Abstract
Arsenic is a hazardous element that causes environmental pollution. Due to its toxicological effects, it is crucial to quantify and minimize the hazardous impact on the ecology. Despite the significant advances in analytical techniques, sample preparation is still crucial for determining target analytes in complex matrices. Several factors affect the direct analysis, such as trace-level analysis, advanced regulatory requirements, complexity of sample matrices, and incompatible with analytical instrumentation. Along with the development in the sample preparation process, microextraction methods play an essential role in the sample preparation process. Microextraction techniques (METs) are the newest green approach that replaces traditional sample preparation and preconcentration methods. METs have minimized the limitation of conventional sample preparation methods while keeping all their benefits. METs improve extraction efficacy, are fast, automated, use less amount of solvents, and are suitable for the environment. Microextraction techniques with less solvent consumption, such as solid phase microextraction (SPME) solvent-free methods, and liquid phase microextraction (LPME), are widely used in modern analytical procedures. SPME development focuses on synthesizing new sorbents and applying online sample preparation, whereas LPME research investigates the utilization of new solvents.
Keywords: Arsenic, sample preparation, preconcentration, solid-phase microextraction, liquid-phase microextraction
1. Introduction
Arsenic is the most hazardous element spread as a result of natural occurrences and anthropogenic actions. It has received a lot of attention worldwide due to its toxicological effect. In aquatic environments, its presence can be attributed to various sources such as surface weathering, underground deposits of arsenic-rich geological sources, biological activities, volcanic emissions, and anthropogenic activities [1]. Arsenic compounds are used in various industries, such as herbicide/pesticide production, mining operations, semiconductor manufacturing, and wood preservation. Arsenic (As) concentration in the environment has risen above a WHO-permissible level, which causes long-term mutilation, and about 250 million people worldwide have been affected by its toxicity [2,3]. As exposure can result in significant health problems such as cardiovascular illnesses, neurological disorders, hematological impacts, and lung, bladder, kidney, and liver malignancies. In 2001, the USEPA and the WHO decreased the permissible limit of As in fresh water from 50 ug/L to 10 ug/L [4]. To minimize the toxic effects of As on humans, it is necessary to monitor the quantity of As in the environment [5]. Several analytical methods have been reported for the elimination and quantification of As, such as GF-AAS [6], AFS [7], and ICP-OES [8]. ICP-MS [9], GC [10], HPLC [11,12], and CE [13], coprecipitation [14], and solvent extraction techniques (liquid-liquid extraction and dispersive liquid-solid phase sorbent-based extraction). Despite the significant development in analytical methods, sample preparation is still crucial for determining target analytes in complex matrices [15–17].
The abovementioned sample pretreatment techniques have some drawbacks, such as being time-consuming and expensive and using a larger amount of volatile solvents. Researchers focus on developing new, economically beneficial, easy-to-operate, and fast operation processes and environmentally friendly methods that fulfil the rules of Green Analytical Chemistry (GAC). GAC has become more important and significantly impacted all analytical methods. GAC principles focus on reducing energy use, miniaturizing the methods to be simpler and more automated, using less toxic reagents, integrating analytical methods, minimizing the sample size, and not needing derivatization [18]. Analytical methodologies and techniques have been seriously promoted and developed due to the advancement in information and instrumental technologies [19]. More work is being done to improve sample preparation, and advancements in analytical chemistry are moving toward making the sample preparation stage for analysis more environmentally friendly. Several methods have been reported to prepare samples “green” [20], but one of the most important goals is to reduce the size of analytical processes and make them faster and easier. The next important thing is to use green media instead of volatile solvents, such as ionic liquids, agro solvents, and supercritical fluids. Different factors affect the sample preparation process, such as microwave and UV radiation, high temperature and pressure, and ultrasound energy. It is essential to optimize these parameters to obtain excellent extraction efficiency. Therefore, it is important to develop a way to prepare samples that keeps the effective ingredients at the highest level and separates and eliminates the ineffective ingredients and impurities [19,20]. Different modern extraction methods have been widely used for sample preparation. For example, solid phase microextraction (SPME) and liquid phase microextraction (LPME) fulfil the requirements of researchers and also are in line with the rules of GAC; they are a miniaturized form of SPE and LPE techniques; they are fast, easy, environmentally friendly, and economically beneficial. These have the highest score in comparing analytical procedures because they are more environmentally friendly and cost-effective [21–24]. In addition, microextraction methods have higher selectivity and sensitivity, with excellent extraction performance and enrichment factors. Figure 1 represents arsenic extraction methods.
Figure 1.
Different methods used for the extraction of As.
2. Microextraction techniques
Sample preparation is crucial in sample analysis, but it takes too much time and requires extra protocols. The traditional methods for preparing samples are not in line with the goals of GAC because they use a lot of volatile solvents, produce dangerous wastes, and harm the environment [25]. Microextraction techniques (METs) are the newest green approach that replaces traditional sample preparation and preconcentration methods [26,27]. METs have minimized the limitation of conventional sample preparation methods while keeping all their benefits. METs are the miniaturized form of basic extraction methods, like SPE and LLE [28]. Even though METs can be very different, they all have something in common. For example, they improve extraction efficacy, are fast, automated, use less amount of solvents, and are suitable for the environment [29].
One of the most important things that affect how well METs work is the choice of the proper extraction phase. At the moment, METs use several adsorbents and solvents as extraction media [30]. One of the critical steps in microextraction is sample preparation and analysis. Quantitative analyses often rely heavily on the precision and accuracy of sample preparation. The pretreatment performance aims to eliminate interference from potential species and boost the final signal of the analyte through amplification. Preconcentration of the targeted analyte through extraction from a complex matrix into a small volume of extracting solvents can improve the analytical signal. Through the use of a suitable sample preparation method, it will be possible to analyze more complex samples and minute quantities of the objective analyte. Analyte transfer from the first solution into a second phase is the basis of all sample preparation techniques. The second phase, the acceptor phase or the extracting phase, must be compatible with the final analysis instrument (for instance, an aqueous acceptor phase cannot be injected into a gas chromatograph). In addition, the analyte needs to be soluble enough in the extracting phase, and picking an extracting phase with a low enough volume can cause preconcentration of the analyte [31]. Minimal amounts of solid adsorbent are used in SPME for analyte extraction.
A few microliters of a solvent could be used to desorb the sorbent before GC analysis, or the sorbent could be introduced directly. This method is fast compared to the SPE, in contrast to SPME. This technique simplifies the sample preparation process and minimizes interferences during the complex sample analysis. METs can be generally categorized into two groups: LPME and SPME. Pawliszyn et al. initially presented the SPME method in 1990 [32]. This method separates the analyte into a sample and an extracting phase on a fused silica fiber [33]. Figure 2 shows the general schematic diagram of the microextraction of As.
Figure 2.
Schematic representation of microextraction of As.
2.1. LPME
LPME has been widely used for the sample preparation process due to its quick phase transportation, high extracting efficiency, ease of modification, and the possibility of direct injection of the final phase for analysis; it is the cheaper, highly stable extracting phase, and has memory effects. The LPME method can be hyphenated with modern analytical techniques such as GC, HPLC, and CE [19]. While there are many other important techniques, the most common LPME methods are SDME, DLLME, and HF-LPME. Several methods have been proposed to stabilize the extracting phase, prepare separated phases, and improve extraction efficacy in LPME; this is only possible on a microliter scale. The extracting phase in two-phase LPME comes into direct contact with the sample solution, which can speed up the extraction process but also lowers selectivity, necessitates more extensive sample clean-up, and restricts the extracting solvent to water-immiscible organic liquids. In contrast, a third solvent was used in three-phase LPME that is immiscible with both the sample solution and the final acceptor phase. This arrangement significantly improves the method’s selectivity and enables using the aqueous acceptor phase. In low-pressure, in mixed-element LPME reactors, the liquid extraction phase is stabilized. Additionally, some LPME methods were developed to expand the contact area between the phases and boost the extraction driving force, both of which contribute to the overall speed and efficiency of the process [34]. The LPME technique preserves the analyte’s relatively high EF while combining sampling, isolation, extraction, and concentration in a single step. LPME has been utilized for several different things, including the extraction of analytes from water samples, including organic substances such as pesticides [35], polycyclic aromatic hydrocarbons (PAH) [36], personal care products and pharmaceuticals [37], and sulfur-based compounds [38], toxic metal ions like As3+ and As5+ [39, 40], vanadium [41], and fluorine [42]. The LPME technique is frequently used with samples with complex matrixes identified by their diverse, low-level component contents. These samples include natural products [43], food [44], and biological samples [45]. They highlight the potential of LPME techniques as a potential sample preparation tool in complex sample analysis. Different types of LPMEs, such as SDME, HF-LPME, and DLLME, are the three main categories to increase the stability and dependability of LPME; the extraction phase is housed inside a porous hollow polypropylene fiber using this method [46]. The foundation of DLLME is the application of a dispersive extraction solvent. When the water sample is mixed with the extraction solvent, droplets of the extractant can form. This method expedites the movement of analyte from the sample to the extraction stage [47]. All METs rely on transporting sample-bound analytes into an acceptor-phase reaction for extraction on liquid or solid phase. All these methods work well and fulfill the needs of modern eco-friendly analytical procedures [48].
2.1.1. Single-drop microextraction
SDME was proposed to address the issue of the increasing size of the extraction solvent [49]. Analytes in the sample solution are thought to be partitioned into the extractant solvent droplet dangling from the syringe needle tip, making SDME possible. The extracting phase can contact the sample solution or headspace [50]. Traditional SDME was an innovative LLE-based technique, but newer setups have been created to make the process easier and less cumbersome. In response to this problem, Zhang et al. [51] proposed ultrasonic nebulized headspace solid-phase microextraction (HS-SDME). They demonstrated that the analyte’s gas-liquid distribution equilibrium is rapidly attained and enhanced by forming an “ultrasonic fountain” through ultrasonic vibration through solvent extraction.
Zhang et al. [52] presented a dynamic format similar to linking the evaporated species to the extracting droplet. As a sample pretreatment, extraction, and preconcentration method, SDME has achieved near-universal acceptance. However, due to the two-phase extraction mechanism, its direct immersion mode is less selective and has less clean-up ability. In addition, nonvolatile compounds cannot be extracted using the headspace mode. By suspending the extracting droplet in an organic liquid membrane, Cantwell first introduced the three-phase format of SDME using an optical probe as the microdrop holder; online monitoring of the target analyte by UV/Vis detection was also presented following SDME procedure [53].
