Skip to main content
STAR Protocols logoLink to STAR Protocols
. 2023 Dec 19;5(1):102790. doi: 10.1016/j.xpro.2023.102790

Protocol for live-cell super-resolution imaging of transport of pre-ribosomal subunits through the nuclear pore complex

Mark Tingey 1,2,∗, Samuel L Junod 1, Coby Rush 1, Weidong Yang 1,3,∗∗
PMCID: PMC10770744  PMID: 38113144

Summary

Here, we present a protocol for single-molecule super-resolution imaging of the nuclear export of pre-ribosomal subunits pre-40S and pre-60S through nuclear pore complexes. We describe steps for plating cells and co-transfecting cells. We then detail steps for using single-point edge-excitation sub-diffraction microscopy, allowing visualization of real-time dynamics of the pre-ribosomal subunits.

For complete details on the use and execution of this protocol, please refer to Junod et al. (2023).1

Subject areas: Biophysics, Single-molecule Assays, Cell Biology, Cell Membrane, Microscopy

Graphical abstract

graphic file with name fx1.jpg

Highlights

  • •

    Super-resolution imaging of nuclear export of pre-ribosomal subunits in live cells

  • •

    Procedures for cell culture, transfection, and generation of transport buffer

  • •

    Techniques to confirm a complete pre-ribosomal complex during nuclear export

  • •

    Guidelines for interpreting super-resolution images of pre-ribosomal subunits


Publisher’s note: Undertaking any experimental protocol requires adherence to local institutional guidelines for laboratory safety and ethics.


Here, we present a protocol for single-molecule super-resolution imaging of the nuclear export of pre-ribosomal subunits pre-40S and pre-60S through nuclear pore complexes. We describe steps for plating cells and co-transfecting cells. We then detail steps for using single-point edge-excitation sub-diffraction microscopy, allowing visualization of real-time dynamics of the pre-ribosomal subunits.

Before you begin

This protocol makes use of the well-characterized Single-Point Edge-Excitation sub-Diffraction (SPEED) microscopy method to derive 2D localizations in live cells.2 This application deals specifically with evaluating the transport of pre-ribosomal subunits, which are a complex of multiple proteins. To verify that the complex is being tracked rather than individual proteins, a single-molecule FRET (smFRET) labeling approach is employed. To accomplish this imaging approach, this protocol makes use of live HeLa cells. Prior to starting this protocol, researchers must ensure the setup and alignment of a microscope capable of super-resolution, cell culture, and transfection with appropriate proteins. Ensure that the Two-channel simultaneous imaging system DV2 is aligned according to the manufacturer’s specifications.3 It is also important to note that this protocol assumes the dual transfection of a FRET pair, either RpL3-GFP/RpL23-mCherry for pre-60S or RpS13-GFP/RpS11-mCherry for pre-40S, however other FRET pairs may be substituted in and achieve similar results by following this protocol, provided they are excited with the appropriate laser.

Set up the microscope for single-molecule super-resolution SPEED microscopy

Prior to initiating this protocol, it is critical that an appropriate optical setup is aligned and installed. As this protocol provides a methodology for super-resolution imaging with a localization precision of approximately 10 nm, any vibration or optical aberration is consequential. Therefore, ensure that the microscope and laser lines are installed on a research-grade optical table. Further, ensure that laser lines are aligned in such a manner that they pass through the center of the optical objective and strike the center of the detector at a 90° angle.

Mix transport buffer

Inline graphicTiming: 30 min

  • 1.

    In a sterile beaker containing a stir rod, add HEPES, KOAc, NaOAc, MgOAc, and EGTA to 800 mL of distilled water.

  • 2.

    While mixing, correct the pH to 7.3.

  • 3.

    Fill with distilled water to a final volume of 1 L

  • 4.

    Filter contents through a 0.22 μm microfilter.

  • 5.

    Aliquot into 50 mL portions and store at 4°C for no longer than one year.

Transport buffer

Reagent Final concentration Amount
Distilled H2O N/A 1 L
HEPES 20 mM 4.766 g/L
Potassium acetate (KOAc) 110 mM 10.796 g/L
Sodium acetate (NaOAc) 5 mM 0.410 g/L
Magnesium acetate (MgOAc) 2 mM 0.534 g/L
EGTA 1 mM 0.380 g/L

Store at 4°C for no longer than one year.

Mix permeabilization buffer

Inline graphicTiming: 5 min

  • 6.

    Pipette 10 mL of Transport Buffer into a 15 mL conical tube.

  • 7.

    Add 0.3 mg digitonin to the Transport Buffer.

  • 8.

    Gently vortex for 30 s.

  • 9.

    Store at 4° for no longer than one year.

Cell line recovery

Inline graphicTiming: 14 days prior to imaging

  • 10.

    Thaw required cells at least two weeks before transfection experiment. The frozen stocks (−80°C) of cells are thawed at 37°C and resuspended in 1 mL of prewarmed (37°C) DMEM media (DMEM low glucose GlutaMAX Supplement Gibco from Thermo Fisher Scientific, 10% v/v Corning Regular Fetal Bovine Serum, 1% v/v Gibco Penicillin-Streptomycin (10,000 U/mL) from Thermo Fisher Scientific).

