Skip to main content
. Author manuscript; available in PMC: 2025 Mar 1.
Published in final edited form as: Acta Biomater. 2023 Dec 29;176:250–266. doi: 10.1016/j.actbio.2023.12.036

Table 2: Youngs modulus of component hydrogel by sample |.

Measurements taken by AFM and quantified via appropriate Hertz model for sphere-on-sphere contact or sphere-on-surface contact.

Sample of interest Component Fluorescent Tracers Young’s Modulus ± SE
Validation Phantom: AFM PA Inclusions Red, 1–5μm 29.3 ± 2.3 kPa
Phantom Agarose Red, 1–5μm 2.67 ± 0.10 kPa
Reference Hydrogel Green, 1–5μm 7.83 ± 0.25 kPa
Validation Phantom: uElastography, Linear PA inclusions Red, 1–5μm 16.7 ± 1.92kPa
Phantom Agarose Red, 1–5μm 6.1 ± 0.24kPa
Reference Hydrogel Green, 1–5μm 7.6 ± 0.32kPa
Validation Phantom: uElastography, Nonlinear PA inclusions Red, 1–5μm 32.17 ± 5.08kPa
Phantom Agarose Red, 1–5μm 5.97 ± 0.37kPa
Reference Hydrogel Green, 1–5μm 8.41 ± 0.65kPa