stimulation (FES), biofeedback, virtual reality, and robotics. Passive and powered UE assistive systems, including orthoses, are also incorporated into rehabilitation, and studies have shown that therapy while using a UE orthosis leads to improvement in the function of the affected limb while using the device.6, 7, 8
Although several UE orthoses have been developed, the only commercially available, powered arm orthosis is a myoelectric powered hand-elbow orthosis that implements a myoelectric approach in which up to 4 surface electromyographic (muscle activity) signals control 2 motors that move the brace components, allowing for flexion and extension of the fingers and elbow. This myoelectric strategy is adopted from prosthetics, as myoelectric control has been integrated into prosthetic limb designs for over 70 years.9,10 Multi-week regimens incorporating the myoelectric powered hand-elbow orthosis as a therapeutic adjunct to rehabilitative therapy have been shown to increase UE function, use, and recovery in individuals with moderate UE deficit due to stroke.11, 12, 13
We intentionally designed our UE assistive system to address concerns raised by a participant in our previous clinical trial where the myoelectric powered hand-elbow orthosis was used to actuate UE movement.14 Specifically, we designed our system to be customizable in form, function, and controls, lightweight, easy to don and doff, and convenient to integrate into ADLs. The system comprises a modular, hinged, splint component, and FES unit that may each be controlled by electromyography (EMG) signals, inertial measurement units (IMUs), manual control source (joystick), and/or voice control. These features offer several benefits. For one, EMG signals tend to be unreliable and inconsistent; in our experience, individuals with upper motor neuron injury exhibit within-and across-day spontaneous variations in muscle tone and EMG signals. Unlike many “off-the-shelf” UE orthoses, our system is customizable: its splint component is custom-shaped to accommodate the user's anatomy, and the types and locations of its control source(s) are selected by the user and therapist for optimal functionality and ease of use. The functionality of our UE assistive system described in this paper cannot be directly compared with the myoelectric powered hand-elbow orthosis, because it does not currently incorporate an elbow motor. However, our system is lighter in weight (<340 g placed on the user's arm vs >900 g for the myoelectric orthosis forearm piece).
Our study was designed to develop and clinically evaluate our customizable active UE assistive system with integrated FES that improves function and independence of individuals during ADLs. Our goal in developing the system is to meet individual's unique needs and promote the adoption of the technology in clinical settings, at home, and in the community. The National Library of Medicine defines a prosthesis as, “a device designed to replace a missing part of the body or to make a part of the body work better;” we assert that our system is designed to make the upper extremity (UE) work better.15 The Food and Drug Administration defines a limb orthosis as a device, “worn on the upper or lower extremities to support, to correct, or to prevent deformities or to align body structures for functional improvement,” and we assert that this definition does not adequately describe the dynamic and modular nature of our system.16 Our system may be considered an external, wearable motor neuroprosthetic, analogous to an implanted motor neuroprosthetic.17
Our study incorporates an iterative device design process that incorporates feedback from occupational therapists, engineers, physicians, industrial designers, and research participants to improve upon the system design incrementally. The feasibility trial has obtained ethics board approval and is currently active and recruiting. In this report, we discuss the development of our system and clinical findings from the first 5 participants who completed the study.
Methods
The study design is a single-arm, open-label feasibility trial. It was approved by the Thomas Jefferson University Institutional Review Board. Details of the clinical trial protocol are available on clinicaltrials.gov (NCT04798378). Participants aged 4 and older with UE weakness, with wrist flexion or extension less than 3 out of 5 on the Manual Muscle Testing Scale due to a neurologic disease or injury were recruited. Inclusion and Exclusion criteria are listed in table 1, and the demographics of participants are summarized in table 2. Seven participants were enrolled. After consent, standardized clinical outcome assessments (COAs) were administered to establish each participant's baseline functional abilities and to set goals for the trial. Participants underwent three-dimensional (3D) scans of their forearm and hand and received a customized NuroSleeve. They then engaged in 8 weeks of OT sessions and, upon demonstrating their ability to use the NuroSleeve independently, started incorporating it into their ADLs at home. After the 8-week period, the standardized COAs were repeated. This sequence of study activities is shown in figure 1.
Table 1.
Inclusion and exclusion criteria
| Inclusion Criteria |
|
| Exclusion Criteria |
|
Table 2.
