Table 5.
Comparison of various MPPT Control algorithm.
| Reference | Technique | Tracking speed | Accuracy of tracking | Sensing parameter | Complexity | Efficiency % |
|---|---|---|---|---|---|---|
| [161] | Constant voltage | Slow | Slow | Voltage | Simple | 73 |
| [162] | Adaptive reference voltage (ARV) | Medium | Medium | Current & voltage | Simple | 98 |
| [163] | fractional open-circuit voltage (FOCV) | Slow | Low | Voltage | Simple | 93 |
| [163] | perturb and observe (P & O) | Slow | Medium | Current & voltage | Complex | 98 |
| [164] | Ripple correlation control (RCC) | Fast | High | Current & voltage | Complex | 96 |
| [160] | ANN | Medium | High | Irradiance & temperature | Simple | 98 |
| [165] | FLC | Fast | High | Current & voltage | Medium | 97 |