Skip to main content
. Author manuscript; available in PMC: 2024 Mar 22.
Published in final edited form as: Int J Radiat Biol. 2023 Mar 22;99(7):1055–1065. doi: 10.1080/09553002.2023.2188933

Figure 2.

Figure 2.

CI-induced miR-34a increases are not different from RI at early time points. B6D2F1 female mice received 9.5 Gy 60Co alone or followed by 15% total body surface area wound trauma (Kiang et al. 2010b). Ileums were collected on days 3, 7, 15 and 30 after RI or CI. No differences between the RI-induced increases in miR-34a and the CI-induced increases in miR-34a were found on days 3, 7, and 15. On day 30, the CI-induced increases were significantly greater than the RI-induced increases (N = 4 per group). *p < .05 vs. respective sham or wound alone; ^p<.05 vs. R-30d using T-Test. miR: microRNA (Kiang et al. 2022 for Materials and Methods). S: Sham; W: 15% total body surface wound; RI: 9.5 Gy; CI: 9.5 Gy + 15% total body surface wound. These results show changes compared to the sham group.