Skip to main content
. 2024 Feb 10;10(4):e26038. doi: 10.1016/j.heliyon.2024.e26038

Table 5.

TSV, TCV, and thermal environment were comprehensively analyzed.

C1 C2 C3 C4 C5
Occupant TSV mTSV −0.116 0.143 −2.385 −0.443 −0.780
σ TSV 1.138 0.900 1.044 1.249 1.194
TCV mTCV 5.326 4.143 3.769 5.242 5.076
σ TCV 1.250 0.900 0.927 1.289 1.311
Thermal environment Temperature mT 21.9 22.4 21.9 21.9 22.2
σ T 1.808 1.304 1.058 1.825 1.211
RH (Humidity) mH 19.0 20.2 21.4 20.3 19.2
σ H 2.260 2.552 2.416 3.204 2.703
CO2 mCO2 735.5 766.0 779.6 772.7 760.5
σ CO2 102.424 129.014 150.084 136.593 101.854
PMV mPMV −0.4 −0.3 −0.4 −0.3 −0.2
σ PMV 0.415 0.352 0.263 0.426 0.290
PPD mPPD 11.7 9.3 9.1 11.0 8.1
σ PPD 10.562 7.886 5.936 12.327 5.823
Sensitivity δ2T mT 0.285 5.874 4.892 −0.052 0.600
σ T 0.455 8.074 10.967 2.569 4.255
δ2H mH −0.468 −7.278 −0.949 −0.039 −0.440
σ H 3.272 7.204 16.062 1.861 3.375
δ2C mCO2 0.017 −0.217 0.058 0.005 −0.019
σ CO2 0.061 0.310 0.181 0.080 0.428
δ2PMV mPMV 1.546 5.357 10.000 0.016 2.159
σ PMV 2.676 3.845 13.540 2.822 4.482
δ2PPD mPPD −0.049 −3.995 −2.499 0.063 0.298
σ PPD 0.274 5.992 6.210 1.506 2.933
Result Rather insensitive Sensitive Rather sensitive Insensitive Neutral

Note: mTSV: Mean thermal sensation vote, mTCV: Mean thermal sensation vote, my: Mean of y, σy: Standard deviation of y, δ2T: Change in temperature(variance), δ2H: Change in humidity, δ2C: Change in CO2, δ2PMV: Change in PMV, δ2PPD: Change in PPD.