Skip to main content
. 2024 Feb 27;14:4743. doi: 10.1038/s41598-024-55178-3

Table 2.

Comparison of ablation experiments on V-Net.

V-Net IoU (%) DSC (%) SEN (%) PPV (%)
Before augmentation 69 81.5 73.7 90.7
Traditional Method 74.4 84.8 81.3 88.9
Ours 83.9 91.2 88.5 94.1