Participant demographics
| Participant ID | NS1 | NS3 | NS4 | 7NS6 | NS7 |
|---|---|---|---|---|---|
| Age range at time of trial enrollment | 41 | 53 | 40 | 53 | 52 |
| Biological sex | Man | Man | Man | Woman | Man |
| Race/ethnicity | Caucasian, Hispanic | Caucasian, Non-Hispanic |
Caucasian, Non-Hispanic |
Caucasian, Non-Hispanic |
African American, Non-Hispanic |
| Body mass index | 31.01 kg/m2 | 25.5 kg/m2 | 27.31 kg/m2 | 27.98 kg/m2 | 43.64 kg/m2 |
| Pre-stroke hand dominance | Left-handed | Right-handed | Right-handed | Right-handed | Right-handed |
| Stroke history | Large right-sided spontaneous basal ganglia hemorrhage | Ischemic stroke in right middle cerebral artery territory due to dissection and occlusion of the right internal carotid artery | Left basal ganglia hemorrhagic stroke | Right parietal-temporal cortical and subcortical hemorrhagic stroke | Lacunar right basal ganglia stroke |
| Other medical history | Decompressive hemicraniectomy | Traumatic brain injury superimposed upon stroke: may have affected cognition, processing speed, coordination of motor control | Major depression | None | Decompressive hemicraniectomy |
| Number of years since stroke at time of enrollment | 7 | 4 | 3 | 20 | 2 |
| Active chemical denervation (with botulinum toxin injections) of paretic arm at time of enrollment and while enrolled | Yes | No | Yes | Yes | No |
| Employment status at time of enrollment | On disability | On disability | On disability | Full-time employed office worker & cashier, driving | Full-time employed, police dispatcher (had been patrol until stroke made it unsafe to handle firearm) |
| Exam findings at time of enrollment | Left spastic hemiparesis, left inferior quadrantanopsia, hyperreflexia | Hypomimia, left upper extremity weakness, left leg brace | Right hemiparesis | Left hemiparesis | Left hemiparesis |
| NuroSleeve Orthosis Version | Jaeco | Jaeco | 3D-printed | 3D-printed | 3D-printed |
| FES feature used | No | No | Yes | Yes | Yes |
Fig 1.
Sequence of study activities in the NuroSleeve clinical trial.
The NuroSleeve
The NuroSleeve is an active UE assistive system composed of a custom, motorized 3D-printed splint, an external FES unit,a a main control unit, a clinical software suite for configuration, and a rechargeable battery. Its current design facilitates opening and closing of the hand via a linear actuator motor. Both the motor and FES component can be controlled by 1 or more sensors. The control options include (1) signals from surface EMG sensorsb that could be placed at a muscle selected by the research therapist (eg, biceps, triceps, brachioradialis, and wrist extensor muscles); (2) signals from IMU sensorsc placed at the shoulder, leg, or other location convenient for the user; (3) manual control from a small joystickd; and/or (4) voice recognitione (V3, ELECHOUSE, Shen Zhen, China). Each study participant worked with the occupational therapists to identify the most suitable control mode for their abilities and preferences. These control options were enabled via the NuroSleeve's main control unit and the clinical software suite, shown in figure 2.
Fig 2.
The NuroSleeve consists of the main control unit (center) which accepts different input control signals (left) to control 1 or more end effectors (right). Implementations are customized for each patient by the occupational therapist using the clinical configuration software.
The NuroSleeve incorporates optional FES. The microcontroller is agnostic as to whether a given control signal (eg, IMU positioned on the ipsilateral shoulder) is used to trigger the motor or the electrical stimulator: this decision is made by the therapist and user. The FES electrodes can be placed wherever they are deemed most helpful and may assist in actions that are combined simultaneously with the motorized hand open-close function (eg, stimulating the brachioradialis to add supination to hand grasp) or assist more indirectly (eg, stimulating muscles of the shoulder girdle for proximal stabilization or shoulder elevation). This functionality may be compared to the commercially available Bioness H200, a forearm orthosis that incorporates FES to the hand muscles. While the H200 may be used independently, it is marketed as a rehabilitation modality rather than as an assistive device.18
Occupational therapy
Study participants engaged in individualized 45-minute OT sessions 3 times per week over an 8-week period. OT sessions were tailored to participants based on their baseline evaluation and goals (as defined in the Canadian Occupational Performance Measure (COPM), subsequently described). While improving performance in the selected COPM activities was the primary goal of the intervention, the study incorporated principles of motor learning and motor control and task-specific activity-based therapy19, 20, 21 into each session, with and without the use of the NuroSleeve. The study therapists trained each participant on how to use the NuroSleeve to achieve their COPM goals. Once comfortable with the device and deemed ready to do so, the participant used the NuroSleeve unsupervised at home. The Spinal Cord Injury Physical Therapy and Occupational Therapy Basic Data Set was used to record intervention details.22
Clinical outcomes
The following outcome measures were implemented for all participants pre- and post- the 8-week period of therapy to assess the use of their affected UE. Participants completed assessments with and without the NuroSleeve worn and were given rest breaks of at least 30 minutes between the with- and without-device trials. The assessor was the same for pre- and post-assessments of each participant.
