Skip to main content
. 1998 Apr;66(4):1680–1687. doi: 10.1128/iai.66.4.1680-1687.1998

TABLE 1.

T84 monolayer resistance following 15 h of infection with different-size inocula of EHEC O157:H7 CL56

Inoculum size (CFU) Monolayer resistance (% of control value)a
5 × 102 113 ± 11
5 × 104 94 ± 2
5 × 106 64 ± 3b
5 × 107 45 ± 7b
a

Compared to that of uninfected T84 monolayers (resistance of uninfected T84 monolayers, 2,346 ± 97 Ω · cm2). Values represent means ± SEM (n = 3). 

b

Significantly different from value for uninfected cells at P of <0.05.