Skip to main content
. 2024 Jan 11;10(2):e24226. doi: 10.1016/j.heliyon.2024.e24226

Table 4.

Univariate and multivariate logistic regression analysis for the higher capture threshold in a sensitivity analysis by using QFR as a diagnostic criterion for CAD.

Variables Univariate analysis
Multivariate analysis
OR 95%CI P value Adjusted OR 95%CI P value
CAD (QFR) 4.124 1.993–8.532 <0.001* 4.059 1.893–8.703 <0.001*
Age, yrs 1.016 0.977–1.056 0.417
Male 0.739 0.370–1.473 0.390
AADs 1.819 0.898–3.685 0.096 1.786 0.831–3.840 0.137
Hypertension 1.368 0.683–2.741 0.376
Diabetes 2.605 1.263–5.372 0.010* 2.280 1.044–4.983 0.039*
AF 1.222 0.562–2.655 0.613
AVB 1.237 0.621–2.461 0.546
SSS 1.456 0.719–2.949 0.296
Serum potassium, mEq/L 4.019 1.344–12.016 0.013* 4.120 1.236–13.729 0.021*
Procedure time, min 1.007 0.997–1.017 0.178

AADs: antiarrhythmic drugs; AF: atrial fibrillation; AVB: atrioventricular block; CAD: coronary artery disease; CI: confidence interval; OR: Odds ratios; QFR: quantitative flow ratio; SSS: sick sinus syndrome.

*: P < 0.05.