Lower limit of quantification (LLOQ) of albendazole sulphoxide (ABZSO), albendazole sulphone (ABZSO2), and albendazole (ABZ), determined in different human biological matrixes: saliva, blood (DBS), and serum.

Matrix ABZSO ABZSO2 ABZ
Saliva LLOQ (µg/mL) 0.01 0.05 0.05
Accuracy (%RE) 10.0 13.0 8.60
Precision (% CV) 5.70 4.70 5.50
DBS LLOQ (µg/mL) 0.1 0.1 0.4
Accuracy (%RE) 13 10.6 8.20
Precision (% CV) 12.6 12.1 10.1
Serum1 LLOQ (µg/mL) 0.025 0.025 0.025
Accuracy (%RE) 10.3 9.30 18.6
Precision (% CV) 3.78 8.46 7.42

1Data reported in Ceballos et al8.

Significant values are in [bold].