TABLE 3.
Neutralizing tests at 1,000 TCID50 per wella
| No. of injectionsbefore bleeding | Neutralizing titerb (avg of 2 expt) |
|---|---|
| 0 (preimmune serum) | 0 |
| 4 | 30 |
| 6 | 66.8 |
| 8 | 112 |
| 12 | 67.2 |
| 14 | 98 |
| 16 | 189.2 |
Neutralizing tests were done using a 96-well plate at 1,000 TCID50 per well.
Determined by the Reed-Muench method.