Table 7.

RPCU for each EPC—label design assessed as the EPC 32

EPC Contribution to unreliability
LA label HCD label
2. A shortage of time available for error detection & correction 52% 55%
17. Little or no independent checking or testing of output 14% 15%
39. Distraction/Task Interruption 19% 21%
32. Inconsistency of meaning of displays and procedures 15% 9%