  • 11.

    Centrifuge the resuspended cells at 2000 rpms or 402 G for 5 min to remove the DMSO from the freeze-down media (DMEM media, 10% v/v Dimethyl sulfoxide (DMSO) from Alfa Aesar).

  • 12.

    Resuspend the pelleted cells in 1 mL of prewarmed (37°C) DMEM media and transfer into a 25 cm2 culture flask (Corning 25 cm2 vented cell culture flasks) with 4 mL of prewarmed (37°C) DMEM media.

  • 13.

    Incubate the culture flask at 37°C with 5% CO2 for 12–18 h.

  • 14.

    Exchange the culture media in culture flask with fresh DMEM media the next day, and incubate at 37°C with 5% CO2 for 24 h.

  • 15.

    Split the culture cells at least three times over the next two weeks in order to guarantee the cells will be at optimal health for transfection and optimal the imaging experiment. All procedures are finished via aseptic technique. The cell lines used to generate the anticipated data section contain wild-type (WT) HeLa cells and Pom121-GFP stably expressing HeLa cells.

Plating

Inline graphicTiming: 48 h prior to imaging

  • 16.

    Two days prior to the imaging experiments, split and plate cultured cells onto 2–4 glass bottom optical dishes.

  • 17.

    Incubate at 37°C with 5% CO2 for 12–18 h. The cells plated here should be ∼80% confluent in order to achieve optimal transfection results. All procedures are finished via aseptic technique.

Transfection

Inline graphicTiming: 24 h prior to imaging

  • 18.
    According to the protocol from the manufacturer, we transfect cells on glass bottom optical dishes with plasmids encoding the proteins of interest. In our case, using TransIT-LT1 transfection reagent (Mirus). The Opti-MEM reduced serum medium (Thermo Fisher), transfection reagent and plasmids are added dropwise to the glass bottom optical dishes and then mixed by gently flicking for getting homogeneous solution.
    • a.
      When transfecting for FRET pairs of mCherry and GFP that optimal FRET was achieved by using different amounts of mCherry and GFP containing r-proteins.
      • i.
        Transfect with 0.8 μg mCherry containing plasmids Rpl23-mCherry and RpS13-mCherry.
      • ii.
        Transfect with 1.2 μg GFP containing plasmids RpL3-GFP and RpS11-GFP.
    • b.
      The optimal TransIT-LT1 to plasmid DNA ratio was found to be 1 μg DNA to 2 μL transfection reagent.
  • 19.

    Incubate optical dishes in an incubator at 37°C with 5% CO2 for 12–18 h so that fluorescent protein fused to the proteins of interest will have reasonable expression levels during smFRET experiments. All procedures are performed following best aseptic technique.

Note: To evaluate the optimal ratio for transfection or co-transfection, seed a series of plates following the transfection steps 18 and 19 that have different ratios of DNA to transfection reagent. For TransIT-LT1, the manufacturer recommends to test a range from 2-6 μL of reagent per 1 μg of plasmid DNA. After 24 h, using an epifluorescent microscope at 10× magnification, capture three random fields. Count the number of cells expressing the plasmid and divide the number of plasmid expressing cells by the total number of cells in each field. The average of the three fields is taken to generate the transfection, or co-transfection, efficiency. Plot the transfection efficiency for all ratios and identify the point at which the least amount of transfection reagent is used while achieving the highest possible efficiency.

Key resources table

REAGENT or RESOURCE SOURCE IDENTIFIER
Experimental models: Cell lines

HeLa cells stably expressing GFP on the C terminus of POM121 Weidong Yang Lab, Temple University RRID: CVCL_A9H3

Recombinant DNA

Plasmid: rpL3-GFP Junod et al.1 https://doi.org/10.1016/j.isci.2023.107445
Plasmid: rpL23-mCherry Junod et al.1 https://doi.org/10.1016/j.isci.2023.107445
Plasmid: rpS13-GFP Junod et al.1 https://doi.org/10.1016/j.isci.2023.107445
Plasmid: rpS11-mCherry Junod et al.1 https://doi.org/10.1016/j.isci.2023.107445

Software and algorithms

SlideBook 6 3i https://www.intelligent-imaging.com/slidebook
Fiji ImageJ4 ImageJ https://imagej.net/Fiji/Downloads
GDSC SMLM ImageJ plugin5 University of Sussex http://www.sussex.ac.uk/gdsc/intranet/microscopy/UserSupport/AnalysisProtocol/imagej/gdsc_plugins/
OriginPro 2019 OriginLab https://www.originlab.com/2019

