Skip to main content
. 2023 Dec 10;300(1):105554. doi: 10.1016/j.jbc.2023.105554

Table 1.

Targeted LC–MS/MS protocols for detecting and quantifying 10 Ent siderophores and short-length products

Identity Selected ions (m/z)
Retention time (min) References
Q1a Q3b
Ent 668 222 8.47 (21, 46, 51, 86, 90, 91)
lin-Ent 686 222 7.21 (21, 46, 47, 51)
MGE 832 222 6.94 (46, 47, 51)
lin-MGE 848 222 5.89 (46, 47, 51)
DGE 993 222 5.95 (46, 47, 51, 92)
lin-DGE 1010 222 4.98 (21, 46, 47, 51, 92)
(DHBS)2 464 222 5.92 (46, 51, 86, 90, 91)
G1-(DHBS)2 625 222 4.69 (46, 47, 51, 92)
G2-(DHBS)2 787 402 3.64 (46, 47, 51)
DHBS 240 153 2.34 (46, 51, 86, 90, 91)
a

Q1 represents the m/z of the precursor ion selected by the first quadrupole during MS/MS.

b

Q3 represents the m/z of the fragment ion selected by second quadrupole during MS/MS.