Table 2.

Fitted parameters to 298–333 K sorption and desorption isotherms with 95% confidence t-intervals.

Parameters Fit k and n (kinetic model) Fit ϕ (max displacement model)
b(T=298K) 2.68±0.66 2.68±0.65
ω(T=298K) 0.375±0.067 0.375±0.067
LT=298K,ceq=0/gwgp-1 0.0213±0.0030 0.0213±0.0030
γ/gwgp-1 0.68±0.15 0.68±0.14
k/s-1 1.6×1023±4.8×1024
n 13.2±5.9
ΔHb/kJmol-1 -14.2±1.9 -14.2±1.9
ΔHω/kJmol-1 -1.5±1.2 -1.5±1.2
ϕ/gwgp-1 0.0047±0.0011

k is given in units of inverse time assuming that L and L in Eq. (8) are rigorously normalized by the unit reference concentration 1 gwgp-1.

Pure liquid water reference state (or reference pressure of Po=Psat). Subtract the heat of condensation of water to convert to ideal gas reference state.