2.1.2. Dispersive liquid-liquid microextraction
The DLLME technique is implemented by inducing the formation of tiny droplets of an organic solvent that acts as an extracting agent within the sample. This is achieved by utilizing a disperser solvent that exhibits complete miscibility in both the aqueous and organic phases. The extensive contact surface area between the model and the extracting degree facilitates the efficient extraction of the target analytes. Novel advancements in the DLLME configuration have been introduced to streamline and expedite the extraction procedure [54]. Ebra Himpour et al. [55] proposed a novel approach to address the time-consuming centrifugation step in the DLLME method, which involves the separation of the dispersed solvent for phase separation. The proposed process uses an in-line filter to separate the organic extracting phase from the aqueous sample.
Furthermore, the utilization of hollow fiber was employed for phase collection extraction. The elution of fiber was carried out using acetonitrile, and the resulting solution was subsequently introduced into the analysis instrument [56]. Lopes et al. [57] employed a combined hollow fiber-dispersive liquid-liquid microextraction (DLLME) technique to extract and collect analytes simultaneously. This involved inserting a hollow fiber with a porous wall impregnated with 1-octanol into the sample containing the extractor and disperser solvent mixture at the onset of the extraction process. The analytes were extracted from the membrane through liquid desorption, which was carried out by introducing acetonitrile.
2.1.3. Hollow fiber liquid-phase microextraction
The initial application of hollow fiber-based liquid-phase microextraction (HF-LPME) was aimed at facilitating a liquid-liquid microextraction process involving three phases. Hollow fiber presents two distinct partitions, the wall pores and the lumen, which can accommodate a single extracting solvent or two nonmixing solvents for two-phase or three-phase extractions, respectively [58]. The extraction solvent is stabilized, and leakage is prevented during the process due to the porous nature of the hollow fiber. Therefore, this methodology has the potential to be replicated and yield greater precision when contrasted with SDME. The initial three-phase liquid-liquid microextraction (HF-LPME) was documented to have employed an organic solvent and an aqueous solution. Alternatively, using two immiscible organic solvents, the three-phase approach in HF-LPME is feasible [59]. The HF-LPME method, compatible with gas chromatography, utilized n-dodecane and either acetonitrile or methanol as solvents in the wall pores and lumen, respectively. The extracted phase was drained from the lumen and injected into the analysis instrument. Dynamic HF-LPME can enhance analyte mass transfer and accelerate extraction. Various configurations were introduced to facilitate the dynamic movement of the sample solution or acceptor phase [60]. The dynamic device developed by Pimparu involved the sample solution’s initial passage through the hollow fiber’s lumen, thereby facilitating the diffusion of the analyte into the immobilized organic solvent. Subsequently, the lumen was extracted using the final solution, and the resulting solution was introduced into the analytical apparatus [60]. HF-LPME is a viable microextraction methodology for examining intricate matrices or when the sample solution is available in a restricted volume. Despite the advancements made in HF-LPME, this technique continues to be hindered by its reliance on a passive diffusion-based extraction mechanism that operates relatively slowly.
Table 1 represents the application of LPME for arsenic species [61–81].
Table 1.
The application of LPMEfor arsenic species.
| Extraction phase | Analyte | Matrix | Technique | EF | LOD (ng/L) | Reference |
|---|---|---|---|---|---|---|
| AgDDC–pyridine:benzyl alcohol | As3+ As5+ | Water samples | HS-SDME–ETAAS | 150 | 45 | [61] |
| Pd(II) aqueous drop | As3+ As5+ | Water samples | HS-SDME–ETAAS | 70 | 100–150 | [62] |
| Aqueous drop | As3+ | NWRI TM-28.3 CRM | HS-SDME–GC–ICP-MS | 9.85 | 0.2 | [63] |
| Toluene | As3+ As5+ | Fresh water Human hair | HF-LPME–ETAAS | 78 | 0.12 | [64] |
| CCl4 | As3+ | Water samples | ETAAS | 115 | 10.50 | [65] |
| DSPME | As3+ As5+ | Water, urine, and rice | ETAAS | 0.01 | [66] | |
| CdS NPs | As3+ As5+ | Water and food | ICP-OES | 0.0005–0.0008 | [67] | |
| G/CeO2 | As5+ | Water | EDXRF | 0.10–0.21 | [68] | |
| [C4MIM][PF6] | As | Eye makeup | ETAAS | 0.049–0.262 | [69] | |
| IL-DLLME | As3+ As5+ | White and red wine | ET-AAS | 46 | 0.005 | [70] |
| IL-LPME | As3+ As5+ | Bottle, river, rain, tap water | ET-AAS | 130 | 0.002 | [71] |
| IL-DLLME | As3+ As5+ | Tap and river water | ET-AAS | 255 | 0.01 | [72] |
| DLLME | As3+ | Water | ETV-ICP-MS | 60 | 0.0005 | [73] |
| SBME | As3+ As5+ | Synthetic, lake and tap water | ETV-ICP-MS | 220 | 0.0003 | [74] |
| USE-SFODME | As3+ As5+ | Sea, river, tap water | ET-AAS | 152 | 0.004 | [75] |
| Alkanol-based reverse micelle-SPME | As | Water | Spectrophotometry | 0.4 | [76] | |
| DLLME | As, | Honey | ETAAS | 110 | 12 | [77] |
| DLLME. | As3+ As5+ | Water | GFAAS | 45 | 0.036 | [78] |
| DLLME | As3+ As5+ | Water | GFAAS | 115 | 0.01 | [79] |
| In-tube HF-SPME | As | Human urine | ICP-MS-IP-RP-HPLC | 4–19 | 0.017–0.053 | [80] |
| DLLME | As3+ As5+ | Fruit juices | HG-AFS | 10 | [81] |
2.2. SPME
SPME is an emerging extraction technique introduced in 1990 [82]. SPME has been recognized as a modern alternative to conventional sample preparation techniques and exhibits various potential applications [83–85]. The SPME methodology entails the adsorption of the desired analytes onto the exterior of a fiber that has been coated. After the extraction process, the analytes that have been trapped are subjected to desorption in order to facilitate their analytical determination. The desorption process is commonly executed through a thermal technique, whereby the SPME fiber is inserted into the injection port of the GC. The SPME method combines with LC or CE. The SPME coating material can maintain its structural integrity during desorption, enabling autonomous operation and repeated utilization. For instance, an appropriate sorbent must be chosen to successfully apply the aforementioned SPME procedures in various settings. Other essential factors have been optimized in the SPME process for the selective extraction, reusability, and disposal of the sorbents with multiple analytes in environmental samples [86]. Due to its benefits, SPME has emerged as a viable alternative for detecting and specifying heavy metals. Fiber-based SPME [87], in-tube SPME [88], in-tip SPME [89], stir sorptive bar extraction [90], and dispersive SPME [91] are the five most common ways to run SPME. Over the past decade, several papers are detailing the utilization of SPME in environmental analysis. The comprehensive establishment of the SPME technique needs several intermediary procedures spanning from sample acquisition to conclusive outcomes, encompassing sample pretreatment, SPME, desorption, and detection. The objective of this particular stage is to purify and enhance the sample, thereby achieving high selectivity and sensitivity. Several SPME configurations have been devised to achieve this objective, including in-tube, fiber, in-needle, in-tip, thin-film, and stir-bar microextraction. The selection of configurations can be tailored to a particular objective, considering their respective benefits and drawbacks. One of the benefits of SPME is its solvent-free nature, making it a more environmentally friendly option [23].
Additionally, SPME is an online method, allowing for real-time analysis. Furthermore, this technique is particularly well-suited for the study of volatile compounds. The first method relies on directly immersing the adsorptive materials into the samples. In contrast, the second method relies on the adsorptive extraction of volatile or semivolatile molecules from the headspace of the samples. In both instances, the utilization of adsorbent materials has served as a driving force behind the researchers’ efforts to enhance the effectiveness and selectivity of the SPME procedures.
2.2.1. Direct immersion method (DI-SPME)
The DI-SPME technique involves the direct interaction of the adsorbent materials with the sample matrix that offers the desired analytes. It is imperative for adsorbent materials to effectively isolate all target analytes in a given sample while eliminating any interfering compounds from the matrix. Regarding this matter, the adsorbent materials must possess adequate sorption capacity to adsorb all the intended analytes and exhibit targeted interaction. Subsequently, the complete release of the target analytes can be achieved through elution by an organic solvent or an increase in temperature before their introduction into the detection system. Moreover, implementing new adsorbent materials, such as nanomaterials (NMs) with elevated surface areas, may represent an optimal approach for enhancing sorption capacity. Nanosorbents are widely utilized in environmental contexts due to their characteristics, including high sorption capacity and, in certain instances, high selectivity [92].
2.2.2. Headspace method (HS-SPME)
The experimental procedure involves the placement of the sample into a vial that is subsequently sealed with a cap. The target volatile or semivolatile analytes are extracted by exposing the adsorbent materials to the sample’s headspace, which may be in a gas, solid, or liquid state. This approach enhances selectivity by mitigating the impact of the high number of volatile substances in environmental samples. The optimal nanomaterials for headspace (HS-SPME) are identical to the adsorbents utilized in the direct immersion (DI-SPME) technique. The desorption process employed in HS-SPME typically involves thermal desorption, necessitating that the nanomaterials exhibit robust chemical and thermal stability at the relevant desorption temperatures. SPME remains the most commonly used microextraction technique [93]. The SPME device, widely found in both classical and commercial contexts, comprises a fiber of fused silica or stainless steel coated or uncoated with a thin sorbent layer. The fiber is attached to a device that resembles a syringe. Researchers have employed various techniques to enhance the efficiency of SPME in environmental contexts by utilizing numerous adsorbent materials such as polymeric materials, molecularly imprinted polymers, and nanomaterials. The utilization of NMs in SPME methods has garnered significant interest in the analytical and environmental domains owing to their improved characteristics and ability to provide high selectivity for specific analytes. The utilization of SPME by NMs for ecological sample clean-up and pretreatment is experiencing a rise in interest [94]. Table 2 shows the application of SPME for arsenic speciation [11,67,80,95–102]
Table 2.