Other

Olympus IX81 equipped with 1.4-NA 100× oil immersion apochromatic objective Olympus UPLSAPO 100XO
On-chip multiplication gain charge-coupled device camera Roper Scientific Cascade 128+
Dichroic filter Semrock Di01-R405/488/561/635-25x36
Emission filter Semrock NF01- 405/488/561/635-25X5.0
Two-channel simultaneous imaging system DV2 with DV2-cube-11-Em installed Photometrics DV2-Cube11-Em
565dcxr
D520/30M
D630/50M
506 nm edge BrightLine single-edge standard epi-fluorescence dichroic beamsplitter Semrock FF506-Di03-25x36
593 nm blocking edge BrightLine long-pass filter Semrock FF01-593/LP-25
Two circular variable metallic neutral density filters Newport Cat. No. 50G02AV.1/50Q04AV.2
Top beam steering accessory SM micrometers Newport Cat. No. 670-RCT-M
Bottom steering accessory Newport Cat. No. 670-RCB
Damped optical post, gear rack mounting base 14 in Newport Model 75
Obis solid state 561-nm LS 50 mW laser Coherent, Inc. Laser head 1230935
Laser system 1230936
Obis solid state 488-nm LX 50 mW laser Coherent, Inc. Laser head 1185053
Laser system 1178764
HeNe 632.8-nm 35 mW laser Melles Griot Cat. No. 250LHP-928-249
Pneumatic isolator pre-mounted to research grade optical table Newport Cat. No. RS4000-46-12
Glass bottom culture dishes, 35 mm Petri dish, 14 mm microwell with No. 0 cover glass (0.085–0.13 mm) MatTek Cat. No. P35G-0-14-C
Corning 25 cm2 vented cell culture flasks Corning Cat. No. 430639
Low autofluorescence immersion oil Olympus Cat. No. IMMOIL-F30CC
Dulbecco’s modified Eagle’s medium (DMEM), low glucose GlutaMAX supplement, pyruvate Gibco/ Thermo Fisher Scientific Cat. No. 10567014
Gibco Penicillin-Streptomycin (10,000 U/mL) Gibco/ Thermo Fisher Scientific Cat. No. 15140122
Corning regular fetal bovine serum Corning Cat. No. 35-015-CV
Opti-MEM reduced serum medium Gibco/ Thermo Fisher Scientific Cat. No. 31985088
Trypsin-EDTA (0.25%), phenol red Gibco/ Thermo Fisher Scientific Cat. No. 25200056
TransIT-LT1 transfection reagent Mirus Cat. No. MIR 2300
Gibco 1X phosphate-buffered solution (PBS), pH 7.4 Gibco/ Thermo Fisher Scientific Cat. No. 10010023
Dimethyl sulfoxide (DMSO) Alfa Aesar CAS Number. 67-68-5
Transport buffer This protocol N/A
HEPES Gibco/ Thermo Fisher Scientific Cat. No. 15630130
Potassium acetate (KOAc) Invitrogen/ Thermo Fisher Scientific Cat. No. AM9610
Sodium acetate (NaOAc) Invitrogen/ Thermo Fisher Scientific Cat. No. AM9740
Magnesium acetate (MgOAc) Thermo Scientific Chemicals Cat. No. J60041.AE
EGTA Invitrogen/ Thermo Fisher Scientific Cat. No. E1219

Step-by-step method details

Imaging via SPEED

Inline graphicTiming: 3 h

This step enables researchers to locate and image pre-ribosomal subunits as they pass through the nuclear pore complex of the nucleus of live cells. The end result of this imaging will be 2D localizations with a localization precision of ∼10–20 nm.

  • 1.
    Ensure that the required laser is aligned to precisely strike the center of the detector at a 90° angle.
    • a.
      Place a blank cover slip on the microscope stage. This is done to generate a point spread function, indicating the position of the laser.
    • b.
      At a 10× magnification, adjust the alignment of the 488-nm and 561-nm laser via the micrometer stage so the lasers strike the center of the guides in an overlapping manner.
    • c.
      Increase the magnification to 100×. Further adjust the alignment of the 488-nm and 561-nm laser so they are overlapping in the center of the guides.
    • d.
      Move the focal plane up and down to evaluate the illumination point spread function (iPSF) of the laser. If the laser is striking at 90°, the iPSF should appear to be symmetrical.
      • i.
        If the iPSF is not symmetrical, then gently adjust the mirrors positioned prior to the iris on the laser line until the laser pattern appears symmetrical.
    • e.
      Following alignment, adjust the focus to its smallest point. This should be in the center of the guides, which will be used to indicate where the laser is striking the sample.
      • i.
        When using a 488-nm laser with a 1.4 NA objective, the typical laser power density reaching the focal point is ∼500 kW/ cm2.

Note: For this experiment, an on-chip EMCCD camera (Cascade 128+, Roper Scientific Inc.) was utilized. However, any equivalently sensitive EMCCD camera may be substituted. SlideBook 6.1 has a “guides” feature that may be toggled on and off. These guides indicate the center of the detector, enabling these to function as a landmark to which both lasers will be aligned to. This setup may be modified to accommodate any laser required for your specific fluorophore (Figures 1A and 1B).

  • 2.

    Utilize a 100× oil immersion objective to localize cells under bright field.

  • 3.

    Using epifluorescence illumination, briefly scan samples with both the 488-nm and 561-nm laser.

Note: It is important to ensure that both plasmids are present within the cell you are imaging. You should see clear fluorescence within the nucleolus of the cell for both 488-nm and 561-nm excitation, indicating the presence of the FRET pair on ribosomal subunits within the cell.

