Skip to main content
. 2024 Feb 20;16(8):10019–10032. doi: 10.1021/acsami.3c15783

Figure 9.

Figure 9

Cycle performances of VRFB single cells with PGF, TGF, and TGF-HEO-750 electrodes: (a) CE, (b) VE, (c) EE, and (d) efficiency values estimated from 100 cycles at 120 mA cm–2 and (e) stability of TGF-HEO-750 for 500 cycles at 120 mA cm–2.