Table 1.

Radiation dose-volume treatment results

DVH parameter DVH goal Results (mean) Results (range)
Protocol-specified goals
 PTV_Eval V95% ≥ 95% of 38.5 Gy 97% 94%-100%
 Whole breast D38.5 Gy ≤ 35% 12% 1%-22%
 Whole breast D19.25 Gy ≤ 60% 41% 19%-59%
 Contralateral breast Dmax ≤ 1.15 Gy <0.01 Gy <0.01 Gy
 Lung ipsilateral V11.55 Gy ≤ 15% 2% <0.1%-9.3%
 Lung contralateral V1.93 Gy ≤ 15% <0.01 Gy <0.01 Gy
 Heart (right-sided) V1.93 Gy ≤ 5% <0.01% <0.01%-0.03%
 Heart (left-sided) V1.93 Gy ≤ 40% <0.01% <0.01%-0.15%
 Thyroid Dmax ≤ 1.15 Gy <0.01 Gy <0.01 Gy
Additional dose-volume results
Left-sided patients
 Heart Mean 0.03 Gy <0.01-0.19 Gy
 Lung V5 0.04% <0.01%-0.14%
 Lung V20 <0.01% <0.01%-0.04%
Right-sided patients
 Heart Mean 0.01 Gy <0.01-0.15 Gy
 Lung V5 0.03% <0.01%-0.12%
 Lung V20 <0.01% <0.01%-0.05%