The application of SPME for arsenic species.
| Extraction phase | Adsorbent | Analyte | Matrix | Technique | EF | LOD (ng/L) | Reference |
|---|---|---|---|---|---|---|---|
| DMSPE | GO-SH | As | Water | TXRF | 150 | 0.05–0.1 | [11] |
| Ultrasound-assisted DSPME | CdS nanoflowers | As3+ As5+ | Water, Food | ICP-OES | 0.8 and 0.2 | [67] | |
| In-tube HF-SPME | MPTS–AAPTS/PSP | As3+ | Human urine | IP-RP-HPLC | 19 | 0.5 | [80] |
| DLLME/DMSPE | Magnetic MWCNTs | As | Cow milk, fish liver, and water | ET-AAS | 398–403 | 0.003–0.005 | [95] |
| UA-DMSPE | G-COOH | As3+ As5+ | Water and human serum/urine | FI-HG-AAS | 5.0–50 | 0.002–0.02 | [96] |
| HS-SPME | CAR/PDMS | As | Baker yeasts | ICP-OES | 0.1–0.8 | [97] | |
| USA-DSLMPME | (NH2-UVM7) | As3+ As5+ | Water and urine | ET-AAS | 100 | 0.02–1.65 | [98] |
| Dμ-SPE | (FTGCNCs) | As3+ As5+ | Water | ICP-MS | 1.2 | [99] | |
| MSPME | Magnetic metal-organic framework composite (MFC) and mercapto-functionalized MFC nanoparticles (MFC-SH) | As3+ As5+ | Water | ICP-MS | 23–25 | 7.1 | [100] |
| SPME | N-(β-aminoethyl)-γ-aminopropyltriethoxysilane (AEAPTES) | As3+ As5+ | Water | ICP-MS | 60 | 0.005 | [101] |
| SPME | Polystyrene polydimethyl siloxane polymer | As3+ | Water | ET-AAS | 218 | 6.9 | [102] |
3. Arsenic speciation using different modern sample preparation techniques
The primary origin of inorganic arsenic is attributed to rock weathering in nature, while anthropogenic activities also contribute to its release. The occurrence of inorganic arsenic in groundwater is predominantly in the nonionic trivalent (As(III)) and ionic pentavalent (As(V)) forms, with varying proportions depending on the environmental conditions of the aquifer [103]. Determining arsenic speciation in water is commonly regulated by factors such as redox conditions, pH, biological activity, and adsorption reactions [104–106]. Under low Eh conditions, arsenic is transformed into its As(III) form, whereas under high Eh conditions, As(V) is the predominant arsenic species. According to research, As(III) is more hazardous than As(V) and poses a challenge in terms of its elimination from water using conventional methods [107,108]. Typically, the elimination of As(III) involves an initial oxidation to As(V), followed by the removal of As(V) through adsorption, precipitation, or ion exchange techniques [10]. The environment is exposed to organic arsenic species, specifically monomethyl arsenic acid (MMA) and dimethylarsinic acid (DMA), primarily as a result of agricultural and industrial practices [11]. MMA and DMA are active constituents in weed control and defoliation agents frequently employed before cotton harvesting. These constituents have been identified as problematic pollutants in groundwater at locations where pesticide manufacturing and inappropriate disposal practices have been carried out, as per previous research [12]. The methylation process of inorganic arsenic has been suggested as a potential biological mechanism for detoxification. However, recent studies have revealed that methylated arsenic species can induce DNA damage, chromosomal aberrations, and tumor promotion in rodents [13,14]. Although natural waters are primarily composed of inorganic species, the occurrence of MMA and DMA has also been documented in the literature [12,15].
Arsenic toxicity is primarily influenced by its chemical composition and degree of oxidation. Arsenite As3+ and arsenate As5+ are regarded as toxic and carcinogenic forms. Arsenocholine (AsC) and arsenobetaine (AsB) are regarded as nontoxic arsenic compounds. In contrast, monomethyl arsenic acid (MMA) and dimethylarsinic acid (DMA) are less toxic than inorganic arsenic species As3+, As5+, MMA, DMA, AsC, and AsB. [109]. As3+ accumulates quickly in biological systems. Both oxidation states prevent the mitochondria from performing tasks that require energy. As3+ substances have a strong affinity for the sulfhydryl groups of proteins and render enzymes inactive. As5+ competes with phosphate in cellular reactions and can decouple oxidative phosphorylation, causing the high-energy bonds of adenosine triphosphate to be broken. As can generally lead to both acute and chronic poisoning. According to recent studies, trivalent methylated arsenic species are more toxic than their inorganic counterparts. The quantification of total As cannot aid as a reliable data source on As toxicity. Total As could be determined until 1973, but since then, As3+ and As5+ species have been determined using the hydride formation technique [110]. Altunay et al. [111] reported that VA-LPME is based on the DES (DES-VA-LPME) for the sample preparation and preconcentration of As from honey water and rice. AAS-EDDS have been used for the quantification of As from the prepared sample. Different parameters like pH, DES type, chelating agent amount, emulsifier agent’s quantity, molar ratio and volume, sample volume, and vortex time have been optimized to attain the maximum efficiency of the proposed sample. The DES-VA-LPME method has obtained a LOD of 6.5 ng/L, a quantification limit of 20 ng/L, and an EF of 70. The proposed method has been successfully used to extract As from real samples. Jiang et al. [64] proposed an HF-LPME method using ammonium pyrrolidine dithiocarbamate (APDC) as an extractant material for eliminating As3+ and As5+. For the quantification of As3+ and As5+, ETAAS has been used. Different factors have been optimized to obtain maximum extraction efficiencies, such as pH, selection of organic solvent, the volume of APDC, stirring rate, and time study. At the optimized conditions, the detection limit was up to 0.12 ng/mL with an EF 78, and the LOD value was 5 ng/mL. The developed method has been used to determine the As3+ and As5+ in hair, fresh water, and spiked samples; the percentage recovery was obtained up to 86%–109%. Chamsaze et al. [61] developed HS-SPME to extract As from water samples. GF-AAS has been used for the quantification of As. The typical concentration was 30 pg/mL, equal to a typical mass of 0.12 pg/mL, and the calibration curve was linear from 45 pg/mL to 4 ng/mL. The testing results for As in tap water, reference materials, and washing machine powder showed that the method presented was accurate, obtained good results, and was applied in real application. Haghnazari et al. [112] proposed a counter-current liquid-liquid microextraction (CLLME) based new method for eliminating As from biological samples such as plasma and urine. ETAAS have been used for the quantification of As. The LODs) were found up to 0.03–0.05 g/L and linear in the 0.1–50 g/L range; EF ranged from 198 to 212 and 220 to 240, respectively. Based on seven replicate measurements of 5.0 g/L of As, the method’s repeatability (intraday) and reproducibility (interday) fell between 2.3% and 3.5% and 4.0% and 5.7%, respectively. The developed method for speciation of As from plasma and urine was found to have excellent capability, as evidenced by the percentage recovery obtained up to the 92%–107% range. Majumder et al. [113] reported an HF-LPME-based method for extracting As from water samples. TXRF spectrometry has been used for the analysis of As. Relevant experimental parameters have been evaluated during As extraction, such as pH, extractant type, solvent type, and agitation time; it was observed that As3+ extraction was more efficient at pH 13, whereas As5+ extraction was best at pH 8.5. The proposed method was also used to preconcentrate and determine As from environmental samples. Zeng et al. [114] used Triton X-100-based HF-LPME to eliminate As from biological and environmental samples. FAAS has been used for the determination of As. Triton X-100 was utilized as an adsorbent. Under the optimal conditions, the LOD for As3+ was up to 0.08 ng/mL, the EF was up to 280, and the RSD was 5.2% for five replicate measurements of 10 ng/mL. The developed method obtained good results during the analysis of As3+ and As5+ from the biological and environmental samples. Yilmaz et al. [115] reported a novel approach merging the principles and benefits of the SPME method, hydrolytic enzymes, and ultrasonic radiation power used to develop and improve green sample preparation techniques. This new method is called hydrolytic water phase microextraction assisted by ultrasound (UA-EH-WPME). This solvent-free method is an innovative, environmentally friendly, and straightforward sample preparation process for extracting As from food (rice and flour) samples. The prepared sample has been analyzed by the ICP-MS with LOD up to 27.3 g/kg and RSD of 4.27%, respectively. Shirkhanloo et al. [98] proposed USA-DSL-MPME method was used for the total arsenic (TOA) analysis from water and urine samples. As an extraction phase, bulky amine-functionalized bimodal mesoporous silica nanoparticles (NH2-UVM7) were submerged in ionic liquid (IL). Then, a syringe was used to inject the mixture of NH2-UVM7 and IL/acetone [HMIM][PF6]/AC into 10 mL of the sample with As3+, As5+ TOA, and a pH of 3.5. After ultrasonication and centrifugation, the ILs settled with nanoparticles of NH2-UVM7. The As5+ anion was removed from the centrifuge tube by binding to the amine group As5+ + NH2-UVM7). The total amount of As was found after oxidizing As3+ to As5+ with KMnO4 solution in an acidic medium. ET-AAS was used to quantify the As5+; after that, KOH solutions were used to extract it from the separated phase. Under the best conditions, the linear range (LR), the LOQ, RSD%, and EF for As5+ were 0.02–1.65 g/L, 11 ng/L, 4.3%, and 100.5, respectively. The proposed method worked well to find As3+ and As5+ in water and biological samples such as urine, with recoveries in the 95%–103% range. By using certified reference material in urine, the accuracy of the USA-DSL-MPME method was also confirmed, with recoveries in the 95%–102% range. Chen et al. [80] proposed HF-SPME online coupled with (IP-RP-HPLC- ICP-MS) developed for the As analysis. The sampling frequency was 6.5 h1, with LOD six target As species were found up to 0.017–0.053 g/L, the RSD cAs3+, DMA, AsB, AsC = 0.5 g/L, (cAs(V), MMA = 0.1 g/L, n = 5) ranged between 3.1% and 8.7%, and the EF varied from 4- to 19-fold. To check the analytical reproducibility of the proposed method, reference materials such as DORM-2 (dogfish) and CRM No. 18 (human urine) have been analyzed. The proposed method has been efficiently utilized for the As analysis from human urine, with recoveries ranging from 92.6% to 107% for spiked samples. Ahmad et al. [67] proposed a method for analyzing trace amounts of As using DSPME that uses ultrasound. At a concentration of 100 g/L of arsenic, the cadmium sulfide nanoparticles (CdS NPs) made by hydrothermal synthesis took in both types of arsenic within 20 s. The LOD of the proposed method (3 S/m) was found to be 0.5–0.2 ng/L for As3+ and 0.8–0.2 ng/L for As5+. Analysis of the standard reference material (SRM) (>95% recovery with 5% RSD) showed that the method was correct when it came to systematic and constant errors. Tyburska et al. [97] proposed a hydride generation HS-SPME technique developed to determine total arsenic and selenium. The LOD was found to be up to 0.1 for As and Se, were 0.8 ng/mL 0.1 and 0.8 ng/mL, respectively. The LOD was found up to 0.8 ng/mL for As and 0.1 ng/mL for Se. The developed method determined total As and Se in real-world samples. Zounr et al. [116] developed a green and highly efficient DES-UALPME for the speciation of As3+ and As5+; DDTC