Abstract
Background
Robotic-assisted systems have gained popularity in total knee arthroplasty (TKA). The purpose of this study was to evaluate operative characteristics and radiographic outcomes of obese patients undergoing robotic-assisted TKA.
Methods
A retrospective review of consecutive cases performed by a single surgeon was performed from January 1, 2016, to January 31, 2022. Adult patients with body mass index ≥35 kg/m2 who underwent primary TKA using a computed tomography–assisted robotic system were compared to patients who underwent primary TKA using conventional instrumentation. Demographics, preoperative and postoperative radiographic measurements, and intraoperative outcomes were compared between cohorts. In total, 119 patients were identified, 60 in the robotic-assisted cohort and 59 in the conventional instrumentation cohort.
Results
Age, body mass index, and estimated blood loss were not significantly different between the cohorts. The robotic-assisted cohort experienced longer tourniquet times (93.3 vs 75.5 minutes, P < .001). Preoperative hip-knee-ankle angle (HKA) was similar between the robotic-assisted and conventional cohorts (8.4° ± 4.9° vs 9.3° ± 5.3°, P = .335). Postoperative HKA was 2.0° ± 1.4° in the robotic-assisted group and 3.1° ± 3.23° in the conventional group (P = .040). The proportion of patients with postoperative HKA > 3° of varus or valgus was 9 of 60 (15.0%) in the robotic-assisted cohort compared to 18 of 59 (30.5%) using conventional instrumentation (P = .043).
Conclusions
Obese patients treated with robotic-assisted TKA had postoperative alignment closer to neutral and fewer postoperative radiographic outliers than patients treated with conventional instrumentation. The results of this study support use of robotic-assisted technologies in TKA, particularly in obese patients.
Keywords: Total knee arthroplasty, Robotic-assisted, Conventional, Obesity, Radiographic outcomes
Introduction
Over 40% of United States adults are obese, which presents unique challenges in the development and treatment of osteoarthritis [[1], [2], [3], [4]]. The increasing national prevalence of obesity coincides with a shift in the demographics of patients requiring total knee arthroplasty (TKA) [5]. Advanced computer navigation and robotic-assisted systems may have utility in TKA including improved component positioning, decreased soft-tissue trauma, and reduced postoperative pain when compared to conventional intramedullary femoral and extramedullary tibial guided approaches [[6], [7], [8], [9], [10], [11], [12], [13], [14], [15]]. However, few studies have compared intraoperative differences between robotic-assisted and conventional systems in obese patients undergoing TKA [[16], [17], [18]].
Elevated body mass index (BMI) has been associated with increased component stress, component malalignment, and postoperative complications, such as aseptic loosening, periprosthetic joint infection, and superficial skin infection, when performing TKA [3,4,19,20]. Intraoperatively, excess adipose tissue can hinder surgical exposure and obscure intraoperative landmarks, thereby increasing the difficulty of obtaining appropriate alignment and component fixation [21,22]. Lastly, increased body mass results in increased stress at the fixation interface, thus increasing the risk of aseptic loosening especially in cases of component malpositioning [3,23].
Considering the difficulties encountered when performing TKA in obese patients, robotic-assisted surgery may prove more beneficial in this patient subset. Therefore, the purpose of this study was to compare preoperative and postoperative radiographic measurements between obese patients who underwent TKA with robotic-assisted or conventional systems, as well as to assess intraoperative outcomes such as duration of tourniquet use (tourniquet time [TT]), total operative time, and estimated blood loss (EBL).
Material and methods
Study design
All primary TKA cases performed from January 1, 2016, to January 31, 2022, by a single fellowship-trained orthopedic surgeon (D.A.O.) were identified. All surgeries were performed through a standard medial parapatellar approach and utilized a posterior stabilized implant. For patients who underwent TKA using conventional instrumentation, a measured resection distal femoral cut was performed 6° from the anatomic axis using an intramedullary sword to approximate a cut perpendicular to the mechanical axis of the femur. For all patients who underwent a TKA using standard instrumentation, the senior surgeon aimed for a neutral tibial cut. For patients who underwent a robotic TKA, the senior surgeon made the femoral and tibial cuts to obtain a neutral mechanical axis on postoperative hip-knee-ankle (HKA) films. The Mako Robotic-Arm Assisted Surgery system (Stryker Corporation, Kalamazoo, MI) was utilized for all robotic procedures. The orthopedic surgeon (D.A.O.) began using the Mako Robotic-Arm Assisted Surgery system in early 2016, whereas the first patient included in this study who underwent TKA with the robotic-assisted system was from April of 2018, after the learning curve and initial adoption of this robotic platform. The conventional instrumentation cohort underwent TKA from approximately 2016 to 2018, whereas the robotic-assisted cohort underwent TKA from approximately 2018 to 2021.
