TABLE 3.
Entry | Parameters | Example |
---|---|---|
Radiopharmaceutical | 99mTc‐MAA, 90Y, other | 99mTc‐MAA |
Imaging modality | Planar, SPECT/CT, PET/CT, other | Planar |
Reconstruction | If Planar: geometric mean, posterior, anterior, other | Anterior and posterior views |
If SPECT/CT or PET/CT (Software): Iteration, subsets, corrections, full width half maximum (FWHM), other |
SPECT/CT with attenuation correction, collimator detector response correction, empirical scatter correction, no filter with in‐house software. CT was calculated with filtered back projection |
|
Segmentation | Modality: Planar, CT, MRI, CBCT, SPECT/CT, PET/CT | Planar, CT |
Drawn ROIs (Software): Liver, Lungs, other |
|
|
Dosimetry | Method (Software / Deposition Model) |
|
Mass Determination: CT, nominal, phantom | Nominal: 1.03 g/cm3 for soft tissue, 1.03 g/cm3 for liver, 0.26 g/cm3 for lungs | |
Calculated Regions: Liver, lungs, other | Liver |