Published in final edited form as: Pollutants. 2024 Jan 28;4(1):26–41. doi: 10.3390/pollutants4010003

Table 4.

Summary of the intervention conditions used in the mass balance model.

Parameter Units Values Description
λ V 1/h 0.71* Estimated annual infiltration rate. Calculated from blower door ACH50 value
λ D 1/h 0.39 [18] Rate of particle removal by deposition on surfaces
P - 0.82 [50] Particle penetration factor
Q/V 1/h 4.96** Recirculation air flow rate of the HVAC normalized by volume
D - 0.28 average * Duty cycle. Experiment time series calculation discussed in Section 4.1
ε H - 0.30 HVAC filter efficiency for PM2.5. Determined from MERV rating using published methods [48,49]
λ PAC 1/h 0.87** PAC filter efficiency for PM2.5 multiplied by the air flow rate of the portable air cleaner normalized by volume. Determined from manufacturer CADR specifications for portable air cleaner
V m3 456* Volume of the house
Co μg/m3 Experiment time series measurement as shown in Section 4.1. Outside particle concentration
*

Measured from test home;

**

manufacture- reported equipment; specifications.