Table 2.
Author [Ref] | Patients | TS | CS | Bile Duct Diameter | Freehand | Mean Follow-Up | Stent Obstruction | Early AE | Type of Stent Used |
---|---|---|---|---|---|---|---|---|---|
Year | |||||||||
Kunda et al. [21] | 57 | 98.2% | 96.4% | 17.9 mm | None | 151 d | 9.3% | 7% | Axios and Hot Axios |
2016 | 6 × 8 mm (64.2%) 8 × 8 mm (3.6%) | ||||||||
10 × 10 mm (28.6%) 15 × 10 mm (3.6%) | |||||||||
Jacques et al. [12] | 52 | 88.5% | 100% | 17.2 mm | 94.2% | 157 d | 11.5% | 3.8% | Hot Axios |
2019 | 6 × 8 mm (82.7%) 8 × 8 mm (13.5%) 15 × 10 mm (3.8%) | ||||||||
Tsuchiya et al. [22] * | 19 | 100% | 79% | 17.3 mm | 5.2% | 145 d | 26.3% | 15.8% | Hot Axios |
2018 | 6 × 8 mm (52.7%) 8 × 8 mm (47.3%) | ||||||||
El Chafic et al. [18] | 67 | 95.5% | 100% | 17.6 mm | None | 119 d | 17.5% | 7.5% | Hot Axios |
2019 | 10 × 10 mm (100%) | ||||||||
Jacques et al. [11] | 70 | 98.6% | 98.6% | 17.7 mm | 90% | 153 d | 10% | 0% | Hot Axios |
2020 | 6 × 8 mm (85.7%) 8 × 8 mm (13%) 10 × 10 mm (1.3%) | ||||||||
Fugazza et al. [23] | 256 | 93.3% | 96.2% | 17.3 mm | 94.5% | 151 d | 6.7% | 2.7% | Hot Axios |
2022 | 6 × 8 mm (33.6%) 8 × 8 mm (51.6%) | ||||||||
10 × 10 mm (10.9%) 15 × 10 mm (2.7%) | |||||||||
Nagi Stent (1.2%) | |||||||||
On et al. [20] | 120 | 90.8% | 94.8% | 18.7 mm | 71.4% | 70 d | 8.3% | 8.3% | Hot Axios |
2022 | 6 × 8 mm (38.7%) 8 × 8 mm (57.1%) 10 × 10 mm (4.2%) | ||||||||
Vanella et al. [19] | 93 | 97.9% | 93.4% | - | 98.9% | 138 d | 31.8% | 9.7% | Hot Axios |
2023 | 6 × 8 mm (66.7%) 8 × 8 mm (32.3%) 15 × 10 mm (1%) |
* prospective study.