A retrospective chart review was performed to identify patient age, BMI at the time of surgery, and whether the procedure was performed using a computed tomography–assisted robotic system (robotic-assisted). Within this cohort, adult patients with a BMI greater than 35 kg/m2 who underwent primary TKA using a robotic-assisted approach were identified. Adult patients with BMI greater than 35 kg/m2 who underwent primary TKA using a conventional approach were identified as the control. Patients who were aged <18 years, underwent non-primary or non-elective TKA, lacked complete surgical records, or did not receive both preoperative and postoperative full-length radiographs were excluded.
Further retrospective chart review was performed to collect patient demographic information (eg, sex, American Society of Anesthesiologists [ASA] classification), preoperative details (eg, laterality, type of deformity [varus, valgus, neutral], range of motion, indication for TKA), and operative details (eg, date of surgery, TT, total operative time, EBL). TT was defined as the time from tourniquet inflation to tourniquet deflation. Total operative time was defined as the time from initial skin incision to completed skin closure. EBL was estimated per surgeon operative report. The HKA angle was measured on preoperative and postoperative full-length standing radiographs independently by one fellowship-trained orthopedic surgeon (R.M.D.) and one trained reviewer (M.K.R.) (Fig. 1). Varus angles were recorded as positive values, and valgus angles were recorded as negative values. Discordant measurements of >2° were assessed independently by a fellowship-trained orthopedic surgeon (N.D.H.). The 2 values for each measurement were then averaged.
Figure 1.
Preoperative and postoperative full-length anterior posterior radiographs of the same patient demonstrating a preoperative anatomic alignment (hip-knee-ankle angle) of 11° varus, and a postoperative anatomic alignment of 0°, prior to and following right total knee arthroplasty with conventional instrumentation. The left total knee arthroplasty was performed with conventional instrumentation and was also included in the present evaluation.
The primary outcomes of interest were radiographic measurements, including postoperative HKA angle and the number of radiographic outliers within each cohort. Secondary outcomes included operative time, TT, and EBL.
The present study was conducted as approved by the institutional review board (IRB HS-14-00,107).
Statistical analysis
Patient demographics, descriptive variables, and radiographic measurements are presented as means or percentages with standard deviations or ranges where appropriate. For radiographic measurements in which varus angles were recorded as positive values and valgus angles were recorded as negative values, the absolute value of measurements was used for comparative analyses. Normally and non-normally distributed continuous variables were compared using two-sample t-tests or Mann-Whitney U tests, respectively. Categorical variables were compared using chi-square analysis. Statistical analyses were performed using SPSS version 27 (IBM, Armonk, NY) with a significance of P < .05.
Study cohorts
In total, 119 patients were identified of which 60 (50.4%) underwent a robotic-assisted TKA, and 59 (49.6%) underwent TKA via a conventional approach. There were no significant differences in patient age between the robotic-assisted TKA group and the conventional TKA (63.2 vs 63.8 years, P = .651). The average patient BMI was similar between cohorts (39.5 vs 39.3 kg/m2, P = .994) (Table 1).
Table 1.
Mean cohort age, body mass index, and operative details with comparisons between the robotic-assisted and traditional total knee arthroplasty approaches.
| Cohort characteristic | Total cohort, N = 119 |
Robotic-assisted cohort, N = 60 |
Traditional cohort, N = 59 |
P value | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Mean | Standard deviation (STD) | Range | Mean | STD | Range | Mean | STD | Range | ||
| Age (y) | 63.50 | 7.97 | 36-91 | 63.17 | 8.59 | 36-91 | 63.83 | 7.34 | 45-78 | .651 |
| Body mass index (kg/m2) | 39.41 | 3.60 | 35-51 | 39.48 | 3.80 | 35-51 | 39.34 | 3.41 | 35-50 | .994 |
| Operative time (min) | 173.50 | 18.48 | 131-247 | 180.83 | 16.34 | 135-220 | 166.03 | 17.62 | 131-247 | <.001 |
| Tourniquet time (min) | 84.58 | 13.08 | 45-130 | 93.33 | 9.87 | 76-130 | 75.53 | 9.29 | 45-100 | <.001 |
| Estimated blood loss (mL) | 65.55 | 30.36 | 50-250 | 69.58 | 31.59 | 50-200 | 61.44 | 28.74 | 50-250 | .057 |
Bold values indicate statistical significance (P < .05).
