Table 2.2.
Pulse timing parameters for the two stimulations from Zeng et al. [12]. A was a single pulse train repeated every 200 ms for 80 s. B consisted of a short pulse train repeated every 1.6 s, again for a total time of 80 s. This is an example of patterned repetitive TUS.
Duration | Ramp Duration | Ramp Shape | Repetition Interval/Frequency | Notes | |
---|---|---|---|---|---|
| |||||
A Pulse | 20 ms | 0 | rectangular | 200 ms/5 Hz | |
Pulse Train | 80 ms | 0 | rectangular | ||
| |||||
B Pulse | 0.32 ms | 0 | rectangular | 1 ms/1 kHz | |
Pulse Train | 500 ms | 0 | rectangular | 1.6 s/0.625 Hz | |
Pulse Train Repeat | 80 s | 0 | rectangular |