Table 2.
EPANET simulation model for DMA-1.
| Parameter | Value |
|---|---|
| Distribution mains | ductile iron pipe, nominal diameter 250 mm HDPE pipe, nominal diameter 160 mm length 1325 m |
| Branch pipe | HDPE pipes, nominal diameters 90 mm or 63 mm length 5323 m |
| Number of pipes | 148 |
| Hazen Williams C | 100 for DI pipes and 140 for the HDPE pipes |
| Ground levels | 7 m at the DMA inlet, 5–9 m at the junctions |
| Water head at the inlet | Varied at five levels between 22 m and 32 m |
| Number of nodes (junctions) | 121 |
| Node demand (base demand) | Varied at five levels in 16.26–23.64 m3/d The total demand was allocated equally to all nodes. |
| Emitter coefficient | Simulated at three levels: 0.5, 1.0, and 1.5 Assigned to all nodes. |
Note: The EPANET model is based on the DMA design map; hence, the total pipe length of the model (6648 m) was shorter than the final pipe length of DMA-1 (9141 m).