Canadian Occupational Performance Measure (COPM)
The COPM is an outcome measure designed to assess patient outcomes in areas of self-care, productivity, and leisure. The participant identifies activities that they would like to be able to do or perform better in, then rates their ability to perform each activity, and their satisfaction with their ability to perform it. It is rated on a scale of 1 (not able to do it at all/not satisfied at all) to 10 (able to do it extremely well/extremely satisfied).23 The test-retest reliability (intraclass correlation coefficient, or ICC) of COPM in adults with impairment in 1 or more ADLs is 0.67 for performance and the minimally clinically important difference (MCID) is 2 for performance.24, 25, 26
Action Research Arm Test (ARAT)
The ARAT is an observational test used to assess UE function. It consists of 19 task items grouped into categories of grasp, grip, pinch, and gross arm movements. Performance on each item is rated on a 4-point scale ranging from 0 (no movement possible) to 3 (movement performed normally).27,28 The maximum score is 57.29 The ARAT has an ICC of 0.97 in stroke and an MCID of 5.7 for chronic stroke.30,31
Box and Block Test (BBT)
The BBT is a test of manual dexterity. The participant transports as many (2.5 cm2) blocks as they can over a 15.2 cm tall partition in 1 minute. The score is the number of blocks transported.32 The measure has an excellent ICC of 0.96 in UE paresis and an MCID of 5.33
ABILHAND-Manual Ability Measure
The ABILHAND is an inventory of 23 activities for which the participant characterizes as either impossible, difficult, easy to complete, (or “not applicable” if they have not completed the activity within the past 3 months). It is scored using the Rasch model, which converts the raw ordinal score into a linear measure, where a higher score indicates less difficulty completing the tasks.34 The score is expressed in logits, a linear unit that expresses odds of success, with a range from -10 to 10. It has an ICC of 0.85 and an MCID of 0.26 to 0.35 logits in stroke.35,36
Patient Reported Outcomes Measurement Information System (PROMIS) UE Short Form
PROMIS, sponsored by the National Institutes of Health, is a system of validated, reliable measures that assess participant-reported outcomes. The PROMIS UE short form (SF) is in the physical function instrument in which the participant rates their ability to complete tasks on a 1-5 scale, where 1 is unable to do and 5 is without any difficulty. A maximum score is 35.37 The raw score is converted to a T score to standardize the score, with a mean of 50 and a standard deviation of 10. The measure has demonstrated validity across varied clinical populations for comparing symptoms and quality of life indicators.38 It has an MCID of 2.1.39
Results
The NuroSleeve was successfully developed through an iterative process (fig 1) that incorporated feedback from both participants and occupational therapists. The initial design incorporated a commercially available stainless-steel orthosis, the “Flex-Hinge Wrist Hand Orthosis”f as its splint component. The splint was manually fabricated by a technician at Jaeco to match the dimensions of the participant's impaired forearm and hand, using measurements and calculations made in a downloadable Orthometry Form.40 A linear actuatorg was fixed to the splint to drive opening and closing of the hand by moving the second and third fingers, shown in figure 3.
Fig 3.
(a) The NuroSleeve design that incorporated the Jaeco Flex Hinge Wrist Hand Orthosis, (b) Participant NS3 with the NuroSleeve donned, opening the affected hand by using a push button in the non-affected hand.
Feedback from study participants and clinicians led to an improvement in the splint component that permitted movement of all 4 fingers and provided a more precise fit to the user's forearm and hand. The next – and current – design of the NuroSleeve uses 3D printing to create a splint that accommodates the user's anatomy. The process involves taking a 3D scan of the participant's impaired hand (including the forearm, thumb, and 4 fingers), from which a computer-aided design model is created and printed using carbon fiber-reinforced nylon. The resulting splint has 4 sections: forearm, cuff, thumb, and fingers, as shown in figure 4. A linear actuator motor is attached to the forearm section and permits movement of all fingers against a stable thumb. The 3D customized NuroSleeve splint component weighs between 175 g and 310 g, depending on the size of the user's hand.