Inline graphicCRITICAL: It is of paramount importance that only healthy cells in interphase be imaged. A healthy cell is one that exhibits normal nuclear morphology and is free of nuclear blebbing or other signs of apoptosis (Figures 2A and 2B).

  • 4.

    After identifying a healthy cell containing both plasmids, take a bright-field image as well as an epifluorescence image of both 488-nm and 561-nm.

Note: These images serve to verify the pre-photobleaching presence of both plasmids within the nucleus. The bright-field image is taken to verify the health of the cell that is imaged. Save these images in a folder where the subsequent movies will be stored as a reference.

  • 5.
    Adjust the stage such that the center of the guides is localized to the nuclear envelope at its maximum diameter with either the nucleoplasm or cytoplasm to the left or right side of the guide.
    • a.
      After aligning the guides with the nuclear envelope, take a bright-field image of the membrane.
    • b.
      Save this image as ‘Membrane 1.’

Inline graphicCRITICAL: The bright-field membrane image will be used to compare to a second bright-field membrane image taken at the end of single-molecule imaging and tracking measurements. The transport buffer reduces the movement of the nuclear envelope but does not halt it completely as the cells are not fixed. Therefore, it is important to compare the bright-field membrane images taken before and after imaging to evaluate if the membrane has shifted. If it is found that a membrane has shifted more than 120 nm or ½ pixel, the imaging sequence must be discarded.

  • 6.

    Engage the DualView system by dropping the filter cube into the light path (Figure 1B).

  • 7.
    Using a diffraction-limited illumination point spread function (iPSF), capture an image of the nuclear pore complex (NPC) in the Donor channel.
    • a.
      As the cell line is stably expressing POM121-GFP, the nuclear pore complex can be localized using a 488-nm laser. Set the 488-nm laser power to approximately ∼10 μW and insert the 95% ND filter.
      • i.
        In SlideBook, change the exposure time to 1–10 s and the imaging parameters to camera gain: 3; intensification: 4,000.
      • ii.
        Set the shutter to open while capturing an image and start the capture. If the pixel intensity is oversaturated or too low, decrease or increase the laser power, respectively.
      • iii.
        Name this file ‘Single NPC.’
  • 8.
    Remove the insertable 95% Neutral Density (ND) filter and photobleach the area around the NPC, ensuring no residual fluorescence of POM121-GFP in the illumination area.
    • a.
      Set the 488-nm laser power to 5 mW.
      • i.
        Open the external laser shutter and expose the sample to laser for 30 s or until the region is dark and exhibits no fluorescence while the internal EMCCD shutter is closed, thereby preventing the initialization of a video.
  • 9.
    Capture FRET images of complexes as the FRET pair labeled pre-ribosomal subunits pass through the NPC.
    • a.
      Lower 488 nm laser power to ∼100 μW.
    • b.
      In SlideBook, change the imaging parameters to an exposure time of 2 ms.
    • c.
      Start the video capture, which will automatically open the laser shutter and excite the labeled proteins. Continue the video capture for 30 s. A properly aligned system will capture images where the Donor and Acceptor are centered within their respective channels (Figure 1C).

Inline graphicCRITICAL: Excessively long videos may be subject to a membrane shift of greater than 120 nm or ½ pixel. Researchers should be cognizant of the mobility of the structure being imaged prior to imaging. Employing transport buffer decreases membrane movement and the membrane should exhibit less than several nanometer shift during a 30 s imaging time.

  • 10.
    Capture a bright-field image of the membrane.
    • a.
      Save this image as ‘Membrane 2.’
  • 11.
    Evaluate the membrane for movement during imaging.
    • a.
      Open the images ‘Membrane 1’ and ‘Membrane 2.’
    • b.
      Compare the position of the nuclear envelope.
      • i.
        If more than ½ pixel shift has occurred, discard all imaging data from that cell.
      • ii.
        If less than ½ pixel shift has occurred, save the data and proceed to the next cell.
  • 12.

    Repeat steps 3–9 until a minimum of 10 cells have been imaged. To ensure unbiased results, alternate the illumination position at the equator of the nuclear envelope from cell to cell.

Note: In the event the iPSF becomes misaligned, it is possible that the optical density of the iPSF will be higher on the nuclear or cytoplasmic side. If this were to occur, then the resulting unequal distribution, albeit slight, may impact the results by biasing collection of one region over another. Alternating the collection region on the nuclear envelope ensures that should the iPSF become misaligned such that the illumination area biases the nucleoplasm or cytoplasm, this potential source of error will thus be averaged out through multiple collections in differing locations.

  • 13.
    Upon completion of imaging. Use SlideBook to convert the movie files (.spl) to discrete images (.tif).
    • a.
      Load the movie file in SlideBook and navigate to ‘Image’>’Export’ and click ‘Channel intensities as a 16-bit .tiff file.’ A new dialog box will then open asking for the save location. Uncheck ‘write Log File’, to prevent non-.tiff format files from being written to the destination folder. Make certain to check ‘Separate File for Each plane’ and click ‘OK.’
    • b.
      Perform step 11a for each movie. Save them each in different folders.