was used as a chelating solvent, tetrahydrofuran (THF) was used as a dispersive solvent, choline chloride-phenol was used as an extracting solvent, and ETAAS was used to analyze the concentration of As. The developed method obtained excellent recoveries of As3+ and As5+. The LOD, LOQ, PF, and RSD were calculated as 10 ng/L, 33 ng/L, 25, and 4.3%, respectively. The developed technique’s accuracy was tested using certified reference materials. Chen et al. [100] proposed chip-based magnetic-SPME to analyze As3+ and As5+. A sequential elution strategy was used to separate MMA, DMA, As5+, and As3+so that ICP-MS could be used to measure them online. The lowest amounts found for As5+, DMA, MMA, and As3+ were 4.8, 6.3, 3.8, and 7.1 ng/L. Between 23 and 25 enrichment factors were used, and 7 samples per hour were processed. The online system was used to monitor As species in SCC-7 in cell samples. Ali et al. [102] loaded the polystyrene polydimethylsiloxane into the syringe system’s micropipette tip as an adsorbent to develop SPME. Standard solutions of As3+ and As5+ were passed through the adsorbent loaded in a micropipette tip to test the adsorption behaviors. As3+ was subtracted from the total inorganic concentration to calculate As3+ concentration in water samples. Different factors influencing the determination of the As5+ species, such as adsorbent amount, pH, adsorption capacity, adsorption and desorption study, volume of sample, eluent type, and volume, were also thoroughly investigated. The desired method’s EF and LOD for As5+ were 218 and 6.9 ng/L, respectively. The RSD (n = 10, C = 0.12 g/L) was 4.1%. CRM analysis confirmed the accuracy of the desired technique (Lake Ontario Water TM-28.3 and Riverine Water NRCC-SLRS-4). The desired technique was beneficial for determining the total As3+ and As5+ contents in various natural water samples. Li et al. [101] developed an SPME system with two monolithic capillary columns to separate and preconcentrate inorganic arsenic simultaneously. ICP-MS has been used for the As quantification. The As5+ or As3+ that was kept was then eluted one at a time with diluted HNO3 and put into ICP-MS to be measured. In this work, all factors that affect the retention and elution of As5+ and As3+ were carefully optimized. Using the system, online SPME of a 1-mL sample solution gave a signal enhancement factor of 60 for both As5+ and As3+. The RSD was 3.8% for As5+ and 3.2% for As3+. LODs were 0.005 g/L for both As5+ and As3+. The method was used to analyze the types of As in drinking water and water from the environment, and the results were good. Ashouri et al. [66] developed DLLME using task-specific ionic liquids (TSILs) to extract As. The developed method used an ionic liquid with an ammonium pyrrolidine dithiocarbamate (APDC) bond for chelation with As3+, then KPF6 as an anion-exchange reagent to change the As3+ chelated TSIL into a hydrophobic ionic liquid. Using a 2/1 w/w mixture of KI and Na2S2O3, As5+ was converted to As3+, and the total amount of As was then determined using the ETAAS analysis. To determine As3+ and total As, respectively, linear dynamic ranges of 0.2–15 ng/mL and 0.2–20 ng/mL were noted under ideal conditions. The LOD and LOQ were established to be 0.01 ng/mL and 0.0.034 ng/mL, respectively. The relative standard deviation (RSD%, n = 5) for determining As3+ (10 ng/mL) was 3.2%. Rabieh et al. [72] have devised a new way to microextract As3+ and As5+ species. It uses ionic liquid-based DLLME coupled with EAAS. At a pH of 2, ammonium pyrrolidine dithiocarbamate binds to As3+. 1-butyl-3-methylimidazolium bis(trifluoromethyl sulfonyl) imide pulls the As3+ out of the fine droplets. As5+ stays in the water phase and is turned into As3+. The difference between total inorganic As3+ and As5+ can be used to figure out how much As3+ and As5+. The pH values, the concentration of the chelating reagent, the types and amounts of the extraction and dispersive solvent, and the time of centrifugation were all optimized. The EF of 255, the lowest amount of As3+ found, is 13 ng/L, and the standard deviation for six measurements of 1.0 g/L of As3+ is 4.9%. The method worked well to find As3+ and As5+ in spiked natural water samples, with relative recoveries between 93.3% and 102.1% for As3+ and 94.5% and 101.1% for As5+.
Najafi et al. [117] developed the VA-SSM-SFD bed method for As’s sample preparation. The supramolecular solvents comprised reverse micelles of 1-dodecanol in tetrahydrofuran (THF). These micelles were made by combining micelles of 1-dodecanol in water samples on the spot. Under the best conditions, As5+ formed a complex with heterophony blue, which was directly measured. After As3+ was turned into As5+ by permanganate in an acidic medium, the concentration of As3+ was found by taking away As3+ from the total amount of As. Under ideal conditions, the calibration curve for As determination showed good linearity in the range of 5.0–140.0 g/L (R2 = 0.9988), and the LOD was found to be 0.4 g/L; for 20 g/L, the repeatability and reproducibility were each found to be 2.47% and 3.9%. Wang et al. [118] proposed a new magnetic ionic liquid-based air-assisted liquid–liquid microextraction (MIL–AALLME) method for the selective separation of trace amounts of As3+ and As5+ species in different aqueous samples, soil, and sediment samples before GFAAS analysis. In the MIL–AALLME method, the things that mattered, like pH, amounts of chelating agent, the effect of salt, and types and amounts of MIL, were measured and changed in a planned way. Under the best conditions for extraction, the MIL–AALLME method gave a good linear dynamic range (LDR) of 0.04–10.0 g/L. The LOD and the RSD for seven measurements of 2.0 g/L of As3+ using this method were 0.029 g/L and 2.5%, respectively. The developed method was used to study the different forms of inorganic arsenic in aqueous samples, soil and sediment samples, with good results ranging from 93.0% to 108.5% for the spiked samples. Wang et al. [119] proposed a fully automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction (MAS-LIS-DLLME) for the rapid and efficient separation and preconcentration of trace levels of As3+ species in rice samples. GFAAS have been used for the analysis of As3+. The LOD for As5+ was 0.005 g/L. For seven replicate measurements of 2.0 g/L As5+, the RSD was 3.7%. The developed automated analytical procedure was successfully applied for trace analysis of As species from the rice samples and certified standard reference materials.
Shirani et al. [120] developed a centrifugeless deep eutectic solvent-based magnetic nanofluid-linked air-agitated liquid microextraction (CL-DES-MNF-AALLME). This study proposed a new analytical method that is good for the environment: coupled with ETAAS. This method can simultaneously preconcentrate heavy metals like Pb, As, Cd, and Co. In CL-DES-MNF-AALLME, the extraction solvent is a new magnetic nanofluid made of magnetic multiwall carbon nanotubes based on DES. This nanofluid can be easily separated from the medium without centrifugation. For cadmium, lead, copper, and arsenic, the lowest amounts that could be found were 4.2, 3, 3.5, and 3.6 ng/L, respectively. The proposed extraction method is confirmed by quantitative recoveries with enrichment factor in the range of 635–644.5 and with an RSD of 2.5%–3.1% (n = 7). Asadollahzadeh et al. [121] developed a DSLLME method to extract As3+. ETAAS has been used for the quantification. First, fractional factorial design (FFD) was used in screening experiments to find the variables significantly impacting the extraction process. After that, the important variables were optimized using a central composite design and response surface methodology.
4. Conclusions and future trends
In the past few years, many analytical techniques have been used to preconcentrate arsenic species in environmental and biological samples before analysis. The main goal of previous review articles is to show the two main ways arsenic species can be found: chromatography (HPLC, GC) and spectroscopy (ET-AAS, OES, AFS, ICP-MS). This review mostly talks about preparing samples, including modern methods that do not use solvents like SPME, and ways to use fewer solvents like LPME. Most of the microextraction techniques that use solid adsorbents are used in SPME procedures. Thus, new trends are linked to improvements in this method, which can also be seen in how other element species are determined. When the Analytical Eco-Scale is used to evaluate SPME methods, the scores are higher than those for SPE methods. SPME does not lose points for using solvents, but SPE does, so this technique loses more points. Synthesizing new SPME adsorbents is also not green because it requires different chemicals. However, they are putting the best inventions in this field. Researchers try to minimize the pollution made in analytical labs and make them safer. This is because large-scale production of SPME fibers made electrochemically or by electrospinning can reduce the pollution produced per fiber. Regarding “green” analytical chemistry, online systems with in-tube SPME have the same benefits since only small amounts of solvents are used to desorb analytes. Online SPME systems also have other benefits, such as better accuracy due to automated processes and less need for human labor.
Microextraction methods use very minute amounts of liquids or do not use the liquid, and only a few are used regularly to prepare samples. When LPME techniques are changed, preconcentration is often used using specially designed or chosen extractants, such as ionic liquids or organic solvents with a low melting point, but there are still some fears about how they are used, especially regarding ILs. This makes people look for new solvents, like deep eutectic solvents, which are used instead of ILs in green techniques. Compared to traditional LLE, LPME techniques require less solvent and are easier to use. They also make less waste. On the Analytical Eco-Scale, microvolumes of solvents used for extracting are worth much less than even a thousand times higher volumes of solvents used in LLE.
LPME techniques also have benefits like making it safer and reducing the amount of waste that is made. When combined microextraction techniques are used, high preconcentration factors are possible, but this benefit is tied to introducing more complicated data analysis methods. Complex sample preparation procedures often lead to less accurate results because each step adds a new chance of making mistakes. Also, when SPE is used, combined analytical techniques need more solvents, producing more waste. Therefore, these methods are only helpful when the detection limits are very low. Because of this, combined microextraction techniques are still not used in many studies. Some authors’ new ideas mainly involve tweaking existing methods. As a result, the methods presented are often very similar to those used to extract other analytes. It is also important to note that most papers only look at inorganic arsenic species, such as the difference between As3+ and As5+. Arseno-organic compounds are not often used in research, and chromatographic techniques are usually needed to determine what they are. When new studies show that some of these no-organic species are toxic, there may be more interest in analyzing samples with them. Until that happens, most papers will still be used to determine which types of inorganic arsenic are present.
