Skip to main content
. 2023 Aug 14;5:88–98. doi: 10.1109/OJEMB.2023.3304812

TABLE I. State-of-The-Art Analysis of Calorimetric Characterization of Magnetic Scaffolds.

Biomaterial Magnetic Phase Inline graphic (kHz) Inline graphic (mT) Inline graphic (Inline graphicC) Inline graphic (Inline graphicC) Inline graphic (min) Thermometry Medium SAR Ref.
PP Fe Inline graphic OInline graphic 270 3.7 16 - 15 IR Bile duct - [39]
HA Fe Inline graphic OInline graphic, Fe Inline graphic OInline graphic 293 15 35 25 0.5 OF Deionized water - [41]
Gelatin Fe Inline graphic OInline graphic 293 15 17.5 - 1 OF Deionized water - [41]
PCL Fe Inline graphic OInline graphic 293 10 - - 5 OF Deionized water - [41]
PMMA Fe Inline graphic OInline graphic - - 70 25 3 IR Saline - [42]
P Inline graphic OInline graphic-CaO-SiOInline graphic Fe Inline graphic OInline graphic 100 0.5 16 15 16 OF Deionized water 0.2 [43]
CaO-SiO Inline graphic-BzOInline graphic-PInline graphic OInline graphic Fe Inline graphic OInline graphic 100 30 15 32 50 FT Rat Tibia 10 [44]
Ca-SiOInline graphic ZnFe Inline graphic OInline graphic 100 50 27-39 20 3 TC Deionized water 6.5-9 [45]
MBG-PCL Fe Inline graphic OInline graphic 409 18 60-40 20 8-15 OF Deionized water 1.4-4.7 [46]
CaInline graphic(POInline graphic Fe Inline graphic OInline graphic, Fe Inline graphic OInline graphic 335 13.5 12-22.5 26 40 TC Deionized water - [47]
CaInline graphic(POInline graphic Fe Inline graphic OInline graphic 340 10 - - Inline graphic3 IR Air 18.7-30.2 [48]

(FT = Fluoroptic Thermometer, IR = IR Camera, of = Optical Fiber, TC = Thermocouple).