Fig 4.
Participant NS7 wearing the 3D printed NuroSleeve design (a) in the hand open position, (b) in the closed position, (c) and triggering finger flexion by using an mounted joystick controller with the unaffected hand.
Study participants and clinicians found that using a mechanical switch or an IMU was more practical to use than EMG, because they reduced the amount of time required to calibrate and set up the NuroSleeve's operational parameters. The manual controller and IMUs allowed participants to use the NuroSleeve without needing to connect to a computer to re-adjust any settings. Consequently, the NuroSleeve system setup was quick (less than 2 minutes) and only needed adjustment when the participant and the therapist wanted to change the control strategy.
NuroSleeves were designed, customized, and fabricated for 5 participants. Participants completed 24 OT sessions over 8 weeks and began using the NuroSleeve at home between 2 and 6 (mean =3.4) weeks of OT. As of the time of this manuscript, 2 participants (NS2 and NS5) have not completed therapy sessions because their UE deficits related to limitations of mobility about the elbow and shoulder respectfully, requiring design of new components to support and mobilize those joints.
Figure 5 and supplemental table S1 show the results of the primary outcome measure, COPM. Participants NS1, NS4, and NS7 experienced a clinically meaningful improvement (≥2 points) in both performance and satisfaction for most of their COPM goals while using the NuroSleeve independently at home and in the community. Table 3 provides baseline and post assessment scores for hand function (BBT, ARAT) and patient-reported outcomes (ABILHAND, PROMIS). Some outcome measures were not collected, due to either patient fatigue or research coordinator error; these are marked as NT, indicating “not tested” in the table. All participants who completed BBT and ARAT experienced improved handgrip and release; for some, this improvement was seen when not wearing the NuroSleeve. Participants NS4 and NS7 had decreased PROMIS scores post-assessment; however, participants NS1, NS3, NS4, and NS6 exhibited a clinically meaningful improvement in more than 1 outcome score.
Fig 5.
Performance and satisfaction scores on the COPM. The COPM rates performance “Per” (1= not able to do at all, 10= able to do extremely well) and satisfaction “Sat” (1= not satisfied at all, 10= extremely satisfied) of patient identified goals. “Post” scores refer to those achieved at post assessment visit. Values with a circle (●) have clinically meaningful improvement.
Table 3.
Baseline and post assessment scores
| Baseline | Post Assessment |
Change Score |
||||
|---|---|---|---|---|---|---|
| Without NuroSleeve | With NuroSleeve | Without | With | |||
| NS1 | ARAT | 1 | 2 | 9 | +1 | +8 |
| BBT | 0 | 0 | 3 | 0 | +3 | |
| ABILHAND Logit (SE) |
-1.044 (0.378) | -0.24 (0.369) | 3.837 (0.702) | |||
| PROMIS SF V2.0 T-Metric (SD) |
28.8 (2.2) | 35.3 (2) | 36.5 (2) | |||
| NS3 | ARAT | 0 | 0 | 10 | 0 | +10 |
| BBT | 0 | 0 | 6 | 0 | +6 | |
| ABILHAND Logit (SE) |
-2.282 (0.464) | -1.814 (35) | 0.135 (0.359) | |||
| PROMIS SF V2.0 T-Metric (SD) |
22.2 (3) | 23 (2.8) | 31.5 (2.6) | |||
| NS4 | ARAT | 4 | 4 | 15 | 0 | +11 |
| BBT | 0 | 0 | 1 | 0 | +1 | |
| ABILHAND Logit (SE) |
-1.335 (0.39) | 0.301 (0.409) | 3.624 (0.906) | |||
| PROMIS SF V2.0 T-Metric (SD) |
39.1 (2.4) | 23 (2.8) | 33.7 (2) | |||
| NS6 | ARAT | 0 | 6 | 4 | +6 | +4 |
| BBT | 0 | NT | 1 | NT | +1 | |
| ABILHAND Logit (SE) |
NT | NT | NT | |||
| PROMIS SF V2.0 T-Metric (SD) |
16.2 (3) | 30.7 (2.2) | 30.3 (2.1) | |||
| NS7 | ARAT | 9 | 2 | 2 | -7 | -7 |
| BBT | 0 | 0 | 0 | 0 | 0 | |
| ABILHAND Logit (SE) |
NT | -1.267 (0.556) | -0.178 (0.572) | |||
| PROMIS SF V2.0 T-Metric (SD) |
51.1 (4.5) | 44 (3.5) | 44.4 (3.3) | |||
NOTE. Change scores are shown for the performance-based measures (ARAT and BBT). Bolded values show clinically meaningful improvement.
