Determination of specific capacitance from cyclic voltammetry (CV) at various scan rates for electrodes of samples CFGCN-0, CFGCN-1, CFGCN-2, CFGCN-3, and CFGCN-4.
Scan rate (mV s−1) | Specific capacitance (F g−1) | ||||
---|---|---|---|---|---|
CFGCN-0 | CFGCN-1 | CFGCN-2 | CFGCN-3 | CFGCN-4 | |
5 | 48.8 | 67.6 | 124.8 | 244.0 | 129.0 |
10 | 45.0 | 59.8 | 116.3 | 171.7 | 104 |
25 | 23.5 | 51.9 | 103.8 | 142.0 | 95.7 |
50 | 16.3 | 51.3 | 84.28 | 130.4 | 88.1 |
100 | 12.28 | 38.2 | 78.01 | 90.2 | 75.5 |