Skip to main content
. 2024 Jan 15;38:3. doi: 10.47176/mjiri.38.3

Table 4. Optimal cut-off Point of End Systolic and Diastolic Wall Stress to Predict Heart Failure.

Variable AUC Std. Error P Asymptotic 95% CI Cut off Point Sensitivity Specificity
LB UB
ESWS 0.849 0.09 <0.001 0.754 0.944 88 KPa 70% 80 %
EDWS 0.787 0.005 <0.001 0.680 0.895 13.5 KPa 79% 61%

ESWS: End systolic wall stress; EDWS: End diastolic wall stress; Kpa: Kilopascal; CI: Confidence interval; LB: Lower Bound, UB: Upper Bound.