Participant NS4 experienced minor skin discomfort during the fitting sessions and once at home using the NuroSleeve. This was resolved by smoothing a rough patch on the NuroSleeve, applying moleskin, and repositioning the participant's fingers within the device. There was 1 adverse event deemed unrelated to the intervention (breakthrough seizure due to known epilepsy). Participant NS7 exhibited a decrease in gross motor function (eg, lifting the hand to behind the head) over the course of the trial on the ARAT (baseline score 9 declining to 2, with or without the NuroSleeve), even though the ability to perform everyday bimanual activities were improved in the same duration on the COPM.
Discussion
Our preliminary findings demonstrate the feasibility of designing and fabricating the NuroSleeve, which improves upon the limitations of currently available UE orthoses and assistive systems. Incorporating 3D scanning and printing techniques with user-specific post-processing resulted in a NuroSleeve that was lightweight and comfortable for each user. The unique interdisciplinary and iterative design approach enabled real-time feedback from participants and clinicians to drive improvements. These improvements include changing the 3D print components to facilitate easier donning and doffing and adding more options for control. Further improvements to the NuroSleeve, including adding more proximal components (such as an elbow motor), are currently being developed.
At the beginning of the study, all participants exhibited severe levels of UE impairment as quantified on the baseline measures. With therapy intervention, all participants successfully learned how to use NuroSleeve to performance of activities and transitioned from using the NuroSleeve during supervised therapy to independent use at home. Overall, participants experienced a considerable improvement in both self-identified goals and functional outcomes. In COPM, ARAT, and ABILHAND, clinically meaningful improvements were seen in most or all participants. The most improvement was seen in COAs that measure hand function, which suggests the effectiveness of the NuroSleeve while in use.
Study limitations
One potential limitation was that some of the outcome measures did not provide an objective measure of NuroSleeve functionality. In addition, some of the tasks selected by participants in the COPM required more than improved grasp strength or hand function to achieve. For these tasks, such as throwing a ball, folding laundry, straightening the elbow, and turning a knob, it was difficult to differentiate what role or improvement, if any, the NuroSleeve may have made because completion of these tasks relied more on proximal strength than hand strength. Similarly, while the PROMIS UE-SF has been validated for use in people with stroke, its score reflects how easily a task can be completed, regardless of how it is completed: hence it cannot differentiate whether or how the assisting (non-affected) hand might be used for a given task. Many of the tasks evaluated (lifting a heavy object, changing an overhead lightbulb, and passing a turkey or ham to others at a table) required mobility and strength at the elbow and/or shoulder, and required use of the non-affected hand in addition to strength and function of the affected hand.
In addition, the sample size of 5 is not sufficient to perform meaningful statistical tests and we will need more participants to achieve statistical significance.
Future directions
These preliminary findings justify the continuation of this feasibility trial and the design of a future randomized, prospective trial. Because we cannot blind participants or therapists to the study intervention, an adaptive, cross-over trial design may be warranted. Finally, while mass practice without a device has appeal in principle, none of our current participants would have been able to make the time commitment that mass practice requires. Thus, a prospective control arm consisting of a matched number of sessions of OT without NuroSleeve may be the only way to determine whether the intervention (device use + therapy) would have a significant benefit over therapy alone. For future participants, we may select additional outcome measures that will focus specifically on the change in performance of the impaired limb while using the NuroSleeve.
One of our longer-term goals in developing the NuroSleeve is to make active, wearable UE movement restoration systems more accessible to the public. For any active UE movement restoration system to be widely scalable, financial barriers and technical support issues must be addressed. In addition, clinicians must become familiar with this technology, to see it not only as a viable tool that can be incorporated into rehabilitation therapy sessions, but also as a practical, assistive system that can be used at home to enhance independent function in ADLs. Our interdisciplinary approach involves clinicians in the design process, which will hopefully improve buy in and utilization. 3D printing allows for ease of manufacturing and customization, which we anticipate will decrease costs and, in turn, facilitate payer coverage once adequate prospective studies are completed.
