Skip to main content
. 2023 Dec 28;15(12):338–349. doi: 10.4329/wjr.v15.i12.338

Table 4.

Inter-reader agreement between the two radiologists

Qualitative assessment
Imaging
κ value (95%CI)
P value
Sharpness of pancreas contour FOCUS-DLR+ 0.73 (0.52–0.95) < 0.0011
FOCUS-DLR- 0.69 (0.45–0.93) < 0.0011
FOCUS-conv 0.66 (0.43–0.89) < 0.0011
Image noise FOCUS-DLR+ 0.69 (0.46–0.92) < 0.0011
FOCUS-DLR- 0.70 (0.50–0.90) < 0.0011
FOCUS-conv 0.64 (0.42–0.87) < 0.0011
Distortion of pancreas FOCUS-DLR+ 0.61 (0.40–0.82) < 0.0011
FOCUS-DLR- 0.71 (0.53–0.89) < 0.0011
FOCUS-conv 0.61 (0.41–0.82) < 0.0011
Visualization of pancreas cystic lesion FOCUS-DLR+ 0.80 (0.56–1.03) < 0.0011
FOCUS-DLR- 0.76 (0.60–0.93) < 0.0011
FOCUS-conv 0.71 (0.51–0.91) < 0.0011
Visualization of MPD on ADC map FOCUS-DLR+ 0.67 (0.51–0.83) < 0.0011
FOCUS-DLR- 0.75 (0.60–0.90) < 0.0011
FOCUS-conv 0.74 (0.54–0.94) < 0.0011
1

A significant difference. P values were obtained by the weighted κ statistic.

κ values: < 0, no agreement; 0–0.20, slight agreement; 0.21–0.40, fair agreement; 0.41–0.60, moderate agreement; 0.61–0.80, substantial agreement; and 0.81–1.00, almost perfect agreement. 95%CI: 95% confidence intervals; DLR: Deep learning-based reconstruction; FOCUS: Field-of-view optimized and constrained undistorted single-shot; FOCUS-conv: Conventional field-of-view optimized and constrained undistorted single-shot; ADC: Apparent diffusion coefficient; MPD: Main pancreatic duct.