Skip to main content
. 2024 Feb 19;15(2):49. doi: 10.3390/jfb15020049

Table 1.

Comparison of porosity measurements between HPL hydrogels and aerogels. Porosity measurements obtained through mercury porosimetry for both HPL hydrogels and aerogels, providing quantitative data to support SEM observations (n = 3).

Aerogel Dried Using scCO2 Hydrogel Oven Dried at 37 °C
Total porosity between 4 nm and 360 µm (%) 93.9% ± 2% 7.9% ± 4%