Conclusions
We have designed, developed, and assessed the feasibility of independent home use of the NuroSleeve, an active UE movement restoration system customized for the user in form and function. It is lightweight, easy to don and doff, and is easily incorporated into therapy sessions and at home use during ADLs, thus overcoming many limitations of currently available UE orthoses and stimulators. We've also found success in our interdisciplinary and iterative design approach, which has enabled rapid and meaningful improvements to the NuroSleeve design. The clinical outcomes observed for the 5 participants suggest that the NuroSleeve improves functional performance of patients with UE impairment and enables them to engage in ADLs more actively. We will continue to refine and improve upon the NuroSleeve; work is underway to incorporate elbow and shoulder components to permit the user more degrees of freedom during functional tasks. We have also initiated a product development process so that future iterations of the NuroSleeve may be available to more individuals and potentially become part of clinical care.
Suppliers
-
a.
Chattanooga Continuum; DJO LLC.
-
b.
MyoWare 2.0; Advancer Technologies.
-
c.
BNO055, Bosch Sensortec GmbH.
-
d.
PSP Thumbstick; Adafruit Industries.
-
e.
V3; ELECHOUSE.
-
f.
“Wrist Driven Flexor Hinge”
-
g.
PA-07; Progressive Automations.
Acknowledgments
The authors would like to thank the members of the Raphael Center for Neurorestoration for their assistance with this project, particularly Joe Kardine for developing the occupational therapy protocol, Erica Jones for logistical support, Rachel Marie Zarin, Phyo Thuta Aung, and Mehdi Khantan for their technology development and contributions to the design, Nicole Gerhardt, Megan Vesey, Alison Bell, Jeremy Armstrong, and Yayoi Kumata for their clinical assistance, Aaron Roberts for clinical research support, Michelle A. Keon for general guidance and content editing, and Dr Robert H. Rosenwasser for support at the institutional level. Lastly, the authors are grateful for the time and dedication of each participant.
Footnotes
This research was supported by philanthropy to the Farber Institute of Neuroscience at Thomas Jefferson University.
Clinical Trial Number: NCT04798378.
Disclosures: M.D.S., A.N., and M.A. are inventors on a US provisional patent application that has been filed by Thomas Jefferson University on the methods described in this paper. All other authors report that they do not have any conflicts of interest with the research described.
Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.arrct.2023.100308.
Appendix. Supplementary materials
References
- 1.Laurent K, De Sèze MP, Delleci C, et al. Assessment of quality of life in stroke patients with hemiplegia. Ann Phys Rehabil Med. 2011;54:376–390. doi: 10.1016/j.rehab.2011.06.002. [DOI] [PubMed] [Google Scholar]
- 2.Virani SS, Alonso A, Benjamin EJ, et al. Heart Disease and Stroke Statistics-2020 Update: a report from the American Heart Association. Circulation. 2020;141:e139–e596. doi: 10.1161/CIR.0000000000000757. [DOI] [PubMed] [Google Scholar]
- 3.Stinear CM, Byblow WD, Ward SH. An update on predicting motor recovery after stroke. Ann Phys Rehabil Med. 2014;57:489–498. doi: 10.1016/j.rehab.2014.08.006. [DOI] [PubMed] [Google Scholar]
- 4.Sturm JW, Dewey HM, Donnan GA, Macdonell RAL, McNeil JJ, Thrift AG. Handicap after stroke: how does it relate to disability, perception of recovery, and stroke subtype?: the north East Melbourne Stroke Incidence Study (NEMESIS) Stroke. 2002;33:762–768. doi: 10.1161/hs0302.103815. [DOI] [PubMed] [Google Scholar]
