Skip to main content
. 2024 Jan 16;16(1):e52363. doi: 10.7759/cureus.52363

Table 1. Characteristics of the interventional photometric equipments.

TF+DSLR: Twin flash + Digital single lens reflex camera; RF+DSLR: Ring flash + Digital single lens reflex camera; SMART: Smartphone camera; IOS: Intraoral scanners.

Group Equipment Calibration
1 TF (Godox MF 12 k2) + DSLR (Canon 1500D with 100 mm macro lens) Shutter speed-1/200, f29, ISO-100, magnification-1:3, white balance-Auto, distance-30 cm
2 RF (Godox ML-150)+ DSLR (Canon 1500D with 100 mm macro lens) Shutter speed-1/200,f29, ISO-100, magnification ratio-1:3, white balance-Auto, distance-30 cm
3 SMART (Iphone 12) f50, ISO-200, flash-Auto, magnification ratio-1:3, white balance-5000 K, distance-15 cm
4 IOS (3 shape Trios) Manufacturer’s recommendations