Skip to main content
. 2024 Feb 9;11:1325934. doi: 10.3389/fnut.2024.1325934

Table 8.

Results of discrimination models for pathogenic bacteria species established with characteristic wavelengths extracted by different methods.

Model Method of feature band screening Number of bands Accuracy
Training set Test set External validation set
1D-CNN CARS 42 100.00% 95.24% 100.00%
GA 42 100.00% 97.61% 100.00%
SPA 29 100.00% 92.86% 100.00%
PLS-DA CARS 42 100.00% 100.00% 100.00%
GA 42 100.00% 100.00% 100.00%
SPA 29 100.00% 100.00% 100.00%
SVM CARS 42 100.00% 100.00% 100.00%
GA 42 100.00% 100.00% 100.00%
SPA 29 100.00% 100.00% 100.00%