Skip to main content
. 2024 Feb 26;24(5):1516. doi: 10.3390/s24051516

Table 2.

Detailed information, specifications, and features of the main RF components and equipment employed in configuring the exposure system.

Equipment Technical Specifications Frequency Range Features, Additional Notes, and Comments
Antenna A-infomw Spot-Focusing Lens Horn Antenna 26–40 GHz Wave guide: WR28
Polarisation: Linear
Signal generator HP 8673B Synthesised signal generator 2–26 GHz Max frequency: 26 GHz
Minimum Frequency: 2 GHz
Modulation: AM-FM-PULSE
Max Output level: 8 dBm
Min output level: −100 dBm
Resolution: 1 kHz
Amplifier MI-WAVE  955 Series Power Amplifier 26.5–31 GHz Gain: 35∼40 dB
Psat output: 43 dBm
Input power for saturated output: 5–10 dBm
Bias: 21 V∼24 V @ 5 A
Input/Output: 2.92 mm(F)
Power meter 1 HP 436A 100 kHz–110 GHz Display readings in Watts, dBm or dB relative eliminating measurement conversion
Peaking meter for analogue adjustments
Cal factor to compensate each sensor for improved accuracy
Power Range: −70 to +44 dBm
Power Accuracy: ±0.5%
Power Reference: Internal 50 MHz oscillator
Type-N output
Power meter 2 HP Agilent Keysight E4416A EPM-P Series Single-Channel Max. Frequency: depends on power sensor Channels: 1
Max. power: depends on power sensor
Measure: Average Peak
IR thermal imaging camera VEVOR (Resolution 240 × 180, 2.8′ Screen, −4 to 662 F temperature range) N/A Thermal sensitivity ≤ 0.04 C