Results
Patient characteristics
There was a significant difference in ASA scores between the robotic-assisted group and the conventional group in terms of those assigned with an ASA score of 2 (33.3% vs 52.5%) and an ASA score of 3 (66.7% vs 47.5%, P = .034). No significant differences were found in sex (female: 78.3% vs 72.9%, P = .489), laterality (left: 45.0% vs 50.8%, P = .523), or preoperative deformity (varus: 76.7% vs 81.4%; valgus: 23.3% vs 18.6%, P = .530; Table 2).
Table 2.
Frequency descriptives, including sex, laterality, preoperative deformity, and American Surgical Association (ASA) classification score, with comparisons between the robotic-assisted and traditional approaches.
| Cohort characteristic | Total cohort, N = 119 |
Robotic-assisted cohort, N = 60 |
Traditional cohort, N = 59 |
P value | |||
|---|---|---|---|---|---|---|---|
| N | % | N | % | N | % | ||
| Sex | |||||||
| Male | 29 | 24.37 | 13 | 21.67 | 16 | 27.12 | .489 |
| Female | 90 | 75.63 | 47 | 78.33 | 43 | 72.88 | |
| Laterality | |||||||
| Left | 57 | 47.90 | 27 | 45.00 | 30 | 50.85 | .523 |
| Right | 62 | 52.10 | 33 | 55.00 | 29 | 49.15 | |
| Deformity | |||||||
| Varus | 94 | 78.99 | 46 | 76.67 | 48 | 81.36 | .530 |
| Valgus | 25 | 21.01 | 14 | 23.33 | 11 | 18.64 | |
| ASA | |||||||
| 2 | 51 | 42.86 | 20 | 33.33 | 31 | 52.54 | .034 |
| 3 | 68 | 57.14 | 40 | 66.67 | 28 | 47.46 | |
Bold values indicate statistical significance (P < .05).
Operative characteristics
The robotic-assisted group experienced significantly longer TT than the conventional group (93.3 vs 75.5 minutes, P < .001). Total operative time was also significantly higher for the robotic-assisted group (180.8 vs 166.0 minutes, P < .001). However, there were no statistically significant differences in EBL between the 2 cohorts (69.6 vs 61.4 mL, P = .057) (Table 1).
Radiographic measurements
Neither the robotic-assisted nor the conventional groups differed significantly in preoperative HKA angle (8.4° ± 4.9° vs 9.3° ± 5.3°, P = .335). Patients undergoing robotic-assisted TKA had postoperative HKA angles significantly closer to neutral than patients who underwent a conventional TKA (2.0° ± 1.4° vs 3.1° ± 3.2°, P = .014) (Table 3). In addition, the number of patients with postoperative HKA angles outside 0° ± 3° was found to be significantly lower for patients treated using the robotic-assisted approach than with the conventional approach (9/60 vs 18/59, P = .043) (Fig. 2).
Table 3.
Radiographic descriptives including preoperative and postoperative hip-knee-ankle (HKA) angles with comparisons between the robotic-assisted and traditional approaches.
| Cohort characteristic | Total cohort, N = 119 |
Robotic-assisted cohort, N = 60 |
Traditional cohort, N = 59 |
P value | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Mean | Standard deviation (STD) | Range | Mean | STD | Range | Mean | STD | Range | ||
| Preoperative HKA (°) | 8.89 | 5.06 | 0.5-27 | 8.44 | 4.86 | 0.5-20.5 | 9.34 | 5.26 | 0.5-27 | .335 |
| Postoperative HKA (°) | 2.53 | 2.54 | 0-20 | 1.97 | 1.41 | 0-7.5 | 3.11 | 3.23 | 0-20 | .040 |
| Net change in HKA (°) | 7.78 | 4.46 | 0-22.5 | 7.69 | 4.59 | 0.5-22.5 | 7.87 | 4.37 | 0-20.5 | 0.737 |
| N | % | - | N | % | - | N | % | - | ||
| Quantity with postoperative hip-knee-ankle angle outside 0° ± 3° | 27 | 22.69 | - | 51 | 85.00 | - | 41 | 69.49 | - | .043 |
| Quantity with postoperative hip-knee-ankle angle within 0° ± 3° | 92 | 77.31 | - | 9 | 15.00 | - | 18 | 30.51 | - | |
Bold values indicate statistical significance (P < .05).
