Table 2.

Changes of the angle status and IOP in subjects with PACG after peripheral laser iridotomy combined with iridoplasty.

Characteristics Baseline Final visit p value
ACD (mm) 2.09 ± 0.19 2.15 ± 0.32 0.136
ACV (mm) 78.32 ± 11.49 83.04 ± 11.16 0.011
ACA (mm) 26.86 ± 2.53 28.82 ± 4.64 0.022
IOP (mmHg) 15.48 ± 4.79 13.06 ± 2.21 0.001
WTW N-T (mm) 11.48 ± 0.32 11.43 ± 0.34 0.089
Pachy central (μm) 559.03 ± 35.87 554.50 ± 38.61 0.072
Pachy middle (μm) 609.23 ± 35.11 603.77 ± 40.66 0.117
Pachy peripheral (μm) 685.65 ± 48.64 687.13 ± 79.19 0.262

Note. Values represent the mean ± mean deviation. PACG, primary angle-closure glaucoma; ACD, anterior chamber depth (from corneal endothelium to anterior lens surface); ACV, anterior chamber volume; ACA, mean anterior chamber angle; IOP, intraocular pressure; WTW N-T, white to white from nasal to temporal limbus; Pachy mean pachymetry from central (0.0–4.0 mm), middle (4.0–7.0 mm), and peripheral zone (7.0–10.0 mm). Wilcoxon signed-rank test; bold font indicates significant p values (p < 0.05).