Skip to main content
. 2024 Mar 14;14(13):8779–8789. doi: 10.1039/d3ra08928b

Extract loading and releasing parameters.

Sample LC (%) (calculated from TP) LC (%) (calculated from TA) EE (%) (calculated from TP) EE (%) (calculated from TA) % TP release (pH 7.4 72 h) % TP release (pH 5 72 h) % TA release (pH 7.4 72 h) % TA release (pH 5 72 h)
A1T 5.1 ± 0.3 6.3 ± 0.4 53.7 ± 3.0 67.2 ± 4.0 85.9 ± 0.6 96.0 ± 0.8 46.2 ± 0.7 76.3 ± 0.5
B3T 4.5 ± 0.3 5.4 ± 0.2 47.1 ± 3.0 57.1 ± 2.0 80.7 ± 0.4 91.2 ± 0.6 42.9 ± 0.7 70.2 ± 0.3
C3T 4.7 ± 0.2 5.7 ± 0.3 49.3 ± 2.0 60.4 ± 3.0 78.3 ± 0.4 92.1 ± 0.7 44.3 ± 0.7 67.4 ± 0.2