Acknowledgments
Dr. Muhammad Saqaf Jagirani would like to thank the TUBITAK 2221 Postdoctoral fellowship. This work has been supported by TÜBİTAK-2247/A-National Outstanding Researchers Program (Project No:121C287).
Abbreviations
- AFS
Atomic fluorescence spectrometry
- CE
capillary electrophoresis
- GC
capillary electrophoresis CE, capillary gas chromatography
- DES
deep eutectic solvent
- DLLME
dispersive liquid-liquid microextraction
- EF
enrichment factor
- GC
gas chromatography
- GF-AAS
Graphite furnace atomic absorption spectrometry
- HPLC
high-performance liquid chromatography
- HPLC
high-performance liquid chromatography
- HF-LPME
hollow-fiber liquid phase microextraction
- ICP-MS
inductively coupled plasma-mass spectrometry
- ICP-MS
inductively coupled plasma–mass spectrometry
- ICP-OES
inductively coupled plasma-optical emission spectrometry
- IL
ionic liquid
- LLE
liquid-liquid extraction
- SDME
single-drop microextraction
- SPE
solid phase extraction
- USEPA
United States Environmental Protection Agency
- VA-LPME
vortex-assisted liquid phase microextraction
- WHO
World Health Organization
- USA-DSL-MPME
ultrasound-assisted-dispersive solid-liquid multiple phase microextraction
- HF-SPME
in-tube hollow fiber-solid phase microextraction
- IP-RP-HPLC- ICP-MS
ion-pair reversed-phase high-performance liquid chromatography
- DES-UALPME
deep eutectic solvent ultrasound-assisted liquid phase microextraction
Funding Statement
This work has been supported by TÜBİTAK-2247/A-National Outstanding Researchers Program (Project No:121C287).
References
- 1.Wang Y-F, Lin F, Pang W-Q. Ammonium exchange in aqueous solution using Chinese natural clinoptilolite and modified zeolite. Journal of hazardous materials. 2007;142:160–164. doi: 10.1016/j.jhazmat.2006.07.074. [DOI] [PubMed] [Google Scholar]
- 2.Shakoor MB, Niazi NK, Bibi I, Shahid M, Sharif F, et al. Arsenic removal by natural and chemically modified water melon rind in aqueous solutions and groundwater. Science of the Total Environment. 2018;645:1444–1455. doi: 10.1016/j.scitotenv.2018.07.218. [DOI] [PubMed] [Google Scholar]
- 3.Elci L, Soylak M, Dogan M. Preconcentration of Trace Metals in River Waters by the Application of Chelate Adsorption on Amberlite XAD-4. Fresenius Journal of Analytical Chemistry. 1992;342:175–178. [Google Scholar]
- 4.Hao J, Han M-J, Meng X. Preparation and evaluation of thiol-functionalized activated alumina for arsenite removal from water. Journal of hazardous materials. 2009;167:1215–1221. doi: 10.1016/j.jhazmat.2009.01.124. [DOI] [PubMed] [Google Scholar]
- 5.Sankararamakrishnan N, Mishra NS. A comprehensive review on various analytical methods for the determination of inorganic and organic arsenic in environmental samples. Environmental Contaminants: Measurement, Modelling and Control. 2018:21–41. doi: 10.1007/978-981-10-7332-8_2. [DOI] [Google Scholar]
- 6.Liu Z, Yang Z, Chen S, Liu Y, Sheng L, et al. A smart reaction-based fluorescence probe for ratio detection of hydrazine and its application in living cells. Microchemical Journal. 2020;156:104809. doi: 10.1016/j.microc.2020.104809. [DOI] [Google Scholar]
- 7.Yu YL, Du Z, Chen ML, Wang J-H. A miniature lab-on-valve atomic fluorescence spectrometer integrating a dielectric barrier discharge atomizer demonstrated for arsenic Analysis. Journal of Analytical Atomic Spectrometry. 2008;23:493–499. doi: 10.1039/B718977J. [DOI] [Google Scholar]
- 8.Bingöl M, Yentür G, Er B, Öktem AB. Determination of some heavy metal levels in soft drinks from Turkey using ICP/OES method. Czech Journal of Food Sciences. 2010;28:213–216. doi: 10.17221/158/2008-CJFS. [DOI] [Google Scholar]
- 9.Lasswell HD. Propaganda and mass insecurity. Psychiatry. 1950;13:283–299. doi: 10.1080/00332747.1950.11022781. [DOI] [PubMed] [Google Scholar]
- 10.Yu X, He Q, Li Y, He H, Zhang J. Atomic fluorescence spectrometric detection of methylmercury in seawater at sub ng L– 1 level by UV-induced atomization of gaseous methyl ethylmercury after NaBEt4 derivatization with purge and trap pre-concentration and gas chromatography separation. Spectrochimica Acta Part B: Atomic Spectroscopy. 2019;152:1–5. doi: 10.1016/j.sab.2018.12.003. [DOI] [Google Scholar]
- 11.Sitko R, Janik P, Zawisza B, Talik E, Margui E, et al. Green approach for ultratrace determination of divalent metal ions and arsenic species using total-reflection X-ray fluorescence spectrometry and mercapto-modified graphene oxide nanosheets as a novel adsorbent. Analytical chemistry. 2015;87:3535–3542. doi: 10.1021/acs.analchem.5b00283. [DOI] [PubMed] [Google Scholar]
- 12.Faßbender S, Döring AK, Meermann B. Development of complementary CE-MS methods for speciation analysis of pyrithione-based antifouling agents. Analytical and bioanalytical chemistry. 2019;411:7261–7272. doi: 10.1007/s00216-019-02094-5. [DOI] [PubMed] [Google Scholar]
- 13.Vickers NJ. Animal communication: when I’m calling you, will you answer too? Current biology. 2017;27:R713–R715. doi: 10.1016/j.cub.2017.05.064. [DOI] [PubMed] [Google Scholar]
- 14.Murata R, Shimizu T, Uehara N. Speciation arsenic (III) and arsenic (V) in natural water by graphite furnace AAS after co-precipitation with a copper-pyrrolidine dithiocarbamate complex. Bunseki Kagaku. 2005;54:831–836. doi: 10.1016/j.talanta.2014.06.049. [DOI] [Google Scholar]
- 15.Sajid M, Basheer C, Narasimhan K, Buhmeida A, Al Qahtani M, et al. Persistent and endocrine disrupting organic pollutants: advancements and challenges in Analysis, health concerns and clinical correlates. Nature Environment and Pollution Technology. 2016;15:733. https://neptjournal.com/upload-images/NL-56-58-(58)D-401.pdf . [Google Scholar]
- 16.Ghaedi M, Azad FN, Dashtian K, Hajati S, Goudarzi A, et al. Central composite design and genetic algorithm applied for the optimization of ultrasonic-assisted removal of malachite green by ZnO Nanorod-loaded activated carbon. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2016;167:157–164. doi: 10.1016/j.saa.2016.05.025. DOI: [DOI] [PubMed] [Google Scholar]
- 17.Tuzen M, Parlar K, Soylak M. Enrichment/separation of cadmium (II) and lead (II) in environmental samples by solid phase extraction. Journal of hazardous materials. 2005;121:79–87. doi: 10.1016/j.jhazmat.2005.01.015. DOI: [DOI] [PubMed] [Google Scholar]
- 18.Gałuszka A, Migaszewski Z, Namieśnik J. The 12 principles of green analytical chemistry and the significance nemonic of green analytical practices. TrAC Trends in Analytical Chemistry. 2013;50:78–84. doi: 10.1016/j.trac.2013.04.010. [DOI] [Google Scholar]
- 19.Yan Y, Chen X, Hu S, Bai X. Applications of liquid-phase microextraction techniques in natural product analysis: A review. Journal of chromatography A. 2014;1368:1–17. doi: 10.1016/j.chroma.2014.09.068. [DOI] [PubMed] [Google Scholar]
- 20.Płotka-Wasylka J, Szczepańska N, de La Guardia M, Namieśnik J. Modern trends in solid phase extraction: new sorbent media. TrAC Trends in Analytical Chemistry. 2016;77:23–43. doi: 10.1016/j.trac.2015.10.010. [DOI] [Google Scholar]
- 21.Sajid M. Porous membrane protected micro-solid-phase extraction: A review of features, advancements and applications. Analytica Chimica Acta. 2017;965:36–53. doi: 10.1016/j.aca.2017.02.023. [DOI] [PubMed] [Google Scholar]
- 22.Jagirani MS, Soylak M. Deep eutectic solvents-based adsorbents in environmental analysis. TrAC Trends in Analytical Chemistry. 2022:116762. doi: 10.1016/j.trac.2022.116762. [DOI] [Google Scholar]
- 23.Jagirani MS, Ozalp O, Soylak M. New trend in the extraction of pesticides from the environmental and food samples applying microextraction based green chemistry scenario: a review. Critical Reviews in Analytical Chemistry. 2022;52:1343–1369. doi: 10.1080/10408347.2021.1874867. [DOI] [PubMed] [Google Scholar]
- 24.Mustafai FA, Balouch A, Jalbani N, Bhanger MI, Jagirani MS, et al. Microwave-assisted synthesis of imprinted polymer for selective removal of arsenic from drinking water by applying Taguchi statistical method. European Polymer Journal. 2018;109:133–142. doi: 10.1016/j.eurpolymj.2018.09.041. [DOI] [Google Scholar]
- 25.Armenta S, Garrigues S, de la Guardia M. The role of green extraction techniques in Green Analytical Chemistry. TrAC Trends in Analytical Chemistry. 2015;71:2–8. doi: 10.1016/j.trac.2014.12.011. [DOI] [Google Scholar]
- 26.Anastas P, Eghbali N. Green chemistry: principles and practice. Chemical Society Reviews. 2010;39:301–312. doi: 10.1039/B918763B. [DOI] [PubMed] [Google Scholar]
- 27.Jagirani MS, Uzcan F, Soylak M. A selective and sensitive procedure for magnetic solid-phase microextraction of lead (II) on magnetic cellulose nanoparticles from environmental samples prior to its flame atomic absorption spectrometric detection. Journal of the Iranian Chemical Society. 2021;18:1005–1013. doi: 10.1007/s13738-020-02085-9. [DOI] [Google Scholar]
- 28.Jalili V, Barkhordari A, Baghani AN. The role of microextraction techniques in occupational exposure assessment. A review. Microchemical Journal. 2019;150:104086. doi: 10.1016/j.microc.2019.104086. [DOI] [Google Scholar]