Note: When selecting save locations, it is advisable to save the movie images in a separate folder located within a folder containing the nuclear pore image, the cell health, and the plasmid presence images. This helps prevent data loss and confusion.

Figure 1.

Figure 1

A simplified schematic of the optical pathway

(A) A schematic of the excitation lasers used in FRET imaging. The inset depicts the laser passing through the nuclear envelope while the focal plane is at the nuclear equator.

(B) A simplified schematic of the optical pathway of the DualView 2 module. Sample emission fluorescence from donor and acceptor is green and red, respectively.

(C) Exemplar data of a properly aligned DualView with a successful FRET event over 14 ms. Scale bar: 1 µm.

Figure 2.

Figure 2

Exemplar cells to target for imaging

Displayed here are fluorescent (A) and bright-field (B) images of healthy cells imaged with the focal plane at the nuclear equator. Note how the nuclear envelope is intact and the body of the cell is well attached to the optical dish. Also shown here, are fluorescent (C) and bright-field (D) images of unhealthy cells. Note the nuclear morphology of these cells as well as the degradation of the lamellipodia in panel D. Scale bar: 10 µm. Figure adapted from Cell Press.6

Expected outcomes

Upon completion of this protocol, a dataset consisting of single molecule localizations will have been generated that depict the transport of pre-ribosomal complexes through the NPC. By overlapping the NPC Pore image with the transiting particle, a time series of transport can be generated as is shown in Figures 3A and 3E. These raw images are fit with GDSC to provide single-molecule localizations as shown in Figures 3B and 3C. At the individual level, a trace can be evaluated as successful or abortive and subsequently separated into successful or abortive events. The totality of traces for each class can then be overlapped for successful (Figure 3C) and abortive (Figure 3G), respectively. After having designated successful traces as successful and abortive in step 8, the export efficiency can be determined. This is accomplished using the equation ExportEfficiency=SuccessfulEvents(SuccessfulEvents+AbortiveEvents). This value informs as to the relative success of export a target particle.7,8

Figure 3.

Figure 3

Exemplar data generated from this protocol

Shown here are super resolution time points of a pre-60S pre-ribosomal particle as it interacts with the NPC to successfully export (A) or abort export (E). Graphs of the discrete molecule traces observed in the time point images plotted in relation to the centroid of the NPC for both successful export (B) and abortive (F). An overlap of all traces for successful export (C) and abortive (G). A histogram of interaction times fit with a sigmoidal curve for successful export (D) and a logarithmic decay curve for abortive (H). Scale bar: 1 µm. Data republished with permission by Cell Press. Data reproduced with permission from Cell Press.1

Upon overlapping all traces of their discrete subclass, successful and abortive, respectively, the density along the X and Y axis can be plotted to indicate the density of the traces as they interact with the NPC. This information informs as to the region of the NPC where traces have the most interaction.

Lastly, the interaction time between the particle and the NPC can be calculated from this data. The interaction time is defined as the total amount of time the particle interacts with the NPC. This is calculated by taking individual traces and counting the number of frames found within the interaction region of the NPC. When all interaction times for each subclass of trace, successful and abortive, have been determined, a histogram of interaction times is plotted and fit with an appropriate curve. It should be noted that not all types of interaction time plots can be fit with the same type of curve. For example, the interaction times of successful events (Figure 3D) is shown here to be fit with a sigmoidal curve while the abortive events are fit with a logarithmic decay curve (Figure 3H). The type of curve that best fits the data is indicative of the interaction behavior. For example, a sigmoidal curve indicates a two-step process, suggesting that pre-60S likely has discrete steps involved in export such as the recruitment of multiple export factors or a distinct docking event. Together this data provides valuable direct information regarding the transport dynamics of pre-ribosomal subunits.

Quantification and statistical analysis

Inline graphicTiming: 1–2 weeks

The previous step generated raw imaging data of pre-ribosomal subunits transporting through the NPC. To derive sub-diffraction limited information from the raw images, the data must be analyzed by fitting single molecules with Gaussian functions. This is performed using the GDSC plugin found in ImageJ.