Figure 2.
Preoperative vs postoperative hip-knee-ankle (HKA) angle measurements in degrees for robotic and conventional total knee arthroplasty (TKA) cohorts.
Discussion
Here we present the radiographic and intraoperative findings comparing obese patients who underwent TKA using a computed tomography–assisted robotic system to obese patients who underwent TKA using a conventional intramedullary femoral and extramedullary tibial-guided approach. There were similarities in both age and BMI between cohorts. The robotic-assisted cohort had similar EBL but longer TT and increased total operative time than the conventional cohort. Although preoperative HKA angles were similar, patients in the robotic-assisted cohort had postoperative HKA angles significantly closer to neutral anatomic alignment. Compared to the conventional cohort, patients who received robotic-assisted TKA were also less likely to have postoperative HKA angle outliers of >3° varus or valgus HKA angle. Overall, this study demonstrates using robotic-assisted systems may improve component accuracy and reduce coronal alignment outliers within a subset of patients with more challenging intraoperative exposure and anatomic landmark identification.
Utilization of robotic-assisted TKA entails a distinct intraoperative workflow with unique disadvantages. For example, the setup and registration of the robotic system is unique to robotic-assisted TKA, which may increase total surgical time [24]. For example, Tompkins et al. performed a propensity score–matched assessment of 2392 robotic and 2392 manually performed TKAs and found significantly increased procedure time as well as in-room to out-of-room operating time [25]. They reported robotic-assisted TKA required 78 minutes, and manual TKA required 70 minutes (P < .0001), and their room-in and room-out were 139 and 107 minutes, respectively (P < .0001). In the present study, we identified both an increased TT as well as overall operative time in the robotic-assisted cohort. In addition, a study by Pelkowski et al. described 36 patients who underwent both robotic-assisted and manual TKA in a crossover study of staged TKAs [26]. They found TT (73 vs 56 minutes) and operative time (116 vs 93 minutes) were significantly higher among their robotic-assisted procedures than among their manual procedures. The trends reported by Tompkins et al. [25] and Pelkowski et al. [26] resemble those reported in the present study in that robotic-assisted TKAs were significantly longer with respect to both TT and operative time. However, our reported operative times (180.8 vs 166.03 minutes) were higher than those reported by both studies, and our TTs (TT: 93.3 vs 75.5 minutes) were higher than those reported by Pelkowski et al. [26]. These differences are likely explained by the current study’s focus on a specific subset of obese, high-risk, and anatomically challenging patients who likely require additional time for surgical exposure, soft-tissue balancing, and component placement.
Robotic-assisted systems may improve the accuracy and reproducibility of component positioning and overall limb alignment particularly for patients with challenging exposures or complex deformities [6,24,27,28]. Worsened radiographic limb alignment, particularly coronal plane varus or valgus malalignment >3°, has been associated with increased risk of aseptic loosening or radiographic lucencies [[29], [30], [31], [32]]. This may be exacerbated in patients with elevated BMI, as this population experiences higher component shear stress [21,22,33]. Previous studies, such as an early randomized controlled trial from Song et al., showed significantly fewer radiographic outliers (defined as ± ≥3° of mechanical axis alignment) in their robotic-assisted cohort than in conventional TKA (0% vs 24%, P < .001) [8]. Of note, their analysis actively excluded patients with BMI of greater than 40 kg/m2. However, even when optimal alignment is pursued, obese patients may still be at risk for aseptic loosening. For example, in a study of 5088 primary TKAs, Abdel et al. identified a two-fold increased risk of aseptic loosening among obese patients with a BMI greater than 35 kg/m2, even with well-aligned constructs [19]. In addition, Ritter et al. performed an evaluation of 6070 TKAs and identified an increased failure rate in patients with a BMI greater than or equal to 41 kg/m2 than in those with a BMI of 23 to 26 kg/m2 [33]. This effect was exacerbated in patients with varus or valgus postoperatively aligned knees. In a study of 1106 patients, Fehring et al. found a cohort of 35 patients who experienced “catastrophic varus collapse” [34]. The average BMI of this subset was 40.5 kg/m2. Overall, obese patients appear to be less tolerant of postoperative coronal misalignment.