- 29.Yan H, Wang H. Recent development and applications of dispersive liquid–liquid microextraction. Journal of Chromatography A. 2013;1295:1–15. doi: 10.1016/j.chroma.2013.04.053. [DOI] [PubMed] [Google Scholar]
- 30.Jalili V, Barkhordari A, Heidari M. The role of aerogel-based sorbents in microextraction techniques. Microchemical Journal. 2019;147:948–954. doi: 10.1016/j.microc.2019.04.028. [DOI] [Google Scholar]
- 31.Rosado T, Barroso M, Vieira DN, Gallardo E. 4. Paper I-Trends in microextraction approaches for handling human hair extracts-a review. Miniaturized Approaches for Sample Preparation in Hair Testing for Drugs of Abuse and Their Application in Clinical and Forensic Scenarios. 2022:21. doi: 10.1016/j.aca.2021.338792. [DOI] [Google Scholar]
- 32.Jalili V, Barkhordari A, Ghiasvand A. A comprehensive look at solid-phase microextraction technique: A review of reviews. Microchemical Journal. 2020;152:104319. doi: 10.1016/j.microc.2019.104319. [DOI] [Google Scholar]
- 33.Warren J. Needle trap device and solid phase microextraction combined with portable GC-MS for on-site applications. University of Waterloo; 2011. https://uwspace.uwaterloo.ca/bitstream/handle/10012/6014/Warren_Jamie.pdf;sequence=1 . [Google Scholar]
- 34.Rutkowska M, Płotka-Wasylka J, Sajid M, Andruch V. Liquid–phase microextraction: A review of reviews. Microchemical Journal. 2019;149:103989. doi: 10.1016/j.microc.2019.103989. [DOI] [Google Scholar]
- 35.Farajzadeh MA, Asghari A, Feriduni B. An efficient, rapid and microwave-accelerated dispersive liquid–liquid microextraction method for extraction and pre-concentration of some organophosphorus pesticide residues from aqueous samples. Journal of Food Composition and Analysis. 2016;48:73–80. doi: 10.1016/j.jfca.2016.02.007. [DOI] [Google Scholar]
- 36.Tsen WC, Chen PS, Huang SD. Optimization of two different dispersive liquid–liquid microextraction methods followed by gas chromatography–mass spectrometry determination for polycyclic aromatic hydrocarbons (PAHs) analysis in water. Talanta. 2014;120:425–432. doi: 10.1016/j.talanta.2013.11.073. [DOI] [PubMed] [Google Scholar]
- 37.Caldas SS, Rombaldi C, de Oliveira Arias JL, Marube LC, Primel EG. Multi-residue method for determination of 58 pesticides, pharmaceuticals, and personal care products in water using solvent demulsification dispersive liquid–liquid microextraction combined with liquid chromatography-tandem mass spectrometry. Talanta. 2016;146:676–688. doi: 10.1016/j.talanta.2015.06.047. [DOI] [PubMed] [Google Scholar]
- 38.Al-Zahrani I, Basheer C, Htun T. Application of liquid-phase microextraction for the determination of sulfur compounds in crude oil and diesel. Journal of Chromatography A. 2014;1330:97–102. doi: 10.1016/j.chroma.2014.01.015. [DOI] [PubMed] [Google Scholar]
- 39.Shamsipur M, Fattahi N, Assadi Y, Sadeghi M, Sharafi K. Speciation of As (III) and As (V) in water samples by graphite furnace atomic absorption spectrometry after solid phase extraction combined with dispersive liquid–liquid microextraction based on the solidification of floating organic drop. Talanta. 2014;130:26–32. doi: 10.1016/j.talanta.2014.06.049. [DOI] [PubMed] [Google Scholar]
- 40.Elçi L, Divrikli Ü, Soylak M. Inorganic arsenic speciation in various water samples with GFAAS using co-precipitation. International Journal of Environmental and Analytical Chemistry. 2008;88:711–723. doi: 10.1080/03067310802094984. [DOI] [Google Scholar]
- 41.Asadollahi T, Dadfarnia S, Shabani AMH. Separation/pre-concentration and determination of vanadium with dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) and electrothermal atomic absorption spectrometry. Talanta. 2010;82:208–212. doi: 10.1016/j.talanta.2010.04.020. [DOI] [PubMed] [Google Scholar]
- 42.Yiping H, Caiyun W. Ion chromatography for rapid and sensitive determination of fluoride in milk after headspace single-drop microextraction with in situ generation of volatile hydrogen fluoride. Analytica chimica acta. 2010;661:161–166. doi: 10.1016/j.aca.2009.12.018. [DOI] [PubMed] [Google Scholar]
- 43.Meng F-Y, Wei Y-Q, Lu H, Zhou X-T, Liu J-X, et al. Chelatometric dispersive liquid–liquid microextraction followed by capillary electrophoresis for the Analysis of total and water-soluble copper in Rhizoma copies. Chinese Chemical Letters. 2013;24:506–508. doi: 10.1016/j.cclet.2013.03.042. [DOI] [Google Scholar]
- 44.Du J, Yan H, She D, Liu B, Yang G. Simultaneous determination of cypermethrin and permethrin in pear juice by ultrasound-assisted dispersive liquid-liquid microextraction combined with gas chromatography. Talanta. 2010;82:698–703. doi: 10.1016/j.talanta.2010.05.035. [DOI] [PubMed] [Google Scholar]
- 45.Ahmadi-Jouibari T, Fattahi N, Shamsipur M, Pirsaheb M. Dispersive liquid–liquid microextraction followed by high-performance liquid chromatography–ultraviolet detection to the determination of opium alkaloids in human plasma. Journal of pharmaceutical and biomedical Analysis. 2013;85:14–20. doi: 10.1016/j.jpba.2013.06.030. [DOI] [PubMed] [Google Scholar]
- 46.Rasmussen KE, Pedersen-Bjergaard S. Developments in hollow fiber-based, liquid-phase microextraction. TrAC Trends in Analytical Chemistry. 2004;23:1–10. doi: 10.1016/S0165-9936(04)00105-0. [DOI] [Google Scholar]
- 47.Rezaee M, Assadi Y, Hosseini M-RM, Aghaee E, Ahmadi F, et al. Determination of organic compounds in water using dispersive liquid–liquid microextraction. Journal of Chromatography a. 2006;1116:1–9. doi: 10.1016/j.chroma.2006.03.007. [DOI] [PubMed] [Google Scholar]
- 48.Bendicho C, Lavilla I, Pena F, Costas M. Green sample preparation methods. Challenges in green analytical chemistry. 2011;13:63. doi: 10.1016/j.trac.2022.116530. [DOI] [Google Scholar]
- 49.Kailasa SK, Koduru JR, Park TJ, Singhal RK, Wu H-F. Applications of single-drop microextraction in analytical chemistry: A review. Trends in Environmental Analytical Chemistry. 2021;29:e00113. doi: 10.1016/j.teac.2020.e00113. [DOI] [Google Scholar]
- 50.Li G, Row KH. Single-drop microextraction technique for the determination of antibiotics in environmental water. Journal of Separation Science. 2022;45:883–895. doi: 10.1002/jssc.202100682. [DOI] [PubMed] [Google Scholar]
- 51.Wang L, Wang Z, Zhang H, Li X, Zhang H. Ultrasonic nebulization extraction coupled with headspace single drop microextraction and gas chromatography–mass spectrometry for Analysis of the essential oil in Cuminum cyminum L. Analytica chimica acta. 2009;647:72–77. doi: 10.1016/j.aca.2009.05.03. [DOI] [PubMed] [Google Scholar]
- 52.Yang J, Wei H, Teng X, Zhang H, Shi Y. Dynamic ultrasonic nebulization extraction coupled with headspace ionic liquid-based single-drop microextraction for the Analysis of the essential oil in Forsythia suspensa. Phytochem Anal. 2014;25:178–84. doi: 10.1002/pca.2490. [DOI] [PubMed] [Google Scholar]
- 53.Zaruba S, Vishnikin AB, Škrlíková J, Andruch V. Using an Optical Probe as the Microdrop Holder in Headspace Single Drop Microextraction: Determination of Sulfite in Food Samples. Anal Chem. 2016;88:10296–10300. doi: 10.1021/acs.analchem.6b03129. [DOI] [PubMed] [Google Scholar]
- 54.Sajid M. Dispersive liquid-liquid microextraction: Evolution in design, application areas, and green aspects. TrAC Trends in Analytical Chemistry. 2022:116636. doi: 10.1016/j.trac.2022.116636. [DOI] [Google Scholar]
- 55.Ebrahimpour B, Yamini Y, Esrafili A. Emulsification liquid phase microextraction followed by online phase separation coupled to high performance liquid chromatography. Anal Chim Acta. 2012;751:79–85. doi: 10.1016/j.aca.2012.09.014. [DOI] [PubMed] [Google Scholar]
- 56.Wang K, Li N, Lei L, Yang X, Wang Z, et al. Collection and separation of extract in dispersive liquid-liquid microextraction with hollow fiber. Anal Bioanal Chem. 2016;408:3359–67. doi: 10.1007/s00216-016-9410-6. [DOI] [PubMed] [Google Scholar]
- 57.Lopes D, Neves Dias A, Simão V, Carasek E. Determination of emerging contaminants in aqueous matrices with hollow fiber-supported dispersive liquid-liquid microextraction (HF-DLLME) and separation/detection by liquid chromatography – Diode array detection. Microchemical Journal. 2016:130. doi: 10.1016/j.microc.2016.10.011. [DOI] [Google Scholar]
- 58.Olasupo A, Suah FBM. Trends in hollow fibre liquid phase microextraction for the pre-concentration of pharmaceutically active compounds in aqueous solution: A case for polymer inclusion membrane. Journal of Hazardous Materials. 2022:128573. doi: 10.1016/j.jhazmat.2022.128573. [DOI] [PubMed] [Google Scholar]
- 59.Ghambarian M, Yamini Y, Esrafili A, Yazdanfar N, Moradi M. A new concept of hollow fiber liquid–liquid–liquid microextraction compatible with gas chromatography based on two immiscible organic solvents. Journal of Chromatography a. 2010;1217:5652–5658. doi: 10.1016/j.chroma.2010.07.013. [DOI] [PubMed] [Google Scholar]
- 60.Rezazadeh M, Yamini Y, Seidi S, Esrafili A. Pulsed electromembrane extraction: a new concept of electrically enhanced extraction. Journal of Chromatography A. 2012;1262:214–218. doi: 10.1016/j.chroma.2012.08.090. [DOI] [PubMed] [Google Scholar]
- 61.Chamsaz M, Arbab-Zavar MH, Nazari S. Determination of arsenic by electrothermal atomic absorption spectrometry using headspace liquid phase microextraction after in situ hydride generation. Journal of Analytical Atomic Spectrometry. 2003;18:1279–1282. doi: 10.1039/B303169A. [DOI] [Google Scholar]