- 5.Kim K, Kim YM, Kim EK. Correlation between the activities of daily living of stroke patients in a community setting and their quality of life. J Phys Ther Sci. 2014;26:417–419. doi: 10.1589/jpts.26.417. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Nam C, Rong W, Li W, et al. An exoneuromusculoskeleton for self-help upper limb rehabilitation after stroke. Soft Robot. 2022;9:14–35. doi: 10.1089/soro.2020.0090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Stein J, Narendran K, McBean J, Krebs K, Hughes R. Electromyography-controlled exoskeletal upper-limb-powered orthosis for exercise training after stroke. Am J Phys Med Rehabil. 2007;86:255–261. doi: 10.1097/PHM.0b013e3180383cc5. [DOI] [PubMed] [Google Scholar]
- 8.Alon G, Sunnerhagen KS, Geurts ACH, Ohry A. A home-based, self-administered stimulation program to improve selected hand functions of chronic stroke. NeuroRehabilitation. 2003;18:215–225. [PubMed] [Google Scholar]
- 9.Nicholls PB, Stevenson DA, Sherman ED, Lippay AL, Gingras G. A Canadian electric-arm prosthesis for children. Can Med Assoc J. 1967;96:1135–1140. [PMC free article] [PubMed] [Google Scholar]
- 10.McLean L, Scott RN. In: Powered upper limb prostheses. Muzumdar A, editor. Springer Berlin Heidelberg; Berlin, Heidelberg: 2004. The early history of myoelectric control of prosthetic limbs (1945-1970) pp. 1–15. [Google Scholar]
- 11.Page SJ, Hill V, White S. Portable upper extremity robotics is as efficacious as upper extremity rehabilitative therapy: a randomized controlled pilot trial. Clin Rehabil. 2013;27:494–503. doi: 10.1177/0269215512464795. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Kim GJ, Rivera L, Stein J. Poster 64 incorporating a wearable upper extremity robotics device into daily activities at home: a case series. Arch Phys Med Rehabil. 2013;94:e33–e34. [Google Scholar]
- 13.Peters HT, Page SJ, Persch A. Giving them a hand: wearing a myoelectric elbow-wrist-hand orthosis reduces upper extremity impairment in chronic stroke. Arch Phys Med Rehabil. 2017;98:1821–1827. doi: 10.1016/j.apmr.2016.12.016. [DOI] [PubMed] [Google Scholar]
- 14.Serruya MD, Napoli A, Satterthwaite N, et al. Neuromotor prosthetic to treat stroke-related paresis: N-of-1 trial. Commun Med (London) 2022;2:37. doi: 10.1038/s43856-022-00105-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Prosthesis: MedlinePlus Medical Encyclopedia. Available at: https://medlineplus.gov/ency/article/002286.htm. Accessed September 22, 2023.
- 16.CFR - Code of Federal Regulations Title 21. Available at:https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?CFRPart=890&showFR=1&subpartNode=21:8.0.1.1.32.4. Accessed September 22, 2023.
- 17.Keith MW, Peckham PH, Thrope GB, Buckett JR, Stroh KC, Menger V. Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand. Clin Orthop Relat Res. 1988:25–33. [PubMed] [Google Scholar]
- 18.Bionessrehab. Available at: https://bionessrehab.com/h200/. Accessed February 1, 2023.
- 19.Maier M, Ballester BR, Verschure PFMJ. Principles of neurorehabilitation after stroke based on motor learning and brain plasticity mechanisms. Front Syst Neurosci. 2019;13:74. doi: 10.3389/fnsys.2019.00074. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Backus D. Activity-based interventions for the upper extremity in spinal cord injury. Top Spinal Cord Inj Rehabil. 2008;13:1–9. [Google Scholar]
- 21.Grampurohit N, Bell A, Duff SV, et al. Highlighting gaps in spinal cord injury research in activity-based interventions for the upper extremity: a scoping review. NeuroRehabilitation. 2021;49:23–38. doi: 10.3233/NRE-210042. [DOI] [PubMed] [Google Scholar]
- 22.Anderson KD, Field-Fote EC, Biering-Sørensen F, et al. International spinal cord injury physical therapy-occupational therapy basic data set (Version 1.2) Spinal Cord Ser Cases. 2020;6:74. doi: 10.1038/s41394-020-00323-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Law M, Baptiste S, McColl M, Opzoomer A, Polatajko H, Pollock N. The Canadian occupational performance measure: an outcome measure for occupational therapy. Can J Occup Ther. 1990;57:82–87. doi: 10.1177/000841749005700207. [DOI] [PubMed] [Google Scholar]
- 24.Eyssen ICJM, Beelen A, Dedding C, Cardol M, Dekker J. The reproducibility of the Canadian Occupational Performance Measure. Clin Rehabil. 2005;19:888–894. doi: 10.1191/0269215505cr883oa. [DOI] [PubMed] [Google Scholar]