Other studies examined radiographic alignment following robotic-assisted TKA comparing obese patients to non-obese patients. Puah et al. and Shetty et al. independently demonstrated that increased BMI was not associated with worse radiographic alignment outcomes following robotic-assisted TKA [35,36]. Puah et al. determined there was no relationship between a patient’s BMI and their postoperative radiographic measurements in their study of 117 primary, computer-navigated TKAs [35]. Shetty et al. assessed 635 non-obese patients with BMI less than 30 kg/m2 and compared them to 520 obese patients with BMI greater than or equal to 30 kg/m2 [36]. They found no differences in postoperative limb alignment, component alignment, or outlier rates between cohorts. To our knowledge, there is only one published study assessing outcomes comparing a cohort of obese patients with BMI greater than 30 kg/m2 who underwent robotic-assisted vs a cohort of obese patients with BMI greater than 30 kg/m2 who underwent conventional TKA [37]. Kamat et al. [37] found 2 of 64 (3.1%) patients in the robotic-assisted cohort had malalignment >3° from a neutral mechanical axis compared to 16 of 74 (21.6%) in the conventional TKA cohort. In the present study, there were a significantly higher quantity of outliers among obese patients who underwent conventional TKA, which is consistent with that reported by Kamat et al. [37]. This being said, robotic-assisted TKA has not been demonstrated to provide superiority to conventional instrumentation in regard to patient-reported functional outcome scores [8,11,[38], [39], [40], [41]]. Longer-term follow-up, larger sample size, and utilization of validated tools are needed to accurately assess for these outcomes [8,9,42,43]. Notably, a recent publication by Hickey et al. demonstrated that in order to identify the predicted relative reduction in revision rates attributable to robotic-assisted technology, a randomized-controlled trial would require each arm of the comparative study to include between 2500 and 4000 patients and would need to follow up patients for a minimum of 15 years [44]. This lengthy follow-up period and patient recruitment may not be logistically feasible among single-center or even multi-center studies without substantial investment and coordination.
There are several limitations to the present study. First, the cohorts were established based on 2 consecutive cohorts with a minimum BMI threshold, and although there were no differences in age, sex, BMI, laterality, and preoperative deformity between the 2 groups, there were differences in preoperative ASA, with the robotic-assisted group having a higher proportion of ASA 3 patients than the conventional instrumentation group. However, this identified difference would be unlikely to impact our radiographic findings, although we acknowledge that a randomized study design would have accounted for this difference in addition to other potential unobservable confounding factors. In addition, we recognize that utilization of a single-surgeon, single-institution method of evaluation potentially increases susceptibility to individual or institutional biases and limits the applicability of our findings. However, this same methodology also provides unmeasurable consistency and intrapatient reliability. Furthermore, the single-surgeon is a high-volume, fellowship-trained, and highly experienced surgeon, leading to additional credibility of the described findings. To avoid bias, all data collection and radiographic measurements were done without the input of the senior surgeon. Lastly, the primary focus of this evaluation was to assess radiographic outcomes of patients with an increased BMI who underwent robotic-assisted vs conventional-approach TKA. This study did not evaluate long-term outcomes such as implant durability, which remains an area of interest for future research by our study group.
Conclusions
Obese patients treated with robotic-assisted TKA had postoperative alignment closer to neutral and fewer radiographic outliers than patients treated with conventional instrumentation. The results of this study demonstrate that robotic-assisted TKA may more reliably achieve radiographic alignment in obese patients and support the ongoing use of robotic-assisted technologies in TKA, although additional research with longer-term follow-up is necessary.
Conflicts of interest
D.A. Oakes receives royalties from LimaCorporate and is a paid consultant for LimaCorporate; N.D. Heckmann receives royalties from Corin U.S.A; is a paid consultant for Intellijoint Surgical, MicroPort Orthopedics, Corin U.S.A, Zimmer; receives stock or stock options from Intellijoint Surgical; and is a Board member of AAOS, AJRR, and AAHKS; all other authors declare no potential conflicts of interest.
For full disclosure statements refer to https://doi.org/10.1016/j.artd.2024.101320.