- 62.Fragueiro S, Lavilla I, Bendicho C. Headspace sequestration of arsine onto a Pd (II)-containing aqueous drop as a pre-concentration method for electrothermal atomic absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy. 2004;59:851–855. doi: 10.1016/j.sab.2004.03.002. [DOI] [Google Scholar]
- 63.Gil SLVM, Bendicho C. Solid sampling in electrothermal atomic absorption spectrometry using commercial atomizers. A review. Spectrochim. Acta Part B. 2009;64:208–214. doi: 10.1039/JA9910600353. [DOI] [Google Scholar]
- 64.Jiang H, Hu B, Chen B, Xia L. Hollow fiber liquid phase microextraction combined with electrothermal atomic absorption spectrometry for the speciation of arsenic (III) and arsenic (V) in fresh waters and human hair extracts. Analytica chimica acta. 2009;634:15–21. doi: 10.1016/j.aca.2008.12.008. [DOI] [PubMed] [Google Scholar]
- 65.López-García I, Rivas RE, Hernández-Córdoba M. Use of carbon nanotubes and electrothermal atomic absorption spectrometry for the speciation of very low amounts of arsenic and antimony in waters. Talanta. 2009;166:355. doi: 10.1016/j.talanta.2011.07.105. [DOI] [PubMed] [Google Scholar]
- 66.Ashouri V, Adib K, Fariman GA, Ganjali MR, Rahimi-Nasrabadi M. Determination of arsenic species using functionalized ionic liquid by in situ dispersive liquid-liquid microextraction followed by atomic absorption spectrometry. Food Chemistry. 2021;349:129115. doi: 10.1016/j.foodchem.2021.129115. [DOI] [PubMed] [Google Scholar]
- 67.Ahmad H, Zhao L, Liu C, Cai C, Ma F. Ultrasound assisted dispersive solid phase microextraction of inorganic arsenic from food and water samples using CdS nanoflowers combined with ICP-OES determination. Food Chemistry. 2021;338:128028. doi: 10.1016/j.foodchem.2020.128028. [DOI] [PubMed] [Google Scholar]
- 68.Baranik A, Gagor A, Queralt I, Marguí E, Sitko R, et al. nanoparticles deposited on graphene nanosheets for adsorption of copper (II) and lead (II) ions and of anionic species of arsenic and selenium. Microchimica Acta. 2018;185:1–9. doi: 10.1007/s00604-018-2806-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Akhtar A, Kazi TG, Afridi HI, Baig JA, Khan M. Simultaneous pre-concentration of toxic elements in eye makeup products through single drop ionic liquid based non-dispersive microextraction method using narrow glass column: Multivariate application. Microchemical Journal. 2020;157:104963. doi: 10.1016/j.microc.2020.104963. [DOI] [Google Scholar]
- 70.Escudero LB, Martinis EM, Olsina RA, Wuilloud RG. Arsenic speciation analysis in mono-varietal wines by online ionic liquid-based dispersive liquid–liquid microextraction. Food chemistry. 2013;138:484–490. doi: 10.1016/j.foodchem.2012.10.054. [DOI] [PubMed] [Google Scholar]
- 71.Grijalba AC, Escudero LB, Wuilloud RG. Capabilities of several phosphonium ionic liquids for arsenic species determination in water by liquid–liquid microextraction and electrothermal atomic absorption spectrometry. Analytical Methods. 2015;7:490–499. doi: 10.1039/C4AY02324B. [DOI] [Google Scholar]
- 72.Rabieh S, Bagheri M, Planer-Friedrich B. Speciation of arsenite and arsenate by electrothermal AAS following ionic liquid dispersive liquid-liquid microextraction. Microchimica Acta. 2013;180:415–421. doi: 10.1007/s00604-013-0946-2. [DOI] [Google Scholar]
- 73.Liu Y, He M, Chen B, Hu B. Simultaneous speciation of inorganic arsenic, selenium and tellurium in environmental water samples by dispersive liquid-liquid microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry. Talanta. 2015;142:213–220. doi: 10.1016/j.talanta.2015.04.050. [DOI] [PubMed] [Google Scholar]
- 74.Pu X, Chen B, Hu B. Solvent bar microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the speciation of inorganic arsenic in water samples. Spectrochimica Acta Part B: Atomic Spectroscopy. 2009;64:679–684. doi: 10.1016/j.sab.2009.06.001. [DOI] [Google Scholar]
- 75.Asadollahzadeh M, Niksirat N, Tavakoli H, Hemmati A, Rahdari P, et al. Application of multi-factorial experimental design to successfully model and optimize inorganic arsenic speciation in environmental water samples by ultrasound assisted emulsification of solidified floating organic drop microextraction. Analytical Methods. 2014;6:2973–2981. doi: 10.1039/C3AY41712C. [DOI] [Google Scholar]
- 76.Kashanaki R, Ebrahimzadeh H, Moradi M. Metal–organic framework based micro solid phase extraction coupled with supramolecular solvent microextraction to determine copper in water and food samples. New Journal of Chemistry. 2018;42:5806–5813. doi: 10.1039/C8NJ00340H. [DOI] [Google Scholar]
- 77.Fiorentini EF, Canizo BV, Wuilloud RG. Determination of As in honey samples by magnetic ionic liquid-based dispersive liquid-liquid microextraction and electrothermal atomic absorption spectrometry. Talanta. 2019;198:146–153. doi: 10.1016/j.talanta.2019.01.091. [DOI] [PubMed] [Google Scholar]
- 78.Liang P, Peng L, Yan P. Speciation of As (III) and As (V) in water samples by dispersive liquid-liquid microextraction separation and determination by graphite furnace atomic absorption spectrometry. Microchimica Acta. 2009;166:47–52. doi: 10.1007/s00604-009-0162-2. [DOI] [Google Scholar]
- 79.Rivas RE, López-García I, Hernández-Córdoba M. Speciation of very low amounts of arsenic and antimony in waters using dispersive liquid–liquid microextraction and electrothermal atomic absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy. 2009;64:329–333. doi: 10.1016/j.sab.2009.03.007. [DOI] [Google Scholar]
- 80.Chen B, Hu B, He M, Mao X, Zu W. Synthesis of mixed coating with multi-functional groups for in-tube hollow fiber solid phase microextraction–high performance liquid chromatography–inductively coupled plasma mass spectrometry speciation of arsenic in human urine. Journal of Chromatography A. 2012;1227:19–28. doi: 10.1016/j.chroma.2011.12.086. [DOI] [PubMed] [Google Scholar]
- 81.Lai G, Chen G, Chen T. Speciation of AsIII and AsV in fruit juices by dispersive liquid–liquid microextraction and hydride generation-atomic fluorescence spectrometry. Food chemistry. 2016;190:158–163. doi: 10.1016/j.foodchem.2015.05.052. [DOI] [PubMed] [Google Scholar]
- 82.Theis AL, Waldack AJ, Hansen SM, Jeannot MA. Headspace solvent microextraction. Analytical chemistry. 2001;73:5651–5654. doi: 10.1021/ac015569c. [DOI] [PubMed] [Google Scholar]
- 83.Xia L, Hu B, Jiang Z, Wu Y, Chen R, Li L. Hollow fiber liquid phase microextraction combined with electrothermal vaporization ICP-MS for the speciation of inorganic selenium in natural waters. Journal of Analytical Atomic Spectrometry. 2006;21:362–365. doi: 10.1039/B514623B. [DOI] [Google Scholar]
- 84.Jagirani MS, Soylak M. A review: Recent advances in solid phase microextraction of toxic pollutants using nanotechnology scenario. Microchemical Journal. 2020;159:105436. doi: 10.1016/j.microc.2020.105436. [DOI] [Google Scholar]
- 85.Kori AH, Jagirani MS, Soylak M. Graphene-Based Nanmaterials: A Sustainable Material for Solid-Phase Microextraction (SPME) for Environmental Applications. Analytical Letters. 2023;56:2385–2400. doi: 10.1080/00032719.2023.2173221. [DOI] [Google Scholar]
- 86.Kori AH, Jakhrani MA, Mahesar SA, Shar GQ, Jagirani MS, et al. Risk assessment of arsenic in groundwater of Larkana city. Geology, Ecology, and Landscapes. 2018;2:8–14. doi: 10.1080/24749508.2018.1438742. [DOI] [Google Scholar]
- 87.Saleh A, Yamini Y, Faraji M, Shariati S, Rezaee M. Hollow fiber liquid phase microextraction followed by high-performance liquid chromatography for determination of ultra-trace levels of Se (IV) after derivatization in urine, plasma and natural water samples. Journal of Chromatography B. 2009;877:1758–1764. doi: 10.1016/j.jchromb.2009.04.039. [DOI] [PubMed] [Google Scholar]
- 88.Zeng C, Wen X, Tan Z, Cai P, Hou X. Hollow fiber supported liquid membrane extraction for ultrasensitive determination of trace lead by portable tungsten coil electrothermal atomic absorption spectrometry. Microchemical Journal. 2010;96:238–242. doi: 10.1016/j.microc.2010.03.008. [DOI] [Google Scholar]
- 89.Xia L, Wu Y, Hu B. Hollow-fiber liquid-phase microextraction prior to low-temperature electrothermal vaporization ICP-MS for trace element analysis in environmental and biological samples. Journal of mass spectrometry. 2007;42:803–810. doi: 10.1002/jms.1216. [DOI] [PubMed] [Google Scholar]
- 90.Li L, Hu B. Hollow-fibre liquid phase microextraction for separation and pre-concentration of vanadium species in natural waters and their determination by electrothermal vaporization-ICP-OES. Talanta. 2007;72:472–479. doi: 10.1016/j.talanta.2006.11.005. [DOI] [PubMed] [Google Scholar]
- 91.Xia L, Hu B, Wu Y. Hollow fiber-based liquid–liquid–liquid microextraction combined with high-performance liquid chromatography for the speciation of organomercury. Journal of Chromatography A. 2007;1173:44–51. doi: 10.1016/j.chroma.2007.09.089. [DOI] [PubMed] [Google Scholar]