  • 1.
    Localize the centroid of the single nuclear pore complex.
    • a.
      Open the file ‘Single NPC’ in ImageJ.
    • b.
      In ImageJ FIJI, select Plugins > GDSC SMLM > Fitting > Peak Fit. A dialogue box will pop up requesting the fitting requirements. The recommended parameters for fitting a single pore are as follows:
      Parameter Setting
      Calibration (nm/px) 240
      Gain (ADU) 76
      Exposure (ms) 1000
      Precision (nm) 20
      Min Width Factor 0.5
      Max Width Factor 3
      Other parameters default
      Note: The above parameters are the requested parameters from GDSC for fitting single molecule localizations. Calibration refers to the physical pixel size of the camera at 100× magnification. Gain (ADU) is the value representing the digital value assigned to a single photon at the specified intensity and gain. In the event a different camera is utilized than that presented in this protocol, please contact the manufacturer of the camera for this value. Exposure is the length of time the camera will collect photons from the excited sample. Precision refers to the threshold at which the GDSC plugin will present data. In this instance, only fittings with a localization precision lower than 20 nm will be presented. The Min and Max Width Factor refer to the starting width of the Gaussian curve that will be fit to the PSF. As a rule of thumb, if the PSF consists of a complex, such as the 8 labeled copies of Pom121 in the NPC, then a larger Max Width Factor will be employed. For a single fluorophore, a lower Max Width Factor of 1.5 should be selected. All other parameters should be left at the default setting.
    • c.
      A dialogue window will pop up with the value for the centroid of the single pore.
    • d.
      Save this value in a csv file named “single pore localization.”
  • 2.
    Separate the Donor and Acceptor channels into discrete stacks.
    • a.
      In ImageJ FIJI, select File > Import > Image Sequence. A new dialogue box will pop up prompting you to specify the location of the folder containing your .tiff images. Select the folder containing single-molecule images corresponding to the single pore image localized in step 1.
    • b.
      Use the rectangle option on primary ImageJ FIJI tool bar to select the left half of the image. This represents the donor channel data.
      Note: It is important to select exactly half of the image. The DualView separates the field of view into two halves, the green (donor) channel on the left and the red (acceptor) channel on the right. To ensure proper localization, be certain that the selected region only encompasses one channel.
    • c.
      With the donor channel selected, select Image > Duplicate. This will create a separate stack containing only the region of interest. Save this stack as “Donor Channel.”
    • d.
      Repeat Step 2b-c for the right half of the image and save this stack as “Acceptor Channel.”
  • 3.
    After separating the channels into two discrete stacks, it is time to localize single molecules.
    • a.
      Select the Donor Channel stack, then Plugins > GDSC SMLM > Fitting > Peak Fit. A dialogue box will pop up requesting parameters. The suggested parameters for fitting single molecules in the Acceptor Channel are as follows:
      Parameter Setting
      Calibration (nm/px) 240
      Gain (ADU) 76
      Exposure (ms) 2
      Precision (nm) 20
      Min Width Factor 0.5
      Max Width Factor 1.5
      Other parameters default
    • b.
      Select apply to all images in stack and then run. ImageJ FIJI will then produce a localization log that details all single molecule localization within the channel. Save this as a .csv with the name “Donor Channel Localizations.”
    • c.
      After saving the fittings, discrete traces in the Donor Channel can be localized by going to Plugins > GDSC SMLM > Calibration > Trace Diffusion. Select the single-molecule fitting dataset corresponding to the Donor Channel Localizations that are still in memory.
      • i.
        A dialog box requesting parameters for measuring the diffusion coefficient will then pop up. Change the minimum trace length to 3 and leave all other settings at default. Run the trace diffusion module.
      • ii.
        Upon completion, a .CSV containing discreet traces has been generated. Save this file as “Donor Channel Traces.”
  • 4.

    After analyzing the single molecule data present in the Donor Channel stack, it is time to evaluate the Acceptor Channel. Select the Acceptor Channel stack of .tiffs and repeat steps 3a-b. Save these files as “Acceptor Chanel Localizations” and “Acceptor Channel Traces” respectively. The recommended parameters for fitting single molecules in the Acceptor channel are as follows:

Parameter Setting
Calibration (nm/px) 240
Gain (ADU) 76
Exposure (ms) 0.4 or 2
Precision (nm) 40
Min Width Factor 0.5
Max Width Factor 1.5
Other parameters default

Note: As fluorescence in the Acceptor channel is dependent upon FRET occurrence, it is likely to emit far fewer photons relative to the Donor channel. As such, the localization precision in the Acceptor channel is likely to be lower than in the Donor channel.

  • 5.
    After localizing single-molecule traces for both the Donor and Acceptor channels, it is time to evaluate the discrete traces for commonality.
    • a.
      Do this by sorting the list of traces in the “Donor Channel Traces” and “Acceptor Channel Traces” files by frame number.
    • b.
      Identify traces that have fluorescence in the same frame in both channels.
    • c.
      Highlight these traces as being representative of successful single-molecule traces of pre-ribosomal subunits.

Note: When plotted in the XY dimension, the two traces should overlap with less than 10 nm of offset between each point.

Inline graphicCRITICAL: To ensure that a complete pre-ribosomal complex has been formed, FRET signal must be present to consider the trace viable. Any localizations in the Donor channel that do not correspond with a localization in the Acceptor channel cannot be treated as a complete pre-ribosomal complex.

  • 6.
    After identifying single-molecule localizations of successful FRET pairs, the data will be zero normalized to the centroid of the NPC. This is accomplished by first converting the localization data of the trace pairs to nm from pixels.
    • a.
      Multiply the localization position in pixels by the size of the camera pixel. In this case, that value is 240 nm. Do this both for the localizations of the FRET pairs as well as the localization of the npc saved in the csv “Single Pore Localization.”
    • b.
      Subtract the X and Y nm localization of the single pore centroid from all FRET localizations to generate a list of zero normalized data.

Note: A slight shift in the acceptor channel may occur when compared to the donor channel. This is a slight alignment issue that has been discussed in Troubleshooting 1. However, it is important to note that FRET pair GFP and mCherry have a maximal range of approximately 10 nm from Donor to Acceptor. Therefore, the presence of fluorescence makes it possible to calculate the offset between Donor and Acceptor Channel.

