Table 2. Adjusted and Unadjusted Treatment Effects of Predictive Tool Use on Willingness for Surgery and Treatment Preference .

Outcome measure OR (95% CI) P value
Willingness for surgery
Unadjusted
Immediate 0.62 (0.35-1.11) .10
6 wk 0.53 (0.29-0.96) .04
12 wk 0.46 (0.25-0.83) .01
6 mo 0.68 (0.38-1.21) .19
Adjusted for baseline difference in willingness for surgery
Immediate 0.70 (0.27-1.81) .46
6 wk 0.58 (0.26-1.29) .18
12 wk 0.52 (0.25-1.10) .09
6 mo 0.85 (0.42-1.71) .64
Treatment preference at 6 mo
Unadjusted
Uncertain 0.34 (0.14-0.77) .01
Prefers surgerya 0.43 (0.22-0.84) .01
Prefers nonsurgical treatmenta 2.31 (1.19-4.49) .01
Adjusted for baseline difference in willingness for surgery
Uncertain 0.36 (0.16-0.76) .009
Prefers surgerya 0.46 (0.20-1.03) .06
Prefers nonsurgical treatmenta 2.16 (0.98-4.92) .06

Abbreviation: OR, odds ratio.

a

If not uncertain about treatment.