Skip to main content
. 2023 Oct 13;13(2):98–119. doi: 10.1055/s-0043-1775820

Fig. 13.

Fig. 13

( A ) The Abbocath is introduced just over the avulsed fragment. ( B and C ) The loop is captured and taken to the MCR portal, where it is loaded with the first thread. ( D–F ) The loop is recovered to the volar portal along with the first thread, capturing the ulnar portion of the detached ligaments. The first limb of the “U” suture is completed.