Table 2.3.
Pulse timing parameters from Gaur et al. [13] and Mohammadjavadi et al. [14]. Pulse trains had two levels of repetitions.
| Duration | Ramp Duration | Ramp Shape | Repetition Interval/Frequency | Notes | |
|---|---|---|---|---|---|
|
| |||||
| Pulse | 0.5 ms | 0 | rectangular | 1 ms/1 kHz | |
| Pulse Train | 0.3 s | 0 | rectangular | 1 s/1 Hz | |
| Pulse Train Repeat | 30 s | 0 | rectangular | 60 s/0.017 Hz | TUS and Light+TUS conditions were interleaved with Light Only and No Stimulus conditions |
| Repeat 2 | 40 min | 0 | rectangular | ||