  • 7.

    Plot the traces of successful single-molecule FRET imaging of pre-ribosomal subunits by opening the graphing software OriginPro. Select the zero normalized XY data. Copy and paste this data into an OriginPro, ensuring an empty row between each discrete trace. From the top toolbar in OriginPro select Plot > Line + Symbol. This will provide an overlay of all single-molecule traces of transport through the NPC.

Inline graphicCRITICAL: Specific subregions can be highlighted when graphing to provide greater insight into the transport of these molecules through the NPC. For instance, a single line at 0 on the X axis represents the midplane of the NPC while a line at -100 is indicative of the most distal region of the nuclear basket, and +100 is indicative of the most distal reach of the cytoplasmic fibrils. This information is used to classify a trace as successful or abortive.

  • 8.
    Separate plotted traces into successful and abortive traces. This is accomplished using individual single molecule traces that have been plotted.
    • a.
      Successful traces are defined as a trace that has an origin in the nucleoplasm, crosses the -100 nm X-dimension line, interacts with the NPC for at least two frames demonstrating confined diffusion and then passes through the NPC, terminating on the cytoplasmic side above +100 nm X-dimension (Figures 4A and 4B).
    • b.
      Abortive traces are defined as a trace that has an origin in the nucleoplasm, crosses the -100 nm X-dimension line, interacts with the NPC for at least two frames demonstrating confined diffusion, then returns to the nucleoplasm (Figures 4C and 4D).
    • c.
      Any trace that fails to complete either of the conditions described in steps 8a and 8b are classified as incomplete and discarded from analysis.

Figure 4.

Figure 4

Examples of export events

(A) A successful export event with an originating point in the nucleoplasm and a termination point in the cytoplasm with an exemplar successful trace (B).

(C) Abortive export event originating in the nucleoplasm, interacting with the NPC for at least two frames, and then return to the nucleoplasm with an exemplar abortive trace (D).

Limitations

This protocol relies upon Förster Resonance Energy Transfer (FRET) to confirm the presence of a full complex. FRET is only viable between two compatible fluorophores that are situated within 10 nm of one another. As such, the FRET pair positioning is paramount to consider during the experimental design phase.

Troubleshooting

Problem 1

When imaging with the DualView module, the displayed image does not clearly show equal, rectangular left and right (donor/acceptor) channels (Steps 6–9).

Potential solution

  • •

    Ensure that while imaging, the filter cube in the DualView system it fully seated in-place; having the cube partially out causes a bypass of the filter set, leading to no separation of donor and acceptor signal. Similarly, ensure that the slider lever is turned fully to “Dual-View Mode” and not “Bypass Mode”.

  • •

    If the image is at an angle and the border between the donor and acceptor channels is not vertical, the DV2 tube can be rotated independently from the C-mount adaptor connected to the camera. Ensure that the ‘Camera lock’ screw found next to the adaptor has been loosened with a 0.05″ Allen tool prior to rotating the DV2 tube. If the camera is stationary, rotate the DV2 tube while holding the C-mount adaptor. If the camera can be rotated, hold the DV2 tube while rotating the C-mount adaptor and camera. Tighten the ‘Camera lock’ screw after adjustment.

  • •

    Overlap or a gap between the channels can be removed by gently adjust the R/L knobs on the DV2 system until the two channels are aligned in the center, vertical, and touching. Further calibration can be accomplished using the calibration grid provided with the system, or with optical beads.

Problem 2

When performing FRET there is weak or absent fluorescence in the acceptor channel (Steps 6–9).

Potential solution

  • •

    Because the Acceptor should be emitting signal due to FRET from the Donor, increasing the excitation laser power of the Donor may be sufficient to see the Acceptor fluorescence. It is important not to increase the power too high as this may photobleach the Donor. In the event of photobleached Donor, neither the Donor nor Acceptor will be observable. It is therefore crucial to consider the photostability of the fluorophores being used, as well as the expected fluorescence based on the Förster distance of the FRET pair, and the filter set(s) in place.

  • •

    To ensure that the Acceptor fluorophore is present, examine the Acceptor with a laser that falls within its excitation spectrum. If signal is observable in the Acceptor channel, the fluorophore is present in the sample.

  • •

    A very weak signal in the Acceptor channel might be due to spectral bleed-through from the Donor fluorophore. It is recommended to utilize spectral data from the fluorophores and filter set(s) to estimate the fluorescent signal level in the Acceptor channel, ensuring it significantly exceeds any bleeding fluorescence. The fluorescence bled into the acceptor channel needs to be corrected in data analysis.

Problem 3

Single particles are not visible or only visible for a short time – obtaining incomplete traces (Steps 6–9, Step 3 of Quantification and statistical analysis).

Potential solution

  • •

    Target fluorophores may be photobleaching too early. To prevent pre-photobleaching of the target particles before they arrive at the nuclear pore complexes, an optical chopper can be used to limit the exposure of the target particle to the excitation laser. It is recommended to keep the ‘on’ time of the chopper at least 10× that of the nuclear export time.

