Skip to main content
. 2023 Dec 26;9(1):509–519. doi: 10.1021/acsomega.3c06004

Table 4. Remaining Mass of Samples Heated to Different Temperatures (Expressed in Percentage).

adsorbent 200 °C (%) 500 °C (%)
1 # 94.6 41.5
2 # 62.8 44.2
3 # 62.1 42.4
4 # 62.5 47.0
5 # 56.9 42.5
6 # 68.0 50.9
7 # 67.4 51.3
8 # 71.3 53.1