Skip to main content
. 2024 Mar 18;15:2439. doi: 10.1038/s41467-024-46681-2

Table 2.

Table of improvement in key performance metrics for likelihood computation using 100-mixture, 3-dimensional density function at 45 nm technology node

Metric Digital Datapath GMT Architecture Improvement
Energy/Likelihood Step 941 pJ 18.33 pJ ~51.3×