Maximum stress of calcaneus, screws and plates during fixation of calcaneal fractures with ORIF and PMIF (MPa)

Von Mises stress (MPa) ORIF PMIF
Type II Type III Type II Type III
Calcaneus 75.85 80.54 59.66 70.02
Screw 200.56 211.59 129.61 209.46