Table 3.
Experimentally recorded mean values of normalized (with respect to 10 mmHg control case, indicated with superscript ‘0’) pHSP27, pMLCP, pCofilin, pLC20 and G-actin under control conditions used for model fitting
| P (mmHg) | (–) | (–) | (–) | (–) | (–) |
|---|---|---|---|---|---|
| 60 | 2.134 (Moreno-Dominguez et al. 2014 | 1.292 (Johnson et al. 2009) | 1.821 (Moreno-Dominguez et al. 2014) | 1.611 (Johnson et al. 2009) | 0.365 (Moreno-Dominguez et al. 2014) |
| 80 | – | – | – | 2.148 (Moreno-Dominguez et al. 2014 | 0.322 (Moreno-Dominguez et al. 2014) |
| 100 | – | 2.169 (Johnson et al. 2009) | – | 2.078 (Johnson et al. 2009) | – |
| 120 | 2.582 (Moreno-Dominguez et al. 2014) | – | 2.476 (Moreno-Dominguez et al. 2014) | 2.246 (Moreno-Dominguez et al. 2014) | 0.110 (Moreno-Dominguez et al. 2014) |
| 140 | – | 3.272 (El-Yazbi et al. 2010) | – | – | – |