Skip to main content
. 2024 Feb 19;10(4):e26680. doi: 10.1016/j.heliyon.2024.e26680

Table 1.

Conditions of the performance, accelerated stability tests (ASTs) and in situ analyses.

Step Gas Flow (NmL/min)
Temperature (°C) Relative Humidity (%) Gas Pressure (Pa)
Anode Cathode
Activation H2 350 Air 1500 80 100 Ambient (1.01 × 105)
Performance 100 & 50
Electrochemical Impedance Spectroscopy H2 200 N2 1000
Linear Sweep Voltammetry H2 200 N2 1000
AST H2 200 Air 420 90 30
Hydrogen permeation H2 200 N2 1000
Linear Sweep Voltammetry H2 200 N2 1000