CRediT authorship contribution statement
Mary K. Richardson: Writing – review & editing, Writing – original draft, Methodology, Investigation, Formal analysis, Data curation, Conceptualization. Ryan M. DiGiovanni: Writing – review & editing, Writing – original draft, Methodology, Investigation, Formal analysis, Data curation. Brian K. McCrae: Writing – review & editing, Writing – original draft, Methodology, Investigation, Formal analysis. Wesley S. Cooperman: Writing – review & editing, Writing – original draft, Methodology, Investigation, Formal analysis. John Ludington: Writing – original draft, Methodology, Investigation, Formal analysis. Nathanael D. Heckmann: Writing – review & editing, Supervision, Methodology, Investigation, Formal analysis, Conceptualization. Daniel A. Oakes: Writing – review & editing, Supervision, Methodology, Investigation, Formal analysis, Conceptualization.
Appendix A. Supplementary data
References
- 1.Bryan S., Afful J., Carroll M., Te-Ching C., Orlando D., Fink S., et al. Centers for Disease Control and Prevention; 2021. NHSR 158. National health and nutrition examination survey 2017–March 2020 pre-pandemic data files. [DOI] [Google Scholar]
- 2.Zheng H., Chen C. Body mass index and risk of knee osteoarthritis: systematic review and meta-analysis of prospective studies. BMJ Open. 2015;5 doi: 10.1136/bmjopen-2014-007568. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.D’Lima D.D., Fregly B.J., Patil S., Steklov N., Colwell C.W., Jr. Knee joint forces: prediction, measurement, and significance. Proc Inst Mech Eng H. 2012;226:95–102. doi: 10.1177/0954411911433372. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Martin J.R., Jennings J.M., Dennis D.A. Morbid obesity and total knee arthroplasty: a growing problem. J Am Acad Orthop Surg. 2017;25:188–194. doi: 10.5435/JAAOS-D-15-00684. [DOI] [PubMed] [Google Scholar]
- 5.Boyce L., Prasad A., Barrett M., Dawson-Bowling S., Millington S., Hanna S.A., et al. The outcomes of total knee arthroplasty in morbidly obese patients: a systematic review of the literature. Arch Orthop Trauma Surg. 2019;139:553–560. doi: 10.1007/s00402-019-03127-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Nam C.H., Lee S.C., Kim J.-H., Ahn H.S., Baek J.-H. Robot-assisted total knee arthroplasty improves mechanical alignment and accuracy of component positioning compared to the conventional technique. J Exp Orthop. 2022;9:108. doi: 10.1186/s40634-022-00546-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Siebert W., Mai S., Kober R., Heeckt P.F. Technique and first clinical results of robot-assisted total knee replacement. Knee. 2002;9:173–180. doi: 10.1016/s0968-0160(02)00015-7. [DOI] [PubMed] [Google Scholar]
- 8.Song E.-K., Seon J.-K., Yim J.-H., Netravali N.A., Bargar W.L. Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res. 2013;471:118–126. doi: 10.1007/s11999-012-2407-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Yang H.Y., Seon J.K., Shin Y.J., Lim H.A., Song E.K. Robotic total knee arthroplasty with a cruciate-retaining implant: a 10-year follow-up study. Clin Orthop Surg. 2017;9:169–176. doi: 10.4055/cios.2017.9.2.169. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Liow M.H.L., Chin P.L., Tay K.J.D., Chia S.L., Lo N.N., Yeo S.J. Early experiences with robot-assisted total knee arthroplasty using the DigiMatchTM ROBODOC® surgical system. Singapore Med J. 2014;55:529–534. doi: 10.11622/smedj.2014136. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Kayani B., Konan S., Huq S.S., Tahmassebi J., Haddad F.S. Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning. Knee Surg Sports Traumatol Arthrosc. 2019;27:1132–1141. doi: 10.1007/s00167-018-5138-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Sires J.D., Craik J.D., Wilson C.J. Accuracy of bone resection in MAKO total knee robotic-assisted surgery. J Knee Surg. 2021;34:745–748. doi: 10.1055/s-0039-1700570. [DOI] [PubMed] [Google Scholar]
