Table 2.

Performance of the model for glaucoma prediction in terms of AUC, Sensitivity, and Specificity, based on three different scenarios: eyes Labeled as glaucoma due to “only optic disc abnormalities”, “optic disc or visual field abnormalities”, and “only visual field abnormalities” (presented as scenario 1, 2, and 3, respectively). P-values identified Based on the method of DeLong. The Significance level is p-value < 0.05

Characteristics AUC (95% CI) Sensitivity (95% CI) Specificity (95% CI) DeLong P-value
Scenario 1 0.90 (0.87 −0.92) 0.83 (0.80–0.86) 0.76 (0.73–0.77) Scenario 1~ Scenario 2: P= 0.32
Scenario 2 0.88 (0.85–0.90) 0.80 (0.77–0.83) 0.73 (0.70–0.75) Scenario 1~ Scenario 3: P= 0.01
Scenario 3 0.80 (0.77–0.82) 0.72 (0.70–0.95) 0.64 (0.61–0.66) Scenario 2~ Scenario 3: P= 0.04