- 25.McColl MA, Carswell A, Law M. CAOT; 2006. Research on the Canadian Occupational Performance Measure: an annotated resource. ISBN: 1895437652, 9781895437652. [Google Scholar]
- 26.McColl MA, Denis CB, Douglas K-L, et al. A clinically significant difference on the COPM: a review. Can J Occup Ther. 2023;90:92–102. doi: 10.1177/00084174221142177. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Yozbatiran N, Der-Yeghiaian L, Cramer SC. A standardized approach to performing the action research arm test. Neurorehabil Neural Repair. 2008;22:78–90. doi: 10.1177/1545968307305353. [DOI] [PubMed] [Google Scholar]
- 28.van der Lee JH, Roorda LD, Beckerman H, Lankhorst GJ, Bouter LM. Improving the Action Research Arm test: a unidimensional hierarchical scale. Clin Rehabil. 2002;16:646–653. doi: 10.1191/0269215502cr534oa. [DOI] [PubMed] [Google Scholar]
- 29.McDonnell M. Action research arm test. Aust J Physiother. 2008;54:220. doi: 10.1016/s0004-9514(08)70034-5. [DOI] [PubMed] [Google Scholar]
- 30.Platz T, Pinkowski C, van Wijck F, Kim I-H, di Bella P, Johnson G. Reliability and validity of arm function assessment with standardized guidelines for the Fugl-Meyer Test, Action Research Arm Test and Box and Block Test: a multicentre study. Clin Rehabil. 2005;19:404–411. doi: 10.1191/0269215505cr832oa. [DOI] [PubMed] [Google Scholar]
- 31.Van der Lee JH, De Groot V, Beckerman H, Wagenaar RC, Lankhorst GJ, Bouter LM. The intra- and interrater reliability of the action research arm test: a practical test of upper extremity function in patients with stroke. Arch Phys Med Rehabil. 2001;82:14–19. doi: 10.1053/apmr.2001.18668. [DOI] [PubMed] [Google Scholar]
- 32.Mathiowetz V, Volland G, Kashman N, Weber K. Adult norms for the box and block test of manual dexterity. Am J Occup Ther. 1985;39:386–391. doi: 10.5014/ajot.39.6.386. [DOI] [PubMed] [Google Scholar]
- 33.Chen H-M, Chen CC, Hsueh I-P, Huang S-L, Hsieh C-L. Test-retest reproducibility and smallest real difference of 5 hand function tests in patients with stroke. Neurorehabil Neural Repair. 2009;23:435–440. doi: 10.1177/1545968308331146. [DOI] [PubMed] [Google Scholar]
- 34.Gustafsson S, Stibrant Sunnerhagen K, Dahlin-ivanoff S. Occupational therapists’ and patients’ perceptions of ABILHAND, a new assessment tool for measuring manual ability. Scand J Occup Ther. 2004;11:107–117. [Google Scholar]
- 35.Ekstrand E, Lindgren I, Lexell J, Brogårdh C. Test-retest reliability of the ABILHAND questionnaire in persons with chronic stroke. PM R. 2014;6:324–331. doi: 10.1016/j.pmrj.2013.09.015. [DOI] [PubMed] [Google Scholar]
- 36.Wang T, Lin K, Wu C, Chung C, Pei Y, Teng Y. Validity, responsiveness, and clinically important difference of the ABILHAND questionnaire in patients with stroke. Arch Phys Med Rehabil. 2011;92:1086–1091. doi: 10.1016/j.apmr.2011.01.020. [DOI] [PubMed] [Google Scholar]
- 37.Hung M, Voss MW, Bounsanga J, Crum AB, Tyser AR. Examination of the PROMIS upper extremity item bank. J Hand Ther. 2017;30:485–490. doi: 10.1016/j.jht.2016.10.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Cook KF, Bamer AM, Amtmann D, Molton IR, Jensen MP. Six patient-reported outcome measurement information system short form measures have negligible age- or diagnosis-related differential item functioning in individuals with disabilities. Arch Phys Med Rehabil. 2012;93:1289–1291. doi: 10.1016/j.apmr.2011.11.022. [DOI] [PubMed] [Google Scholar]
- 39.Kazmers NH, Qiu Y, Yoo M, Stephens AR, Tyser AR, Zhang Y. The minimal clinically important difference of the PROMIS and quickdash instruments in a nonshoulder hand and upper extremity patient population. J Hand Surg Am. 2020;45:399–407.e6. doi: 10.1016/j.jhsa.2019.12.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.JAECO Orthometry Form. Available at: https://jaecoorthopedic.com/wp-content/uploads/2020/02/Jaeco-Orthometry-Form.pdf. Accessed November 15, 2022.
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.





