Table 2:
Measured adsorbent capacities of CO2 on 13X zeolite over a range of temperatures and total pressures . Pressure represents the mean of the inlet and outlet pressures with representing the pressure difference between the inlet and outlet of the sorbent column. and are the molar capacities measured by the present apparatus and an independent static adsorption isotherm measurement, respectively, as discussed in the text. The partial pressure of CO2 is 1 % of the total pressure. The relative standard uncertainty for the measurements is 0.05.
| (hPa) | (hPa) | (mol · kg−1) | (mol · kg−1) | |
|---|---|---|---|---|
| 233.1 | 350.5 | 105.7 | 3.47 | |
| 233.1 | 721.2 | 53.1 | 3.93 | |
| 233.1 | 1060.0 | 34.3 | 4.18 | |
| 273.1 | 359.42 | 131.64 | 1.58 | 1.55 |
| 273.1 | 731.1 | 68.9 | 2.04 | 1.95 |
| 273.1 | 1068.3 | 48.4 | 2.19 | 2.17 |
| 298.1 | 358.7 | 143.7 | 0.88 | 0.87 |
| 298.1 | 729.4 | 70.9 | 1.22 | 1.19 |
| 298.1 | 1077.9 | 56.2 | 1.36 | 1.37 |
| 323.1 | 375.4 | 171.4 | 0.41 | 0.42 |
| 323.1 | 743.6 | 89.1 | 0.62 | 0.65 |
| 323.1 | 1068.5 | 57.9 | 0.75 | 0.78 |