  • •

    Target particles may be out of focus. Insert a lens to convert from single-point to narrow-field illumination and excite the nuclear envelope (NE). Bring the NE into focus then carefully switch back to single-point illumination before imaging.

  • •

    Exposure time may be too long to observe multiple locations of target particles within the nuclear pore complexes. Adjusting the exposure can optimize detection speed, allowing for the capture of export events with a balance between spatial and temporal resolutions. Typically, a 2 ms should suffice for observing pre-ribosomal export events.

  • •

    Transfection parameters may not be optimized. To increase probability of observing successful export events, it is important to determine the optimal conditions for transfection by testing various volumes of lipofectamine and amounts of each plasmid. It is also important to transfect cells at a high confluency.

  • •

    Cells may remain in the transport buffer for an extended period. It is crucial that after the ∼45-min acclimation period, the cells in the transport buffer are imaged within a few minutes to avoid detrimental effects on cell health.

Problem 4

Difficulty localizing single molecules using the GDSC plugin in Fiji (Step 3).

Potential solution

  • •

    Optimization of Gaussian fitting based on acquisition settings and equipment will be necessary for the best results. The initial fitting parameters including the Max Width Factor and the localization precision can be increased incrementally to permit fitting. Begin with the initial width of the Max W and Localization precision settings detailed in step 3 and incrementally increase until fittings are observed. Evaluate the average localization precision of the fittings to ascertain viability.

  • •

    Various methods of background subtraction can be tested prior to fitting. The simplest method is to draw a small ROI in ImageJ in the corner of the image, use the ‘Measure’ or ‘Measure stack’ function to get table of intensity values, and use the average measured value(s) with the ‘Subtract’ function to remove the background. It is necessary to split the image into the Donor and Acceptor channel prior to background removal because they will not have equal background values.

Resource availability

Lead contact

Further information and requests for resources and reagents should be directed to and will be fulfilled by the lead contact, Dr. Weidong Yang, (weidong.yang@temple.edu).

Technical contact

Technical questions on executing this protocol should be directed to and will be answered by the technical contact, Dr. Mark Tingey (mark.tingey@temple.edu).

Materials availability

This protocol uses plasmids generated for the iScience manuscript by Junod et al.1

Data and code availability

This protocol does not require any code or data outside of the key resources table.

Acknowledgments

This work was supported by grants NIGMS 097037, NIGMS 116204, and NIGMS 122552 from the National Institutues of Health, USA, awarded to W.Y.

Author contributions

The manuscript and figures were generated by M.T., S.L.J., and C.R. The manuscript was edited by M.T., S.L.J., C.R., and W.Y.

Declaration of interests

The authors declare no competing interests.

Contributor Information

Mark Tingey, Email: mark.tingey@temple.edu.

Weidong Yang, Email: weidong.yang@temple.edu.

References

  • 1.Junod S.L., Tingey M., Kelich J.M., Goryaynov A., Herbine K., Yang W. Dynamics of Nuclear Export of Pre-ribosomal Subunits Revealed by High-Speed Single-Molecule Microscopy in Live Cells. iScience. 2023;26:107445. doi: 10.1016/j.isci.2023.107445. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Li Y., Tingey M., Ruba A., Yang W. High-speed super-resolution imaging of rotationally symmetric structures using SPEED microscopy and 2D-to-3D transformation. Nat. Protoc. 2021;16:532–560. doi: 10.1038/s41596-020-00440-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Photometrics . Teledyne Photometrics; 2012. Photometrics DV2 Alignment Procedure. DV2 Alignment Procedure. [Google Scholar]
  • 4.Schindelin J., Arganda-Carreras I., Frise E., Kaynig V., Longair M., Pietzsch T., Preibisch S., Rueden C., Saalfeld S., Schmid B., et al. Fiji: an open-source platform for biological-image analysis. Nat. Methods. 2012;9:676–682. doi: 10.1038/nmeth.2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Etheridge T.J., Carr A.M., Herbert A.D. GDSC SMLM: Single-molecule localisation microscopy software for ImageJ. Wellcome Open Res. 2022;7:241. doi: 10.12688/wellcomeopenres.18327.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Tingey M., Li Y., Yang W. Protocol for single-molecule fluorescence recovery after photobleaching microscopy to analyze the dynamics and spatial locations of nuclear transmembrane proteins in live cells. STAR Protoc. 2021;2 doi: 10.1016/j.xpro.2021.100490. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Li Y., Aksenova V., Tingey M., Yu J., Ma P., Arnaoutov A., Chen S., Dasso M., Yang W. Distinct roles of nuclear basket proteins in directing the passage of mRNA through the nuclear pore. Proc. Natl. Acad. Sci. USA. 2021;118 doi: 10.1073/pnas.2015621118. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Ma J., Liu Z., Michelotti N., Pitchiaya S., Veerapaneni R., Androsavich J.R., Walter N.G., Yang W. High-resolution three-dimensional mapping of mRNA export through the nuclear pore. Nat. Commun. 2013;4:2414. doi: 10.1038/ncomms3414. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

This protocol does not require any code or data outside of the key resources table.


Articles from STAR Protocols are provided here courtesy of Elsevier

RESOURCES