- 13.Bollars P., Boeckxstaens A., Mievis J., Kalaai S., Schotanus M.G.M., Janssen D. Preliminary experience with an image-free handheld robot for total knee arthroplasty: 77 cases compared with a matched control group. Eur J Orthop Surg Traumatol. 2020;30:723–729. doi: 10.1007/s00590-020-02624-3. [DOI] [PubMed] [Google Scholar]
- 14.Noyes F.R., Barber-Westin S. Springer Nature; Berlin, Germany: 2021. Critical rehabilitation for partial and total knee arthroplasty: guidelines and objective testing to allow return to physical function, recreational and sports activities. [Google Scholar]
- 15.Naziri Q., Cusson B.C., Chaudhri M., Shah N.V., Sastry A. Making the transition from traditional to robotic-arm assisted TKA: what to expect? A single-surgeon comparative-analysis of the first-40 consecutive cases. J Orthop. 2019;16:364–368. doi: 10.1016/j.jor.2019.03.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Kayani B., Konan S., Tahmassebi J., Pietrzak J.R.T., Haddad F.S. Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty. Bone Joint J. 2018;100-B:930–937. doi: 10.1302/0301-620x.100b7.bjj-2017-1449.r1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Batailler C., Fernandez A., Swan J., Servien E., Haddad F.S., Catani F., et al. MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2021;29:3585–3598. doi: 10.1007/s00167-020-06283-z. [DOI] [PubMed] [Google Scholar]
- 18.Ali M., Kamson A., Yoo C., Singh I., Ferguson C., Dahl R. Early superior clinical outcomes in robotic-assisted TKA compared to conventional TKA in the same patient: a comparative analysis. J Knee Surg. 2022;36:814–819. doi: 10.1055/s-0042-1743232. [DOI] [PubMed] [Google Scholar]
- 19.Abdel M.P., Bonadurer G.F., 3rd, Jennings M.T., Hanssen A.D. Increased aseptic tibial failures in patients with a BMI ≥35 and well-aligned total knee arthroplasties. J Arthroplasty. 2015;30:2181–2184. doi: 10.1016/j.arth.2015.06.057. [DOI] [PubMed] [Google Scholar]
- 20.Turcotte J., Kelly M., Aja J., King P., MacDonald J. Complication rates and resource utilization after total hip and knee arthroplasty stratified by body mass index. J Orthop. 2021;24:111–120. doi: 10.1016/j.jor.2021.02.024. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Estes C.S., Schmidt K.J., McLemore R., Spangehl M.J., Clarke H.D. Effect of body mass index on limb alignment after total knee arthroplasty. J Arthroplasty. 2013;28:101–105. doi: 10.1016/j.arth.2013.02.038. [DOI] [PubMed] [Google Scholar]
- 22.Lai Y.-H., Cao J., Li Z.-X., Feng W., Xu H., Zhou Z.-K. Effect of body mass index on postoperative mechanical alignment and long-term outcomes after total knee arthroplasty: a retrospective cohort study of 671 knees. Ann Transl Med. 2022;10:829. doi: 10.21037/atm-22-3212. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Rand J.A., Coventry M.B. Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res. 1988:168–173. [PubMed] [Google Scholar]
- 24.Kort N., Stirling P., Pilot P., Müller J.H. Robot-assisted knee arthroplasty improves component positioning and alignment, but results are inconclusive on whether it improves clinical scores or reduces complications and revisions: a systematic overview of meta-analyses. Knee Surg Sports Traumatol Arthrosc. 2022;30:2639–2653. doi: 10.1007/s00167-021-06472-4. [DOI] [PubMed] [Google Scholar]
- 25.Tompkins G.S., Sypher K.S., Li H.-F., Griffin T.M., Duwelius P.J. Robotic versus manual total knee arthroplasty in high volume surgeons: a comparison of cost and quality metrics. J Arthroplasty. 2022;37:S782–S789. doi: 10.1016/j.arth.2021.12.018. [DOI] [PubMed] [Google Scholar]
- 26.Pelkowski J.N., Wilke B.K., Crowe M.M., Sherman C.E., Ortiguera C.J., Ledford C.K. Robotic-assisted versus manual total knee arthroplasty in a crossover cohort: what did patients prefer? Surg Technol Int. 2020;37:336–340. [PubMed] [Google Scholar]
- 27.Moon Y.-W., Ha C.-W., Do K.-H., Kim C.-Y., Han J.-H., Na S.-E., et al. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Comput Aided Surg. 2012;17:86–95. doi: 10.3109/10929088.2012.654408. [DOI] [PubMed] [Google Scholar]
