Skip to main content
[Preprint]. 2023 Dec 13:rs.3.rs-3725688. [Version 1] doi: 10.21203/rs.3.rs-3725688/v1

Table 2. Thresholds for plasma pTau217, pTau181 and Aβ1–42/Aβ1–40 to detect A + participants.

pTau217: phosphorylated tau 217, pTau181: phosphorylated tau 181.Aβ1–42: Amyloid β1–42. Aβ1–40: Amyloid p1–40. NPV, negative predictive value. PPV,positive predictive value. Threshold units for pTau are in pg/mL.

Accuracy of plasma pTau217
Threshold Sensitivity Specificity NPV PPV Youden Accuracy
0.130 97.8% 65.5% 96.9% 73.1% 0.634 81.3%
0.186 95.0% 82.1% 94.4% 83.5% 0.770 88.4%
0.247 90.6% 89.7% 90.9% 89.4% 0.803 90.1%
0.249 89.9% 89.7% 90.3% 89.3% 0.796 89.8%
0.388 69.8% 95.2% 76.7% 93.3% 0.650 82.7%
0.552 45.3% 97.2% 65.0% 94.0% 0.426 71.8%
Accuracy of plasma pTau181
Threshold Sensitivity Specificity NPV PPV Youden Accuracy
1.573 97.9% 32.0% 94.1% 57.3% 0.299 63.8%
1.740 95.0% 44.7% 90.5% 61.6% 0.397 69.0%
2.125 90.0% 71.3% 88.4% 74.6% 0.613 80.3%
2.815 64.3% 90.0% 73.0% 85.7% 0.543 77.6%
3.345 47.9% 94.7% 66.0% 89.3% 0.425 72.1%
3.840 31.4% 97.3% 60.3% 91.7% 0.288 65.5%
Accuracy of Aβ1–42/Aβ1-40
Threshold Sensitivity Specificity NPV PPV Youden Accuracy
0.086 97.9% 41.3% 95.4% 60.9% 0.392 68.6%
0.080 95.0% 65.3% 93.3% 71.9% 0.603 79.7%
0.078 90.0% 75.3% 89.0% 77.3% 0.653 82.4%
0.073 65.0% 90.0% 73.4% 85.8% 0.550 77.9%
0.070 37.9% 94.7% 62.0% 86.9% 0.325 67.2%
0.067 20.7% 97.3% 56.8% 87.9% 0.180 60.3%