Skip to main content
. 2023 Dec 31;11(1):14. doi: 10.3390/jcdd11010014

Table 2.

Procedural characteristics.

Baseline Characteristics Global Study Population
(N = 84)
Vascular access
Radial 78 (92)
Femoral 5 (5)
Cubital 1 (1)
Procedural duration (min) 69 (52–86)
Contrast dose 239.5 (178–280)
Fluoroscopy dose 98 (55–1383)
Fluoroscopy time 17.43 (12–26)
Target lesion ^
Left anterior descending 48 (69) *
Circumflex 11 (16) *
Right coronary artery 11 (16) *
Left main 3 (4) *
Diameter reference 2.82 ± 0.41
Lesion characteristics
Stenosis diameter (%) 60 (52–70)
Length (mm) 20 (14–31)
Number of lesions
1 45 (59) *
2 25 (33) *
3 4 (5) *
Type of lesion °
Calcified 8 (9)
Sequential 7 (8)
Bifurcation 55 (59)
NHPR indexes used
RFR 36 (46.8)
DPR 16 (20.8)
iFR 25 (32.5)
Number of implanted stents 1.17 ± 0.46
0 1 (1)
1 72 (78)
2 12 (13)
3 2 (2)
Stent diameter (mm) 2.93 ± 0.45
Stent length (mm) 27 (19–35)

Values are expressed as means ± standard deviation (SD), medians (interquartile ranges) or n (cumulative %, * valid %). ^ data about target lesion location were available for 73 lesions out of 92. ° data about lesion type were available for 70 lesions out of 92.