- 28.Laddha M., Gaurav S. Assessment of limb alignment and component placement after all burr robotic-assisted TKA. Indian J Orthop. 2021;55:69–75. doi: 10.1007/s43465-020-00269-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Werner F.W., Ayers D.C., Maletsky L.P., Rullkoetter P.J. The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech. 2005;38:349–355. doi: 10.1016/j.jbiomech.2004.02.024. [DOI] [PubMed] [Google Scholar]
- 30.Suh D.-S., Kang K.-T., Son J., Kwon O.-R., Baek C., Koh Y.-G. Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty: a Finite Element Analysis. Bone Joint Res. 2017;6:623–630. doi: 10.1302/2046-3758.611.BJR-2016-0088.R2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Srivastava A., Lee G.Y., Steklov N., Colwell C.W., Jr., Ezzet K.A., D’Lima D.D. Effect of tibial component varus on wear in total knee arthroplasty. Knee. 2012;19:560–563. doi: 10.1016/j.knee.2011.11.003. [DOI] [PubMed] [Google Scholar]
- 32.Fang D.M., Ritter M.A., Davis K.E. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24:39–43. doi: 10.1016/j.arth.2009.04.034. [DOI] [PubMed] [Google Scholar]
- 33.Ritter M.A., Davis K.E., Meding J.B., Pierson J.L., Berend M.E., Malinzak R.A. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93:1588–1596. doi: 10.2106/JBJS.J.00772. [DOI] [PubMed] [Google Scholar]
- 34.Fehring T.K., Fehring K.A., Anderson L.A., Otero J.E., Springer B.D. Catastrophic varus collapse of the Tibia in obese total knee arthroplasty. J Arthroplasty. 2017;32:1625–1629. doi: 10.1016/j.arth.2016.12.001. [DOI] [PubMed] [Google Scholar]
- 35.Puah K.L., Yeo W., Tan M.H. Clinical and radiographic outcomes of computer-navigated total knee arthroplasty are not adversely affected by body mass index. J Orthop. 2020;19:54–58. doi: 10.1016/j.jor.2019.11.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Shetty G.M., Mullaji A.B., Bhayde S., Lingaraju A.P. No effect of obesity on limb and component alignment after computer-assisted total knee arthroplasty. Knee. 2014;21:862–865. doi: 10.1016/j.knee.2014.04.004. [DOI] [PubMed] [Google Scholar]
- 37.Kamat Y.D., Aurakzai K.M., Adhikari A.R. Total knee replacement in the obese patient: comparing computer assisted and conventional technique. ScientificWorldJournal. 2014;2014 doi: 10.1155/2014/272838. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Kim Y.-H., Yoon S.-H., Park J.-W. Does robotic-assisted TKA result in better outcome scores or long-term survivorship than conventional TKA? A randomized, controlled trial. Clin Orthop Relat Res. 2020;478:266–275. doi: 10.1097/CORR.0000000000000916. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Cobb J., Henckel J., Gomes P., Harris S., Jakopec M., Rodriguez F., et al. Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg Br. 2006;88:188–197. doi: 10.1302/0301-620X.88B2.17220. [DOI] [PubMed] [Google Scholar]
- 40.Marchand R.C., Sodhi N., Khlopas A., Sultan A.A., Harwin S.F., Malkani A.L., et al. Patient satisfaction outcomes after robotic arm-assisted total knee arthroplasty: a short-term evaluation. J Knee Surg. 2017;30:849–853. doi: 10.1055/s-0037-1607450. [DOI] [PubMed] [Google Scholar]
- 41.McCormick B.P., Trent S., Geng X., Lee J.W., Boucher H.R. Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients. J Exp Orthop. 2023;10:76. doi: 10.1186/s40634-023-00634-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Lei K., Liu L., Chen X., Feng Q., Yang L., Guo L. Navigation and robotics improved alignment compared with PSI and conventional instrument, while clinical outcomes were similar in TKA: a network meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2022;30:721–733. doi: 10.1007/s00167-021-06436-8. [DOI] [PubMed] [Google Scholar]
- 43.Liow M.H.L., Goh G.S.-H., Wong M.K., Chin P.L., Tay D.K.-J., Yeo S.-J. Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc. 2017;25:2942–2951. doi: 10.1007/s00167-016-4076-3. [DOI] [PubMed] [Google Scholar]
- 44.Hickey M.D., Anglin C., Masri B., Hodgson A.J. How large a study is needed to detect TKA revision rate reductions attributable to robotic or navigated technologies? A simulation-based power analysis. Clin Orthop Relat Res. 2021;479:2350–2361. doi: 10.1097/CORR.0000000000001909. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.