- 92.Malevic M, Verheggen F, Martin C. Potential of direct immersion solid-phase microextraction to characterize dissolved volatile organic compounds released by submerged decaying rat cadavers. Forensic Chemistry. 2023;34:100488. doi: 10.1016/j.forc.2023.100488. [DOI] [Google Scholar]
- 93.Thomas CF, Zeh E, Dörfel S, Zhang Y, Hinrichs J. Studying dynamic aroma release by headspace-solid phase microextraction-gas chromatography-ion mobility spectrometry (HS-SPME-GC-IMS): Method optimization, validation, and application. Analytical and Bioanalytical Chemistry. 2021;413:2577–2586. doi: 10.1007/s00216-021-03222-w. [DOI] [PubMed] [Google Scholar]
- 94.Nerín C, Salafranca J, Aznar M, Batlle R. Critical review on recent developments in solventless techniques for extraction of analytes. Analytical and bioanalytical chemistry. 2009;393:809–833. doi: 10.1007/s00216-008-2437-6. [DOI] [PubMed] [Google Scholar]
- 95.Shirani M, Semnani A, Habibollahi S, Haddadi H. Ultrasound-assisted, ionic liquid-linked, dual-magnetic multiwall carbon nanotube microextraction combined with electrothermal atomic absorption spectrometry for simultaneous determination of cadmium and arsenic in food samples. Journal of Analytical Atomic Spectrometry. 2015;30:1057–1063. doi: 10.1039/C4JA00481. [DOI] [Google Scholar]
- 96.Khaligh A, Mousavi HZ, Shirkhanloo H, Rashidi A. Speciation and determination of inorganic arsenic species in water and biological samples by ultrasound assisted-dispersive-micro-solid phase extraction on carboxylated nanoporous graphene coupled with flow injection-hydride generation atomic absorption spectrometry. Rsc Advances. 2015;5:93347–93359. doi: 10.1039/C5RA17229B. [DOI] [Google Scholar]
- 97.Tyburska A, Jankowski K, Rodzik A. Determination of arsenic and selenium by hydride generation and headspace solid-phase microextraction coupled with optical emission spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy. 2011;66:517–521. doi: 10.1016/j.sab.2011.03.010. [DOI] [Google Scholar]
- 98.Shirkhanloo H, Ghazaghi M, Rashidi A, Vahid A. Arsenic speciation based on amine-functionalized bimodal mesoporous silica nanoparticles by ultrasound assisted-dispersive solid-liquid multiple phase microextraction. Microchemical Journal. 2017;130:137–146. doi: 10.1016/j.microc.2016.08.013. [DOI] [Google Scholar]
- 99.Chen S, Wang C, Yan J, Lu D. Use of fibrous TiO2@ graphitic carbon nitride nanocomposites in dispersive micro-solid phase extraction for arsenic species before inductively coupled plasma mass spectrometry determination. Microchemical Journal. 2020;158:105211. doi: 10.1016/j.microc.2020.105211. [DOI] [Google Scholar]
- 100.Chen Z, Chen B, He M, Hu B. Magnetic metal-organic framework composites for dual-column solid-phase microextraction combined with ICP-MS for speciation of trace levels of arsenic. Microchimica Acta. 2020;187:1–9. doi: 10.1007/s00604-019-4055-8. [DOI] [PubMed] [Google Scholar]
- 101.Li P, Zhang XQ, Chen YJ, Lian HZ, Hu X. A sequential solid phase microextraction system coupled with inductively coupled plasma mass spectrometry for speciation of inorganic arsenic. Analytical Methods. 2014;6:4205–4211. doi: 10.1039/C4AY00438H. [DOI] [Google Scholar]
- 102.Ali J, Tuzen M, Kazi TG, Hazer B. Inorganic arsenic speciation in water samples by miniaturized solid phase microextraction using a new polystyrene polydimethyl siloxane polymer in micropipette tip of syringe system. Talanta. 2016;161:450–458. doi: 10.1016/j.talanta.2016.08.075. [DOI] [PubMed] [Google Scholar]
- 103.Tuzen M, Sarı A, Mendil D, Uluozlu OD, Soylak M, et al. Characterization of biosorption process of As (III) on green algae Ulothrix cylindricum. Journal of Hazardous Materials. 2009;165:566–572. doi: 10.1016/j.jhazmat.2008.10.020. [DOI] [PubMed] [Google Scholar]
- 104.Tuzen M, Çıtak D, Mendil D, Soylak M. Arsenic speciation in natural water samples by coprecipitation-hydride generation atomic absorption spectrometry combination. Talanta. 2009;78:52–56. doi: 10.1016/j.talanta.2008.10.03. [DOI] [PubMed] [Google Scholar]
- 105.Tuzen M, Saygi KO, Karaman I, Soylak M. Selective speciation and determination of inorganic arsenic in water, food and biological samples. Food and chemical toxicology. 2010;48:41–46. doi: 10.1016/j.fct.2009.09.012. [DOI] [PubMed] [Google Scholar]
- 106.Jagirani MS, Balouch A, Mahesar SA, Kumar A, Abdullah, et al. Preparation of novel arsenic-imprinted polymer for the selective extraction and enhanced adsorption of toxic As3+ ions from the aqueous environment. Polymer Bulletin. 2020;77:5261–5279. doi: 10.1007/s00289-019-03008-2. [DOI] [Google Scholar]
- 107.Uluozlu OD, Tuzen M, Mendil D, Soylak M. Determination of As (III) and As (V) species in some natural water and food samples by solid-phase extraction on Streptococcus pyogenes immobilized on Sepabeads SP 70 and hydride generation atomic absorption spectrometry. Food and Chemical Toxicology. 2010;48:1393–1398. doi: 10.1016/j.fct.2010.03.007. [DOI] [PubMed] [Google Scholar]
- 108.Balouch A, Jagirani MS, Mustafai FA, Tunio A, Sabir S, et al. Arsenic remediation by synthetic and natural adsorbents. Pakistan Journal of Analytical & Environmental Chemistry. 2017;18:18–36. doi: 10.21743/pjaec/2017.06.02. [DOI] [Google Scholar]
- 109.Bissen M, Frimmel FH. Arsenic—a review. Part I: occurrence, toxicity, speciation, mobility. Acta hydrochemical et hydrobiologica. 2003;31:9–18. doi: 10.1002/aheh.200390025. [DOI] [Google Scholar]
- 110.Braman RS. Foreback CC, Methylated forms of arsenic in the environment. Science. 1973;182:1247–1249. doi: 10.1126/science.182.4118.1247. [DOI] [PubMed] [Google Scholar]
- 111.Altunay N, Elik A, Lanjwani MF, Tuzen M. Assessment of arsenic in water, rice and honey samples using new and green vortex-assisted liquid phase microextraction procedure based on deep eutectic solvent: Multivariate study. Microchemical Journal. 2022;179:107541. doi: 10.1016/j.microc.2022.107541. [DOI] [Google Scholar]
- 112.Haghnazari L, Mirzaei N, Arfaeinia H, Karimyan K, Sharafi H, et al. Speciation of As (III)/As (V) and total inorganic arsenic in biological fluids using new mode of liquid-phase microextraction and electrothermal atomic absorption spectrometry. Biological trace element research. 2018;183:173–181. doi: 10.1007/s12011-017-1118-8. [DOI] [PubMed] [Google Scholar]
- 113.Majumder S, Margui E, Roman-Ross G, Chatterjee D, Hidalgo M. Hollow fiber liquid phase microextraction combined with total reflection X-ray fluorescence spectrometry for the determination of trace level inorganic arsenic species in waters. Talanta. 2020;217:121005. doi: 10.1016/j.talanta.2020.121005. [DOI] [PubMed] [Google Scholar]
- 114.Zeng C, Yan Y, Tang J, Wu Y, Zhong S. Speciation of Arsenic (III) and Arsenic (V) based on Triton X-100 hollow fiber liquid phase microextraction coupled with flame atomic absorption spectrometry. Spectroscopy Letters. 2017;50:220–226. doi: 10.1080/00387010.2017.1305972. [DOI] [Google Scholar]
- 115.Yilmaz E. Use of hydrolytic enzymes as green and effective extraction agents for ultrasound assisted-enzyme based hydrolytic water phase microextraction of arsenic in food samples. Talanta. 2018;189:302–307. doi: 10.1016/j.talanta.2018.07.006. [DOI] [PubMed] [Google Scholar]
- 116.Zounr RA, Tuzen M, Khuhawar MY. Ultrasound assisted deep eutectic solvent based on dispersive liquid liquid microextraction of arsenic speciation in water and environmental samples by electrothermal atomic absorption spectrometry. Journal of molecular liquids. 2017;242:441–446. doi: 10.1016/j.molliq.2017.07.053. [DOI] [Google Scholar]
- 117.Najafi A, Hashemi M. Vortex-assisted supramolecular solvent microextraction based on solidification of floating drop for pre-concentration and speciation of inorganic arsenic species in water samples by molybdenum blue method. Microchemical Journal. 2019;150:104102. doi: 10.1016/j.microc.2019.104102. [DOI] [Google Scholar]
- 118.Wang X, Xu G, Chen P, Liu X, Fang Y, et al. Arsenic speciation analysis in environmental water, sediment and soil samples by magnetic ionic liquid-based air-assisted liquid–liquid microextraction. RSC advances. 2016;6:110247–110254. doi: 10.1039/C6RA21199B. [DOI] [Google Scholar]
- 119.Wang X, Xu G, Chen P, Sun Y, Yao X, et al. Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid–liquid microextraction for the determination of arsenic species in rice samples. RSC Advances. 2018;8:16858–16865. doi: 10.1039/C8RA00875B. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120.Shirani M, Habibollahi S, Akbari A. Centrifuge-less deep eutectic solvent based magnetic nanofluid-linked air-agitated liquid–liquid microextraction coupled with electrothermal atomic absorption spectrometry for simultaneous determination of cadmium, lead, copper, and arsenic in food samples and non-alcoholic beverages. Food chemistry. 2019;281:304–311. doi: 10.1016/j.foodchem.2018.12.110. [DOI] [PubMed] [Google Scholar]
- 121.Asadollahzadeh M, Tavakoli H, Torab-Mostaedi M, Hosseini G, Hemmati A. Response surface methodology based on central composite design as a chemometric tool for optimization of dispersive-solidification liquid–liquid microextraction for speciation of inorganic arsenic in environmental water samples. Talanta. 2014;123:25–31. doi: 10.1016/j.talanta.2013.11.071. [DOI] [PubMed] [Google Scholar]


