Skip to main content
. 2023 Aug 11;33(4):991–998. doi: 10.1007/s10068-023-01392-0

Table 4.

Quantification results of GM soybean events using pDNA and gDNA calibrators

Target Calibrator Reference
value (%)
Trueness Accuracy Repeatability
Mean of
measured value
Bias (%) Recovery (%) RSD (%)
SYHT0H2 pDNA 3.0 3.08 2.56 102.56 8.78
1.0 1.03 3.33 103.33 8.99
gDNA 3.0 2.93  − 2.44 97.56 7.18
1.0 1.00 0.33 100.33 6.48
MON87751 pDNA 3.0 2.74  − 8.67 91.33 4.48
1.0 0.89  − 10.67 89.33 5.74
gDNA 3.0 2.83  − 5.67 94.33 0.93
1.0 0.97  − 3.00 97.00 2.73
DAS-44406-6 pDNA 3.0 3.55 18.22 118.22 11.38
1.0 1.18 18.00 118.00 3.69
gDNA 3.0 3.25 8.33 108.33 5.12
1.0 1.16 16.33 116.33 7.99
DAS-81419-2 pDNA 3.0 3.07 2.33 102.33 0.33
1.0 0.88  − 11.67 88.33 2.36
gDNA 3.0 3.11 3.78 103.78 3.83
1.0 0.95  − 4.67 95.33 6.74